The Local Lymph Node Assay (LLNA)
Authors:
Open Access
- 1 February 2012
- journal article
- research article
- Published by Wiley in Current Protocols in Toxicology
- Vol. 51 (1) , 20.7.1-20.7.14
Abstract
The murine local lymph node assay (LLNA) is a widely accepted method for assessing the skin sensitization potential of chemicals. Compared with other in vivo methods in guinea pig, the LLNA offers important advantages with respect to animal welfare, including a requirement for reduced animal numbers as well as reduced pain and trauma. In addition to hazard identification, the LLNA is used for determining the relative skin sensitizing potency of contact allergens as a pivotal contribution to the risk assessment process. The LLNA is the only in vivo method that has been subjected to a formal validation process. The original LLNA protocol is based on measurement of the proliferative activity of draining lymph node cells (LNC), as determined by incorporation of radiolabeled thymidine. Several variants to the original LLNA have been developed to eliminate the use of radioactive materials. One such alternative is considered here: the LLNA:BrdU‐ELISA method, which uses 5‐bromo‐2‐deoxyuridine (BrdU) in place of radiolabeled thymidine to measure LNC proliferation in draining nodes. Curr. Protoc. Toxicol. 51:20.7.1‐20.7.14. © 2012 by John Wiley & Sons, Inc.Keywords
This publication has 10 references indexed in Scilit:
- Skin irritation, false positives and the local lymph node assay: A guideline issue?Regulatory Toxicology and Pharmacology, 2011
- Local Lymph Node Assay: how testing laboratories apply OECD TG 429 for REACH purposesALTEX, 2011
- Potency values from the local lymph node assay: Application to classification, labelling and risk assessmentRegulatory Toxicology and Pharmacology, 2010
- The impact of vehicle on the relative potency of skin-sensitizing chemicals in the local lymph node assayCutaneous and Ocular Toxicology, 2008
- Evaluation of the skin sensitizing potency of chemicals by using the existing methods and considerations of relevance for elicitationContact Dermatitis, 2005
- Utility of historical vehicle‐control data in the interpretation of the local lymph node assayContact Dermatitis, 2003
- Examination of a vehicle for use with water soluble materials in the murine local lymph node assayFood and Chemical Toxicology, 2002
- The suitability of hexyl cinnamic aldehyde as a calibrant for the murine local lymph node assayContact Dermatitis, 2001
- Temporal stability of local lymph node assay responses to hexyl cinnamic aldehydeJournal of Applied Toxicology, 1998
- Results with OECD recommended positive control sensitizers in the maximization, Buehler and local lymph node assaysFood and Chemical Toxicology, 1993