Hao Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hao Liu has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Guoming Ma
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
10 shared publications - Weiqi Qin
Department of Electrical Engineering, Tsinghua University, Beijing 100084, China
6 shared publications - Houxian Du
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources and Beijing Key Laboratory of High Voltage and EMC, North China Electric Power University, Beijing, China
3 shared publications - Sihan Wang
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
3 shared publications Wei Wang
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
3 shared publications- Yuan Wang
College of Engineering, Peking University, Beijing, China
3 shared publications
Latest Publications
- 26 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-9
Cylindrical Battery Gas Evolution Analysis via Optical Fiber Based Noninvasive Gas Pressure Monitoring
As indispensable components in the global transition toward carbon neutrality, lithium-ion batteries face growing scrutiny due to recurring safety concerns that threaten to undermine their sustainable development. Internal gas pressure serves as a crucial diagnostic indicator in electrochemical diagnosis, enabling precise characterization of degradation mechanisms and state-of-health (SOH) evaluation in advanced battery architectures. Here, we propose a non-invasive in situ diagnostic method for monitoring time-resolved internal pressure (0.01 kPa instrument-limited, 0.027 kPa (3σ) noise-limited resolution) and temperature (±0.5 K accuracy) simultaneously by attaching fiber Bragg grating (FBG) sensors to the surface of an 18650 commercial lithium-ion battery. We further develop a pressure-temperature interdependency model that comprehensively considers the ideal gas law, electrode lithiation and gas sorption dynamics for predicting gas pressure within a battery with an error below 1.69%. During battery overcharging at 0.5C in 2 h 26 min, we observe a gas accumulation rate of 1.77 mol/(m3·h) mainly due to irreversible reactions within a battery, which is around 800 times higher than that in normal charge and discharge cycles. The results indicate that the proposed technique shows strong potential for achieving gas evolution analysis and battery health estimation.
- 26 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-9
Cylindrical Battery Gas Evolution Analysis via Optical Fiber Based Noninvasive Gas Pressure Monitoring
As indispensable components in the global transition toward carbon neutrality, lithium-ion batteries face growing scrutiny due to recurring safety concerns that threaten to undermine their sustainable development. Internal gas pressure serves as a crucial diagnostic indicator in electrochemical diagnosis, enabling precise characterization of degradation mechanisms and state-of-health (SOH) evaluation in advanced battery architectures. Here, we propose a non-invasive in situ diagnostic method for monitoring time-resolved internal pressure (0.01 kPa instrument-limited, 0.027 kPa (3σ) noise-limited resolution) and temperature (±0.5 K accuracy) simultaneously by attaching fiber Bragg grating (FBG) sensors to the surface of an 18650 commercial lithium-ion battery. We further develop a pressure-temperature interdependency model that comprehensively considers the ideal gas law, electrode lithiation and gas sorption dynamics for predicting gas pressure within a battery with an error below 1.69%. During battery overcharging at 0.5C in 2 h 26 min, we observe a gas accumulation rate of 1.77 mol/(m3·h) mainly due to irreversible reactions within a battery, which is around 800 times higher than that in normal charge and discharge cycles. The results indicate that the proposed technique shows strong potential for achieving gas evolution analysis and battery health estimation.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75, 9538710
High-Sensitivity Partial Discharge Detection in Cable Joints Over Long Distances Based on Chirped Phase-Sensitive Optical Time-Domain Reflectometry
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75, 9538710
High-Sensitivity Partial Discharge Detection in Cable Joints Over Long Distances Based on Chirped Phase-Sensitive Optical Time-Domain Reflectometry
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (15) , 1
A Gold Diaphragm Fabry–Pérot Fiber-Optic Ultrasonic Sensor for Partial Discharge Detection in Transformer Oil
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (15) , 1
A Gold Diaphragm Fabry–Pérot Fiber-Optic Ultrasonic Sensor for Partial Discharge Detection in Transformer Oil
- 29 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (2) , 3288-3294
A Dual-Function Measurement System for Detection of Very Fast Transient and Partial Discharge
The measurements of very fast transient (VFT) in power systems are crucial for fault analysis and location, especially in gas-insulated switchgear (GIS). However, most of the existing GIS is not equipped with the built-in VFT sensor. In China, the ultra-high frequency (UHF) sensor has been widely installed in GIS. This paper presents a dual-function measurement system designed for detecting VFT and partial discharge (PD) using an UHF sensor. In laboratory amplitude-frequency response tests, the bandwidth of VFT measurement channel was calibrated to range from 0.27 Hz to 90.29 MHz. The UHF sensor can be used as a PD sensor after the VFT measurement, and the sensing characters of PD are not affected by the VFT measurement channel. In practical application, this system was installed in a 500 kV pumped storage power plant. The switching transient voltages during breaker switching operations were successfully measured with a built-in UHF sensor. The maximum overvoltage was found to be 1.40 p.u. This dual-function measurement system provides great potential for accurately measuring VFT without the need for additional sensor installation, which is particularly practical and convenient for already operational GIS substations.
