Abstract
In this paper an automatic identification method of system parameters is presented. The procedure is intended to be helpful in obtaining the parameters of more complicated systems than a state-of-the-art drive application consisting of an inverter connected directly to the AC machine. The laboratory setup and the analysis in the presented work deal with the system containing the common 3 phase inverter connected with either Permanent Magnet Synchronous Machine or Induction Motor through the LC-filter. This filter changes the order and the complexity of the system and due to that fact the standard identification procedures programmed in the industrial inverters can not be utilized.

This publication has 6 references indexed in Scilit: