Background/Aims: This study investigates the use of blood volume monitoring (BVM) markers for the assessment of fluid status. Methods: Predialysis fluid overload (FO) and BVM data were collected in 55 chronic hemodialysis patients in 317 treatments. Predialysis FO was measured using bioimpedance spectroscopy. The slope of the intravascular volume decrease over time normalized by ultrafiltration rate (Slope4h) was used as the primary BVM marker and compared against FO. Results: Average relative blood volume curves were well separated in different FO groups between 0 and 5 liters. Receiver-operating characteristics analysis revealed that the sensitivity of BVM was moderate in median FO ranges between 1 and 3 liters (AUC 0.60-0.65), slightly higher for volume depletion of FO 3 liters (AUC 0.85). Conclusion: Devices that monitor blood volume are well suited to detect high FO, but are not as sensitive at moderate or low levels of fluid status.Keywords
This publication has 21 references indexed in Scilit:
- Dry-WeightClinical Journal of the American Society of Nephrology, 2010
- Hospital Treatment for Fluid Overload in the Medicare Hemodialysis PopulationClinical Journal of the American Society of Nephrology, 2010
- Relative Plasma Volume Monitoring During Hemodialysis Aids the Assessment of Dry WeightHypertension, 2010
- Guided optimization of fluid status in haemodialysis patientsNephrology Dialysis Transplantation, 2009
- Opinion: Can Chronic Volume Overload Be Recognized and Prevented in Hemodialysis Patients?Seminars in Dialysis, 2009
- The mortality risk of overhydration in haemodialysis patientsNephrology Dialysis Transplantation, 2009
- Importance of Whole-Body Bioimpedance Spectroscopy for the Management of Fluid BalanceBlood Purification, 2009
- Fluid balance, dry weight, and blood pressure in dialysisHemodialysis International, 2007
- Effect of High and Low Ultrafiltration Volume during Hemodialysis on Relative Blood VolumeASAIO Journal, 2006
- Assessment of Fluid Shifts of Body Compartments using Both Bioimpedance Analysis and Blood Volume MonitoringJournal of Korean Medical Science, 2006