Depiction Fidelity and Specificity in Direct MRI of Collagen: Addressing Signal Decay at the Microsecond Timescale
Open Access
- 11 October 2026
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
Abstract
Purpose: Gap‐filled zero echo time (ZTE) acquisitions combined with dedicated short‐ T 2 hardware enable direct collagen imaging on the timescale of macromolecular (MM) signals, with T 2 s ˜ 10 μs. However, present methods offer limited depiction fidelity, and their specificity towards MM content is poorly understood. This work presents methodology to improve depiction fidelity of MM signals and investigates how imaging parameters influence MM specificity. Methods: 1D simulations of gap‐filled ZTE sequences acquiring MM signals are used to evaluate depiction fidelity and specificity via the modulation transfer function (MTF) and point spread function (PSF). Insights are used to address signal decay at the microsecond timescale by (i) modifying the k‐space sampling pattern through gap filling with MTF smoothing, (ii) selecting acquisition parameters that optimize MM specificity and (iii) designing a post‐processing filter to improve resolution. The approaches are demonstrated with 3D imaging simulations and experiments. Results: Gap‐filled ZTE with specialized hardware targets MM signals but enters a unique imaging regime where depiction fidelity is limited: the PSF exhibits a broad main lobe from T 2 blurring and far‐reaching side lobes caused by a kink in the k‐space sampling pattern. The latter is addressed through MTF smoothing. MM specificity is then maximized by subtracting two images acquired at different times but maintaining imaging bandwidth. Finally, post‐processing filters narrow MM PSF main lobe, reducing T 2 blurring and improving depiction fidelity. Conclusion: The investigation and developed methods improve collagen MM imaging, with potential applications for in vivo imaging or assessing materials that exhibit decay on MM timescales.Keywords
This publication has 46 references indexed in Scilit:
- Improved cortical bone specificity in UTE MR ImagingMagnetic Resonance in Medicine, 2016
- Exploring the bandwidth limits of ZTE imaging: Spatial response, out‐of‐band signals, and noise propagationMagnetic Resonance in Medicine, 2014
- Deuterium nuclear magnetic resonance unambiguously quantifies pore and collagen-bound water in cortical boneJournal of Bone and Mineral Research, 2012
- Comparison of optimized soft‐tissue suppression schemes for ultrashort echo time MRIMagnetic Resonance in Medicine, 2011
- Ultrashort echo time imaging using pointwise encoding time reduction with radial acquisition (PETRA)Magnetic Resonance in Medicine, 2011
- RF coil considerations for short‐T2 MRIMagnetic Resonance in Medicine, 2010
- Characterization of 1H NMR signal in human cortical bone for magnetic resonance imagingMagnetic Resonance in Medicine, 2010
- Collagen‐Targeted MRI Contrast Agent for Molecular Imaging of FibrosisAngewandte Chemie International Edition, 2007
- Water‐ and fat‐suppressed proton projection MRI (WASPI) of rat femur boneMagnetic Resonance in Medicine, 2007
- Three‐dimensional radial ultrashort echo‐time imaging with T2 adapted samplingMagnetic Resonance in Medicine, 2006