Standardization of Operator-Dependent Variables Affecting Precision and Accuracy of the Disk Diffusion Method for Antibiotic Susceptibility Testing
- 1 December 2015
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 53 (12) , 3864-3869
Abstract
Parameters like zone reading, inoculum density, and plate streaking influence the precision and accuracy of disk diffusion antibiotic susceptibility testing (AST). While improved reading precision has been demonstrated using automated imaging systems, standardization of the inoculum and of plate streaking have not been systematically investigated yet. This study analyzed whether photometrically controlled inoculum preparation and/or automated inoculation could further improve the standardization of disk diffusion. Suspensions of Escherichia coli ATCC 25922 and Staphylococcus aureus ATCC 29213 of 0.5 McFarland standard were prepared by 10 operators using both visual comparison to turbidity standards and a Densichek photometer (bioMérieux), and the resulting CFU counts were determined. Furthermore, eight experienced operators each inoculated 10 Mueller-Hinton agar plates using a single 0.5 McFarland standard bacterial suspension of E. coli ATCC 25922 using regular cotton swabs, dry flocked swabs (Copan, Brescia, Italy), or an automated streaking device (BD-Kiestra, Drachten, Netherlands). The mean CFU counts obtained from 0.5 McFarland standard E. coli ATCC 25922 suspensions were significantly different for suspensions prepared by eye and by Densichek ( P < 0.001). Preparation by eye resulted in counts that were closer to the CLSI/EUCAST target of 10 8 CFU/ml than those resulting from Densichek preparation. No significant differences in the standard deviations of the CFU counts were observed. The interoperator differences in standard deviations when dry flocked swabs were used decreased significantly compared to the differences when regular cotton swabs were used, whereas the mean of the standard deviations of all operators together was not significantly altered. In contrast, automated streaking significantly reduced both interoperator differences, i.e., the individual standard deviations, compared to the standard deviations for the manual method, and the mean of the standard deviations of all operators together, i.e., total methodological variation.Keywords
This publication has 12 references indexed in Scilit:
- Relative contribution of biological variation and technical variables to zone diameter variations of disc diffusion susceptibility testingJournal of Antimicrobial Chemotherapy, 2015
- Integrating Forecast Probabilities in Antibiograms: a Way To Guide Antimicrobial Prescriptions More Reliably?Journal of Clinical Microbiology, 2014
- Point-Counterpoint: The Automated Clinical Microbiology Laboratory: Fact or Fantasy?Journal of Clinical Microbiology, 2014
- Automation in Clinical MicrobiologyJournal of Clinical Microbiology, 2013
- The critical influence of the intermediate category on interpretation errors in revised EUCAST and CLSI antimicrobial susceptibility testing guidelinesClinical Microbiology and Infection, 2013
- Standardisation of disk diffusion results for antibiotic susceptibility testing using the sirscan automated zone readerBMC Microbiology, 2013
- Automation in clinical bacteriology: what system to choose?Clinical Microbiology and Infection, 2011
- Antibiotic sensitivity testing. Report of an international collaborative study.1971
- Antibiotic susceptibility testing by a standardized single disk method.1966
- Antibiotic Susceptibility Testing by a Standardized Single Disk MethodAmerican Journal of Clinical Pathology, 1966