Three-dimensional assessment of toroidal heat-load distribution on divertor targets in EAST

Authors:

Abstract
Although actively cooled W/Cu monoblock targets are designed for high steady-state heat exhaust, local overheating and damage have been observed on these targets in EAST. These observations suggest that, beyond the nominal heat-removal capability, the practical thermal margin may be compromised by engineering alignment, target geometry and plasma operating conditions—all of which can alter the local surface-normal heat flux via modifications in magnetic incidence and magnetic shadowing. In this work, the toroidal distribution of the heat loads on the EAST divertor is analyzed by integrating infrared thermography, finite element heat flux inversion, and three-dimensional field-line tracing using PFCFlux. This analysis focuses on the effects of toroidal-field ripple, cassette misalignment in the presence of ripple, and divertor geometry. It is shown that the 16-fold toroidal field ripple can produce a 2 π / 16 modulation of the peak heat flux on the current upper outer divertor target, with a peak fluctuation amplitude of approximately 17.75 % . Under a peak heat flux constraint of Q safe = 10  MW  m − 2 , the allowable average heat flux on the upper outer target (OT) decreases from 4.28   MW   m − 2 in the absence of ripple to 3.94   MW   m − 2 in the presence of ripple. When ripple and relative cassette misalignments are considered simultaneously for the same target, the allowable average heat flux is further reduced to 3.11 MW   m − 2 , 2.79 MW   m − 2 , and 2.27   MW   m − 2 for Δ = 0.6 mm , 1.0 mm , and 3.0   mm , respectively. Compared with the present upper OT, the toroidally curved lower outer vertical target (OVT) has higher allowable average heat fluxes under both ripple-free and ripple conditions without cassette misalignment, with values of 7.00 and 5.98 MW   m − 2 , respectively, compared with 4.28 and 3.94 MW   m − 2 for the upper OT. Undertoroidal-field ripple and a Δ = 1   mm misalignment, the new upper horizontal target achieves a higher allowable average heat flux than the lower outer horizontal target (OHT), with values of 4.70 and 4.01 MW   m − 2 , respectively. These results show that magnetic ripple, assembly tolerances, and toroidal geometric continuity must be considered in the thermal design of divertor targets in fusion devices.
Funding Information
  • Natural Science Foundation of Anhui Province (2508085J007)
  • National Natural Science Foundation of China (12205332)
  • Anhui Provincial Major Science and Technology Project (2023z020004)
  • National Key Research and Development Program of China (2022YFE03030000)
  • Strategic Priority Research Program of Chinese Academy of Sciences (XDB0790103)
  • CASHIPS Director’s Fund (JPY2023A03)

This publication has 42 references indexed in Scilit: