Abstract
Phase‐shifted full‐bridge (PSFB) converters are widely used in medium‐ and high‐power applications due to their zero‐voltage‐switching (ZVS) capability. Conventional fixed dead‐time designs ensure ZVS under light‐load conditions but cause excessive dead time and increased body‐diode conduction losses at medium and heavy loads. This paper proposes a load‐current‐based closed‐loop dead‐time regulation method for PSFB converters, in which the dead time is dynamically adjusted in real time according to the measured output current. By correlating the required dead time with the resonant current level, the proposed approach forms a discrete‐time feedback regulation loop that updates the dead time on a cycle‐by‐cycle basis, ensuring sufficient ZVS margin while minimising unnecessary diode conduction. The control strategy is implemented using a digital signal processor without additional ZVS detection circuits, resulting in a hardware‐efficient solution with low implementation complexity. A 1 kW PSFB converter prototype is built to validate the proposed method. Experimental results demonstrate a significant reduction in excess dead time and body‐diode conduction losses, achieving an efficiency improvement of up to 0.2% compared with conventional fixed dead‐time control over a wide load range.