Abstract
As indispensable components in the global transition toward carbon neutrality, lithium-ion batteries face growing scrutiny due to recurring safety concerns that threaten to undermine their sustainable development. Internal gas pressure serves as a crucial diagnostic indicator in electrochemical diagnosis, enabling precise characterization of degradation mechanisms and state-of-health (SOH) evaluation in advanced battery architectures. Here, we propose a non-invasive in situ diagnostic method for monitoring time-resolved internal pressure (0.01 kPa instrument-limited, 0.027 kPa (3σ) noise-limited resolution) and temperature (±0.5 K accuracy) simultaneously by attaching fiber Bragg grating (FBG) sensors to the surface of an 18650 commercial lithium-ion battery. We further develop a pressure-temperature interdependency model that comprehensively considers the ideal gas law, electrode lithiation and gas sorption dynamics for predicting gas pressure within a battery with an error below 1.69%. During battery overcharging at 0.5C in 2 h 26 min, we observe a gas accumulation rate of 1.77 mol/(m3·h) mainly due to irreversible reactions within a battery, which is around 800 times higher than that in normal charge and discharge cycles. The results indicate that the proposed technique shows strong potential for achieving gas evolution analysis and battery health estimation.
Funding Information
  • Yunnan Key Research and Development Program (2023YFE0120900)
  • Nationally Funded Postdoctoral Researcher Program (GZC20230045)
  • State Key Laboratory of Advanced Electromagnetic Engineering and Technology (2025KF009)

This publication has 35 references indexed in Scilit: