Latest Publications

  • Open Access

    Depiction Fidelity and Specificity in Direct MRI of Collagen: Addressing Signal Decay at the Microsecond Timescale

    by Jason Daniel van Schoor, Markus Weiger, Emily Louise Baadsvik, Klaas Paul Pruessmann

    Purpose: Gap‐filled zero echo time (ZTE) acquisitions combined with dedicated short‐ T 2 hardware enable direct collagen imaging on the timescale of macromolecular (MM) signals, with T 2 s ˜ 10 μs. However, present methods offer limited depiction fidelity, and their specificity towards MM content is poorly understood. This work presents methodology to improve depiction fidelity of MM signals and investigates how imaging parameters influence MM specificity. Methods: 1D simulations of gap‐filled ZTE sequences acquiring MM signals are used to evaluate depiction fidelity and specificity via the modulation transfer function (MTF) and point spread function (PSF). Insights are used to address signal decay at the microsecond timescale by (i) modifying the k‐space sampling pattern through gap filling with MTF smoothing, (ii) selecting acquisition parameters that optimize MM specificity and (iii) designing a post‐processing filter to improve resolution. The approaches are demonstrated with 3D imaging simulations and experiments. Results: Gap‐filled ZTE with specialized hardware targets MM signals but enters a unique imaging regime where depiction fidelity is limited: the PSF exhibits a broad main lobe from T 2 blurring and far‐reaching side lobes caused by a kink in the k‐space sampling pattern. The latter is addressed through MTF smoothing. MM specificity is then maximized by subtracting two images acquired at different times but maintaining imaging bandwidth. Finally, post‐processing filters narrow MM PSF main lobe, reducing T 2 blurring and improving depiction fidelity. Conclusion: The investigation and developed methods improve collagen MM imaging, with potential applications for in vivo imaging or assessing materials that exhibit decay on MM timescales.

  • Open Access

    Direct MRI of collagen

    by Jason Daniel Van Schoor, Markus Weiger, Emily Louise Baadsvik, Klaas P Pruessmann

    Collagen is the most abundant protein in the human body and has an important role in healthy tissue as well as in a range of prevalent diseases. Medical research and diagnostics, hence, call for means of mapping collagen in vivo. Magnetic resonance imaging (MRI) is a natural candidate for this task, offering full 3D capability and versatile contrast non-invasively. However, collagen has so far been invisible to MRI due to extremely short lifetime of its resonances. Here, we report the direct imaging of collagen in vivo by magnetic resonance on the microsecond scale. The dynamics of resonance signals from collagen were first assessed in samples of bovine tendon and cortical bone. On this basis, imaging was performed at echo times down to 10 microseconds, yielding collagen-specific depiction by echo subtraction. The same approach was then extended for use in vivo, enabling direct collagen imaging of a human forearm. This capability suggests significant promise for biomedical science and clinical use.

  • Open Access

    Direct MRI of Collagen

    by Jason D van Schoor, Markus Weiger, Emily Louise Baadsvik, Klaas P Pruessmann

    Collagen is the most abundant protein in the human body and has an important role in healthy tissue as well as in a range of prevalent diseases. Medical research and diagnostics hence call for means of mapping collagen in vivo. Magnetic resonance imaging (MRI) is a natural candidate for this task, offering full 3D capability and versatile contrast non-invasively. However, collagen has so far been invisible to MRI due to extremely short lifetime of its resonances. Here, we report the direct imaging of collagen in vivo by magnetic resonance on the microsecond scale. The dynamics of resonance signals from collagen were first assessed in samples of bovine tendon and cortical bone. On this basis, imaging was performed at echo times down to 10 microseconds, yielding collagen-specific depiction by echo subtraction. The same approach was then extended for use in vivo, enabling direct collagen imaging of a human forearm. This capability suggests significant promise for biomedical science and clinical use.

  • Open Access

    Making RF coils MR ‐invisible by additive manufacturing using magnetically filled polymer

    by Markus Weiger, Johan Overweg, Amelie Viol, Lauro Singenberger, Thomas Schmid, Emily Louise Baadsvik, Klaas Paul Pruessmann

    Purpose: Short‐T 2 MRI is sensitive not only to targeted tissues but also to signals from materials in RF coils, which can lead to image background artifacts. Current solutions to this problem either compromise imaging performance or impose restrictions on coil design. The goal of the present work is to make RF coils MR‐invisible without such drawbacks. Methods: Effective spoiling of unwanted signals from the housing of RF coils is achieved by filling the material used to construct the housing with magnetic particles. This concept is demonstrated by creating coil formers through additive manufacturing with custom filaments made from magnetite‐filled polymer. Results: Unwanted signals from the RF coil are effectively eliminated by using coil formers made from magnetically filled polymer. In this fashion, background‐free short‐T 2 imaging is enabled. Conclusion: Making RF coils MR‐invisible by using magnetically filled materials simplifies coil design and manufacturing and renders the alteration of MR sequences unnecessary, thereby improving the performance of MRI of tissues with short T 2 s.


  • Open Access

    Making RF coils MR‐invisible by additive manufacturing using magnetically filled polymer

    by Markus Weiger, Johan Overweg, Amelie Viol, Lauro Singenberger, Thomas Schmid, Emily Louise Baadsvik, Klaas Paul Pruessmann

    Purpose: Short‐T2 MRI is sensitive not only to targeted tissues but also to signals from materials in RF coils, which can lead to image background artifacts. Current solutions to this problem either compromise imaging performance or impose restrictions on coil design. The goal of the present work is to make RF coils MR‐invisible without such drawbacks.Methods: Effective spoiling of unwanted signals from the housing of RF coils is achieved by filling the material used to construct the housing with magnetic particles. This concept is demonstrated by creating coil formers through additive manufacturing with custom filaments made from magnetite‐filled polymer.Results: Unwanted signals from the RF coil are effectively eliminated by using coil formers made from magnetically filled polymer. In this fashion, background‐free short‐T2 imaging is enabled.Conclusion: Making RF coils MR‐invisible by using magnetically filled materials simplifies coil design and manufacturing and renders the alteration of MR sequences unnecessary, thereby improving the performance of MRI of tissues with short T2s.

  • Open Access

    A unipolar head gradient for high‐field MRI without encoding ambiguity

    by Markus Weiger, Johan Overweg, Franciszek Hennel, Emily Louise Baadsvik, Samuel Bianchi, Oskar Björkqvist, Roger Luechinger, Jens Metzger, Eric Seth Michael, Thomas Schmid, et al.

    Purpose: MRI gradients with a conventional, bipolar design generally face a trade‐off among performance, encoding ambiguity, and radiofrequency selectivity used to circumvent said ambiguity. This problem is particularly limiting in cutting‐edge brain imaging performed at field strengths ≥ 7 T and using high‐performance head gradients. Methods: To address this issue, the present work proposes to fundamentally eliminate the encoding ambiguity in head gradients by using a unipolar z‐gradient design that takes advantage of the signal‐free range on one side of the imaging volume. This concept is demonstrated by implementation of a unipolar head gradient for operation at 7 T . Results: Imaging in phantoms and in vivo demonstrates elimination of backfolding due to encoding ambiguity. At the same time, the unipolar design achieves efficiency on par with conventional bipolar design, resulting in high amplitude and slew‐rate performance. Conclusion: The prospect of gradient systems based on a unipolar design holds promise for all advanced neuroimaging that demands high gradient performance. It will make the greatest difference at 7 T and beyond, where the absence of ambiguity removes a key concern and constraint in terms of radiofrequency behavior and instrumentation.


  • Open Access

    A unipolar head gradient for high-field MRI without encoding ambiguity

    by Markus Weiger, Johan Overweg, Franciszek Hennel, Emily Louise Baadsvik, Samuel Bianchi, Oskar Björkqvist, Roger Luechinger, Jens Metzger, Eric Michael, Thomas Schmid, et al.

    Purpose: MRI gradients with a conventional, bipolar design generally face a trade-off between performance, encoding ambiguity, and circumventing the latter by means of RF selectivity. This problem is particularly limiting in cutting-edge brain imaging performed at field strengths >= 7T and using high-performance head gradients. Methods: To address this issue, the present work proposes to fundamentally eliminate the encoding ambiguity in head gradients by using a unipolar z-gradient design that takes advantage of the signal-free range on one side of the imaging volume. This concept is demonstrated by implementation of a unipolar head gradient for operation at 7T. Results: Imaging in phantoms and in vivo demonstrates elimination of backfolding due to encoding ambiguity. At the same time, the unipolar design achieves efficiency on par with conventional bipolar design, resulting in high amplitude and slew-rate performance. Conclusion: The prospect of gradient systems based on a unipolar design holds promise for all advanced neuroimaging that demands high gradient performance. It will make the greatest difference at 7T and beyond where the absence of ambiguity removes a key concern and constraint in terms of RF behaviour and instrumentation.

  • Open Access

    Quantitative magnetic resonance mapping of the myelin bilayer reflects pathology in multiple sclerosis brain tissue

    by Emily Louise Baadsvik, Markus Weiger, Romain Froidevaux, Wolfgang Faigle, Benjamin V. Ineichen, Klaas P. Pruessmann

    Multiple sclerosis (MS) is a neuroinflammatory disease characterized by loss of myelin (demyelination) and, to a certain extent, subsequent myelin repair (remyelination). To better understand the pathomechanisms underlying de- and remyelination and to monitor the efficacy of treatments aimed at regenerating myelin, techniques offering noninvasive visualizations of myelin are warranted. Magnetic resonance (MR) imaging has long been at the forefront of efforts to visualize myelin, but it has only recently become feasible to access the rapidly decaying resonance signals stemming from the myelin lipid-protein bilayer itself. Here, we show that direct MR mapping of the bilayer yields highly specific myelin maps in brain tissue from patients with MS. Furthermore, examination of the bilayer signal behavior is found to reveal pathological alterations in normal-appearing white and gray matter. These results indicate promise for in vivo implementations of the myelin bilayer mapping technique, with prospective applications in basic research, diagnostics, disease monitoring, and drug development.


  • Myelin Bilayer Imaging

    by Emily Louise Baadsvik, Markus Weiger

  • Zero Echo Time (ZTE) MRI

    by Markus Weiger, Klaas P. Pruessmann