- 29 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (2) , 3288-3294
A Dual-Function Measurement System for Detection of Very Fast Transient and Partial Discharge
The measurements of very fast transient (VFT) in power systems are crucial for fault analysis and location, especially in gas-insulated switchgear (GIS). However, most of the existing GIS is not equipped with the built-in VFT sensor. In China, the ultra-high frequency (UHF) sensor has been widely installed in GIS. This paper presents a dual-function measurement system designed for detecting VFT and partial discharge (PD) using an UHF sensor. In laboratory amplitude-frequency response tests, the bandwidth of VFT measurement channel was calibrated to range from 0.27 Hz to 90.29 MHz. The UHF sensor can be used as a PD sensor after the VFT measurement, and the sensing characters of PD are not affected by the VFT measurement channel. In practical application, this system was installed in a 500 kV pumped storage power plant. The switching transient voltages during breaker switching operations were successfully measured with a built-in UHF sensor. The maximum overvoltage was found to be 1.40 p.u. This dual-function measurement system provides great potential for accurately measuring VFT without the need for additional sensor installation, which is particularly practical and convenient for already operational GIS substations.
- 15 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (1) , 20-27
Acoustic Emission and Propagation Characteristics of Metal Particles in GIS
Metal particle pollution was one of the significant factors that endangerd the reliability of the gas insulated switchgears (GIS). The detection of metal particles in GIS was crucial for ensuring the safe operation of GIS. This paper established a calculation model for the cut-off frequency of acoustic emission (AE) generated by the metal particle collision with the GIS enclosure. The effects of metal particle materials, the Gaussian equivalent radius, and the bounce heights on the cut-off frequency of the acoustic emission signal were obtained. Through the acoustic emission measurement experiments of metal particle colliding with an aluminum plate, the accuracy of the cut-off frequency calculation model was verified. Besides, the experiment confirmed that the propagation mode of the acoustic emission signal on GIS enclosure was primarily the S0 mode Lamb wave. The attenuation of the AE signal was analyzed. The geometric attenuation and the energy loss attenuation were determined as the primary attenuation processes. A calculation model for the attenuation of acoustic emission signal was established. Based on this, the variation of the cut-off frequency after propagation on the GIS enclosure was clarified. The acoustic emission and propagation characteristic proposed in this paper provided guidance for optimizing the frequency band of ultrasonic sensors and setting up the measurement points.
- 15 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (1) , 20-27
Acoustic Emission and Propagation Characteristics of Metal Particles in GIS
Metal particle pollution was one of the significant factors that endangerd the reliability of the gas insulated switchgears (GIS). The detection of metal particles in GIS was crucial for ensuring the safe operation of GIS. This paper established a calculation model for the cut-off frequency of acoustic emission (AE) generated by the metal particle collision with the GIS enclosure. The effects of metal particle materials, the Gaussian equivalent radius, and the bounce heights on the cut-off frequency of the acoustic emission signal were obtained. Through the acoustic emission measurement experiments of metal particle colliding with an aluminum plate, the accuracy of the cut-off frequency calculation model was verified. Besides, the experiment confirmed that the propagation mode of the acoustic emission signal on GIS enclosure was primarily the S0 mode Lamb wave. The attenuation of the AE signal was analyzed. The geometric attenuation and the energy loss attenuation were determined as the primary attenuation processes. A calculation model for the attenuation of acoustic emission signal was established. Based on this, the variation of the cut-off frequency after propagation on the GIS enclosure was clarified. The acoustic emission and propagation characteristic proposed in this paper provided guidance for optimizing the frequency band of ultrasonic sensors and setting up the measurement points.
- 26 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Improving SNR and Sensing Distance of COTDR for Distributed Partial Discharge Detection in Power Cable Joints
Distributed detection of partial discharge (PD) in joints of long power cables is both a necessity and a challenge. In order to improve the distance and sensitivity of PD detection, an improved coherent optical time domain reflectometer (COTDR) system is proposed in this paper. A two-stage optical amplification scheme was established, and the pump currents of erbium-doped fiber amplifiers (EDFAs) were optimized to improve the signal-to-noise ratio (SNR) of the beat signal. The dual-frequency probe pulses were introduced to suppress fading noises in the distance-domain and prevent false positives in PD detection. The test results based on real cable joints indicated that the system enabled distributed detection and accurate waveform retrieval of PD events. Based on the above improvements, the proposed system enhanced the PD sensing performance from the existing 1 km sensing distance and nC-level detection limit to 20 km and 127 pC, respectively. This performance indicated that the COTDR system possessed practicality in the distributed detection of cable joints PDs.
- 26 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Improving SNR and Sensing Distance of COTDR for Distributed Partial Discharge Detection in Power Cable Joints
Distributed detection of partial discharge (PD) in joints of long power cables is both a necessity and a challenge. In order to improve the distance and sensitivity of PD detection, an improved coherent optical time domain reflectometer (COTDR) system is proposed in this paper. A two-stage optical amplification scheme was established, and the pump currents of erbium-doped fiber amplifiers (EDFAs) were optimized to improve the signal-to-noise ratio (SNR) of the beat signal. The dual-frequency probe pulses were introduced to suppress fading noises in the distance-domain and prevent false positives in PD detection. The test results based on real cable joints indicated that the system enabled distributed detection and accurate waveform retrieval of PD events. Based on the above improvements, the proposed system enhanced the PD sensing performance from the existing 1 km sensing distance and nC-level detection limit to 20 km and 127 pC, respectively. This performance indicated that the COTDR system possessed practicality in the distributed detection of cable joints PDs.
- 25 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-8
Fast Transient Measurement at Transformer Terminal Based on Built-In Capacitive Sensor
It is important to determine the transient stresses at large power transformer winding terminals, because this transient stress may induce power transformer failure. When a transient sensor is mounted inside the transformer, there is a potential discharge from the high-voltage conductor to the sensor. Therefore, the transient voltages in transformers are usually measured indirectly. Such measurement results are not accurate because they are affected by the structure and impedance of the power equipment. Thus, a built-in capacitive fast transient sensor was developed in this paper. The developed sensor was installed inside the bushing mounting; thus, transient voltages are directly obtained. To eliminate potential discharge from a high-voltage conductor to a transient sensor, a dielectric window (DW) was developed. Then, the effects of the dielectric window and transformer oil on the amplitude-frequency response of the sensor were investigated. The results indicate that the bandwidth of the developed sensor spans 11 Hz~86.6 MHz (±1 dB). Afterward, switching and lightning impulse tests were conducted to demonstrate the accuracy of the sensor. Moreover, the proposed sensor was used to investigate the transient overvoltage in a 500 kV pumped storage power plant. The transformer winding exhibits increased stress due to the influence of frequent resonant transients with high amplitudes.
- 25 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-8
Fast Transient Measurement at Transformer Terminal Based on Built-In Capacitive Sensor
It is important to determine the transient stresses at large power transformer winding terminals, because this transient stress may induce power transformer failure. When a transient sensor is mounted inside the transformer, there is a potential discharge from the high-voltage conductor to the sensor. Therefore, the transient voltages in transformers are usually measured indirectly. Such measurement results are not accurate because they are affected by the structure and impedance of the power equipment. Thus, a built-in capacitive fast transient sensor was developed in this paper. The developed sensor was installed inside the bushing mounting; thus, transient voltages are directly obtained. To eliminate potential discharge from a high-voltage conductor to a transient sensor, a dielectric window (DW) was developed. Then, the effects of the dielectric window and transformer oil on the amplitude-frequency response of the sensor were investigated. The results indicate that the bandwidth of the developed sensor spans 11 Hz~86.6 MHz (±1 dB). Afterward, switching and lightning impulse tests were conducted to demonstrate the accuracy of the sensor. Moreover, the proposed sensor was used to investigate the transient overvoltage in a 500 kV pumped storage power plant. The transformer winding exhibits increased stress due to the influence of frequent resonant transients with high amplitudes.
- 13 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
Low Cut-Off Frequency Extension and Amplitude Decoupling Analysis in Non-Contact Transient Measurement
For the non-contact measurement system, the low frequency measuring and uncertainty analyzing are critical to obtain the accurate amplitude of the transient overvoltage. In this paper, the circuit parameters that affect the low cut-off frequency of the measurement system were analyzed. Then, based on impedance converter, the ±1 dB low cut-off frequency was reduced from 9.8 Hz to 0.25 Hz. Moreover, the transient overvoltage generated by the air insulated disconnector operation in the 500 kV AC switchyard of a ±800 kV high-voltage direct current (HVDC) converter station was measured by the developed system. The time and frequency domain characteristic of the transient overvoltage was obtained. The measured three-phase transient overvoltage voltages were recovered using the decoupling matrix. The uncertainty analysis was carried out based on the field waveforms. After that, the impacts of average times and voltage step amplitudes on the uncertainty was compared. And the optimal average number of times is 10 and the voltage step amplitude selection should be greater than 0.5 p.u. The analysis results indicated that the measurement uncertainties for both high-frequency overvoltage and power frequency are below 10%.
- 13 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
Low Cut-Off Frequency Extension and Amplitude Decoupling Analysis in Non-Contact Transient Measurement
For the non-contact measurement system, the low frequency measuring and uncertainty analyzing are critical to obtain the accurate amplitude of the transient overvoltage. In this paper, the circuit parameters that affect the low cut-off frequency of the measurement system were analyzed. Then, based on impedance converter, the ±1 dB low cut-off frequency was reduced from 9.8 Hz to 0.25 Hz. Moreover, the transient overvoltage generated by the air insulated disconnector operation in the 500 kV AC switchyard of a ±800 kV high-voltage direct current (HVDC) converter station was measured by the developed system. The time and frequency domain characteristic of the transient overvoltage was obtained. The measured three-phase transient overvoltage voltages were recovered using the decoupling matrix. The uncertainty analysis was carried out based on the field waveforms. After that, the impacts of average times and voltage step amplitudes on the uncertainty was compared. And the optimal average number of times is 10 and the voltage step amplitude selection should be greater than 0.5 p.u. The analysis results indicated that the measurement uncertainties for both high-frequency overvoltage and power frequency are below 10%.
- Open Access
- 2 December 2022
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 8 (2) , 412-420
A low‐cost and high‐performance self‐trigger method for high‐voltage transient measurement
Stable triggering of acquisition devices is critical to accurately measure electromagnetic transients, especially for very fast transient overvoltages (VFTOs). A highly stable and low‐cos t self‐trigger method for transient measurement is proposed. An integrated low‐voltage arm module was developed to synchronously realise the triggering and VFTO measurement. The trigger branch was developed using a high‐pass filter. This component obtained the high‐frequency component of the VFTO to trigger the oscilloscope. The trigger branch was integrated with the measurement branch through an impedance converter. An attenuator was implemented before the impedance converter to avoid overvoltage damage to the chip. The circuit parameters of the attenuator were optimised to alleviate the disturbance of the measurement branch. The calibration results demonstrated that the ±1 dB bandwidth of the measurement branch in this system ranged from 11.8 Hz to 105 MHz. The low cutoff frequency of the trigger branch was 710 Hz. The VFTO waveforms generated by the operation of a disconnector in a real 252 kV gas insulated switchgear were measured using the proposed system. The test results verified that the self‐trigger measurement system can provide stable trigger signals and accurately measure the VFTO waveforms.
- 2 December 2022
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 8 (2) , 412-420
Open AccessA low‐cost and high‐performance self‐trigger method for high‐voltage transient measurement
Stable triggering of acquisition devices is critical to accurately measure electromagnetic transients, especially for very fast transient overvoltages (VFTOs). A highly stable and low‐cos t self‐trigger method for transient measurement is proposed. An integrated low‐voltage arm module was developed to synchronously realise the triggering and VFTO measurement. The trigger branch was developed using a high‐pass filter. This component obtained the high‐frequency component of the VFTO to trigger the oscilloscope. The trigger branch was integrated with the measurement branch through an impedance converter. An attenuator was implemented before the impedance converter to avoid overvoltage damage to the chip. The circuit parameters of the attenuator were optimised to alleviate the disturbance of the measurement branch. The calibration results demonstrated that the ±1 dB bandwidth of the measurement branch in this system ranged from 11.8 Hz to 105 MHz. The low cutoff frequency of the trigger branch was 710 Hz. The VFTO waveforms generated by the operation of a disconnector in a real 252 kV gas insulated switchgear were measured using the proposed system. The test results verified that the self‐trigger measurement system can provide stable trigger signals and accurately measure the VFTO waveforms.