Mario Pacas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mario Pacas has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Piotr Szczupak
University of Siegen, Hoelderlinstrasse 3, 57076 Siegen, GERMANY
3 shared publications - Adel Shaltout
Faculty of Engineering, University of Cairo, Giza, Egypt
2 shared publications - Amr A. Saleh
Electrical Engineering Department, Faculty of Engineering, Fayoum University, Fayoum 63514, Egypt
2 shared publications - Roberto Morales-Caporal
Instituto Tecnológico de Apizaco
2 shared publications - Sebastian Villwock
University of Siegen, Institute of Power Electronics and Electrical Drives, Hölderlinstrasse 3, 57068 Siegen, Germany
2 shared publications - C.M. Bhatia
Electrical Engg. Deptt., Indian Institute of Technology, Delhi. India
1 shared publication
Latest Publications
- 22 September 2023
- Published by Springer Nature in Electrical Engineering
- Vol. 106 (1) , 815-824
Low switching frequency predictive current control with dynamic model compensation for a 3-L inverter fed AC machine
- 22 September 2023
- Published by Springer Nature in Electrical Engineering
- Vol. 106 (1) , 815-824
Low switching frequency predictive current control with dynamic model compensation for a 3-L inverter fed AC machine
- 1 September 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 29-35
Rolling Bearing Condition Monitoring Based on Frequency Response Analysis
This paper deals with a new diagnosis method for detecting bearing faults. The diagnosis is carried out based on frequency response analysis. The detection of bearing damages on motor and load side of a mechanical drive system is addressed. The mechanics are assumed to be a two-inertia-system with one dominant resonant frequency. The frequency response of the mechanical system of the drive is obtained by using two measured signals. This method is regarded to be superior to one channel analysis that can be found in many technical papers in this field of research. The measurement of the required signal can be accomplished during operation of the plant in closed loop speed control. The system is excited by pseudo random binary testsignals. The deviations between the frequency response obtained during the commissioning of the plant and the curve measured under fault condition serve as indicators for the damage. The present paper addresses the detection of outer and inner race bearing faults. The majority of technical papers often are dedicated to experimental research regarding outer race faults. As inner race faults are much more difficult to diagnose, they are quite seldom in the scope of investigations. Both types of faults cause characteristic fault frequencies, which influence the frequency response of the mechanics. This paper contains experimental results which point out the reliability of the proposed analysis concept for rolling bearing condition monitoring.
- 1 September 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 29-35
Rolling Bearing Condition Monitoring Based on Frequency Response Analysis
This paper deals with a new diagnosis method for detecting bearing faults. The diagnosis is carried out based on frequency response analysis. The detection of bearing damages on motor and load side of a mechanical drive system is addressed. The mechanics are assumed to be a two-inertia-system with one dominant resonant frequency. The frequency response of the mechanical system of the drive is obtained by using two measured signals. This method is regarded to be superior to one channel analysis that can be found in many technical papers in this field of research. The measurement of the required signal can be accomplished during operation of the plant in closed loop speed control. The system is excited by pseudo random binary testsignals. The deviations between the frequency response obtained during the commissioning of the plant and the curve measured under fault condition serve as indicators for the damage. The present paper addresses the detection of outer and inner race bearing faults. The majority of technical papers often are dedicated to experimental research regarding outer race faults. As inner race faults are much more difficult to diagnose, they are quite seldom in the scope of investigations. Both types of faults cause characteristic fault frequencies, which influence the frequency response of the mechanics. This paper contains experimental results which point out the reliability of the proposed analysis concept for rolling bearing condition monitoring.
- 1 September 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 208-214
Automatic Parametric Model Identification Method for AC-Drives with LC-Filter
In this paper an automatic identification method of system parameters is presented. The procedure is intended to be helpful in obtaining the parameters of more complicated systems than a state-of-the-art drive application consisting of an inverter connected directly to the AC machine. The laboratory setup and the analysis in the presented work deal with the system containing the common 3 phase inverter connected with either Permanent Magnet Synchronous Machine or Induction Motor through the LC-filter. This filter changes the order and the complexity of the system and due to that fact the standard identification procedures programmed in the industrial inverters can not be utilized.
- 1 September 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 208-214
Automatic Parametric Model Identification Method for AC-Drives with LC-Filter
In this paper an automatic identification method of system parameters is presented. The procedure is intended to be helpful in obtaining the parameters of more complicated systems than a state-of-the-art drive application consisting of an inverter connected directly to the AC machine. The laboratory setup and the analysis in the presented work deal with the system containing the common 3 phase inverter connected with either Permanent Magnet Synchronous Machine or Induction Motor through the LC-filter. This filter changes the order and the complexity of the system and due to that fact the standard identification procedures programmed in the industrial inverters can not be utilized.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2220-2225
Predictive Direct Torque Control for Synchronous Reluctance Machines at Very Low and Zero Speed without Mechanical Sensor of the Rotor Position
This paper presents a technique to estimate the rotor position on predictive direct torque controlled synchronous reluctance machines at very low and zero speed without position sensor. In this range of operation, the natural anisotropy of the rotor is exploited and a test voltage signal is injected in certain control cycles and during short time. The additional test voltage does not produce any undesired torque as a compensation signal is provided. The identification of the rotor position is based on the measurement of the phase currents and their time derivatives. Due to the anisotropy of the rotor the inductances depend on the rotor position, so the time derivatives of the currents contain the required rotor position information. The obtained signals are processed by means of a quadrature phase-locked loop observer to extract the rotor position signal without detriments in phase and frequency. The developed identification scheme does need any encoder or additional special current or voltage sensors. Based on the mentioned strategy a sensorless predictive direct torque control scheme for the synchronous reluctance machine has been developed and implemented. Experimental results using a DSP and a field-programmable gate array embedded in the same board verify the effectiveness of the proposed sensorless predictive direct torque control scheme.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2220-2225
Predictive Direct Torque Control for Synchronous Reluctance Machines at Very Low and Zero Speed without Mechanical Sensor of the Rotor Position
This paper presents a technique to estimate the rotor position on predictive direct torque controlled synchronous reluctance machines at very low and zero speed without position sensor. In this range of operation, the natural anisotropy of the rotor is exploited and a test voltage signal is injected in certain control cycles and during short time. The additional test voltage does not produce any undesired torque as a compensation signal is provided. The identification of the rotor position is based on the measurement of the phase currents and their time derivatives. Due to the anisotropy of the rotor the inductances depend on the rotor position, so the time derivatives of the currents contain the required rotor position information. The obtained signals are processed by means of a quadrature phase-locked loop observer to extract the rotor position signal without detriments in phase and frequency. The developed identification scheme does need any encoder or additional special current or voltage sensors. Based on the mentioned strategy a sensorless predictive direct torque control scheme for the synchronous reluctance machine has been developed and implemented. Experimental results using a DSP and a field-programmable gate array embedded in the same board verify the effectiveness of the proposed sensorless predictive direct torque control scheme.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1340-1345
Fault Tolerant Field Oriented Control of Induction Motor for Loss of One Inverter Phase with Re-starting Capability
This paper describes a novel strategy for restarting the three phase induction motor in a voltage fed field oriented drive operating in the single phase mode after the loss of one of the inverter phases. The proposed method makes use of the readily presented switches for isolating the machine phase corresponding to the faulty inverter leg in the fault tolerant induction motor drive. With the aid of the two healthy inverter phases, three phases of the machine and sequential switching of two switches, block currents are fed into the machine to produce net average positive torque capable of restarting the machine. After the machine reaches a suitable speed the control structure is changed to the single phase field orientated mode of operation. The strategy is verified by computer simulation on a 10 kW induction machine.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1340-1345
Fault Tolerant Field Oriented Control of Induction Motor for Loss of One Inverter Phase with Re-starting Capability
This paper describes a novel strategy for restarting the three phase induction motor in a voltage fed field oriented drive operating in the single phase mode after the loss of one of the inverter phases. The proposed method makes use of the readily presented switches for isolating the machine phase corresponding to the faulty inverter leg in the fault tolerant induction motor drive. With the aid of the two healthy inverter phases, three phases of the machine and sequential switching of two switches, block currents are fed into the machine to produce net average positive torque capable of restarting the machine. After the machine reaches a suitable speed the control structure is changed to the single phase field orientated mode of operation. The strategy is verified by computer simulation on a 10 kW induction machine.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 59-64
Predictive Direct Torque Control for a Synchronous Reluctance Machine with Predetermined Stator Flux Compensation Down to Zero Speed
This paper presents enhancements of a predictive direct torque control for synchronous reluctance machines down to zero speed. The proposed control scheme is used when high- performance torque control is desired with the advantages of constant switching frequency and relative long sampling time. To get that, the control algorithm calculates one step in advance the switching instants of two possible active voltage space phasors that build the demanding torque. Next, the trajectory of the stator flux is predicted with these two pre-selected voltage space phasors and the optimum of them, which leads to the best trajectory of the stator flux at the end of the cycle, will be applied to the machine. At very low speeds a second active voltage space phasor is used to counteract the drop of the stator flux. In this paper it is shown, how the switching instant of this second voltage space phasor can be successfully predetermined before the switching instants of the other two voltage space phasors for torque and flux control as well as the criteria for its appropriate selection. The proposed algorithm has been implemented by using a digital signal processor (DSP) and a field programmable gate array (FPGA) embedded in the same board. Experimental results at very low and zero speed using a commercially available machine verify the effectiveness of the enhanced control scheme.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 59-64
Predictive Direct Torque Control for a Synchronous Reluctance Machine with Predetermined Stator Flux Compensation Down to Zero Speed
This paper presents enhancements of a predictive direct torque control for synchronous reluctance machines down to zero speed. The proposed control scheme is used when high- performance torque control is desired with the advantages of constant switching frequency and relative long sampling time. To get that, the control algorithm calculates one step in advance the switching instants of two possible active voltage space phasors that build the demanding torque. Next, the trajectory of the stator flux is predicted with these two pre-selected voltage space phasors and the optimum of them, which leads to the best trajectory of the stator flux at the end of the cycle, will be applied to the machine. At very low speeds a second active voltage space phasor is used to counteract the drop of the stator flux. In this paper it is shown, how the switching instant of this second voltage space phasor can be successfully predetermined before the switching instants of the other two voltage space phasors for torque and flux control as well as the criteria for its appropriate selection. The proposed algorithm has been implemented by using a digital signal processor (DSP) and a field programmable gate array (FPGA) embedded in the same board. Experimental results at very low and zero speed using a commercially available machine verify the effectiveness of the enhanced control scheme.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1950-1954
Identification of AC-Machines with LC-Filters by utilising Non-Parametric Models
The following paper presents an identification method of a field oriented controlled drive. Two different configurations are examined one with a permanent magnet synchronous machine and one with an induction machine both equipped with a sinus-filter (LC-filter) between the inverter and the machine. This identification algorithm can be seen as a first step of the complete identification method of the parameters of the mentioned systems. The algorithm is based on the Welch's method, usually used in the signal processing applications. In this paper only the method for the obtaining the admittance of machine and filter is addressed.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1950-1954
Identification of AC-Machines with LC-Filters by utilising Non-Parametric Models
The following paper presents an identification method of a field oriented controlled drive. Two different configurations are examined one with a permanent magnet synchronous machine and one with an induction machine both equipped with a sinus-filter (LC-filter) between the inverter and the machine. This identification algorithm can be seen as a first step of the complete identification method of the parameters of the mentioned systems. The algorithm is based on the Welch's method, usually used in the signal processing applications. In this paper only the method for the obtaining the admittance of machine and filter is addressed.
- 1 November 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics
- No. 1553572X,p. 817-822
Fault Tolerant Field Oriented Control of the Induction Motor for Loss of One Inverter Phase
This paper presents a fault tolerant strategy for the problem of loss of one phase in a field oriented controlled three phase induction motor. The proposed solution, rather than previously suggested solutions, is a control strategy in the single phase mode of operation of the induction motor. The suggested strategy can be applied to both delta and star connected motors. Average torque equivalent to the required reference torque is obtained. Tests are applied experimentally on a 10 kW motor to validate the proposed strategy. Limitation due to maximum permissible current is also discussed
- 1 November 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics
- No. 1553572X,p. 817-822
Fault Tolerant Field Oriented Control of the Induction Motor for Loss of One Inverter Phase
This paper presents a fault tolerant strategy for the problem of loss of one phase in a field oriented controlled three phase induction motor. The proposed solution, rather than previously suggested solutions, is a control strategy in the single phase mode of operation of the induction motor. The suggested strategy can be applied to both delta and star connected motors. Average torque equivalent to the required reference torque is obtained. Tests are applied experimentally on a 10 kW motor to validate the proposed strategy. Limitation due to maximum permissible current is also discussed
- 1 November 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics
- No. 1553572X,p. 1143-1148
Automatic Identification of a PMSM Drive Equipped with an Output LC-Filter
The following paper presents a fully automatic method of the identification of a field oriented controlled drive. The examined system consists of a permanent magnet synchronous machine PMSM, a sinus-filter (LC-filter) and an inverter. The advantage of the utilization of the filter in such systems lies in the decrease of the current and torque ripple, besides it features lower EMI production. The voltage stress on the windings of the machine is also lower. Despite the increased order of the system, the necessary number of sensors is not higher than in an application without filter. The identification of the system allows the utilization of the presented method in a wide range of industrial applications
- 1 November 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics
- No. 1553572X,p. 1143-1148
Automatic Identification of a PMSM Drive Equipped with an Output LC-Filter
The following paper presents a fully automatic method of the identification of a field oriented controlled drive. The examined system consists of a permanent magnet synchronous machine PMSM, a sinus-filter (LC-filter) and an inverter. The advantage of the utilization of the filter in such systems lies in the decrease of the current and torque ripple, besides it features lower EMI production. The voltage stress on the windings of the machine is also lower. Despite the increased order of the system, the necessary number of sensors is not higher than in an application without filter. The identification of the system allows the utilization of the presented method in a wide range of industrial applications
- 1 July 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4 (21635137) , 3056-3061
Deterministic Method for the Identification of Backlash in the Time Domain
This paper deals with the identification of mechanical backlash in drives. The development of a reliably working identification method as a contribution to automatic commissioning of electrical drives is intended. The main idea for identifying backlash is explained. Measurement results clearly point out the efficiency and flexibility of the identification strategy, which is proposed in this paper. Beyond the determination of the backlash the identification of the linear subsystem is addressed. The obtained identification results can be utilized for designing a controller and for the diagnostics of the actual state of the drive
- 1 July 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4 (21635137) , 3056-3061
Deterministic Method for the Identification of Backlash in the Time Domain
This paper deals with the identification of mechanical backlash in drives. The development of a reliably working identification method as a contribution to automatic commissioning of electrical drives is intended. The main idea for identifying backlash is explained. Measurement results clearly point out the efficiency and flexibility of the identification strategy, which is proposed in this paper. Beyond the determination of the backlash the identification of the linear subsystem is addressed. The obtained identification results can be utilized for designing a controller and for the diagnostics of the actual state of the drive