MRI screening for silicone breast implant rupture: accuracy, inter- and intraobserver variability using explantation results as reference standard
Authors:
- 6 March 2014
- journal article
- clinical trial
- Published by Springer Nature in European Radiology
- Vol. 24 (6) , 1167-1175
Abstract
The recall of Poly Implant Prothèse (PIP) silicone breast implants in 2010 resulted in large numbers of asymptomatic women with implants who underwent magnetic resonance imaging (MRI) screening. This study’s aim was to assess the accuracy and interobserver variability of MRI screening in the detection of rupture and extracapsular silicone leakage. A prospective study included 107 women with 214 PIP implants who underwent explantation preceded by MRI. In 2013, two radiologists blinded for previous MRI findings or outcome at surgery, independently re-evaluated all MRI examinations. A structured protocol described the MRI findings. The ex vivo findings served as reference standard. In 208 of the 214 explanted prostheses, radiologists agreed independently about the condition of the implants. In five of the six cases they disagreed (2.6 %), but subsequently reached consensus. A sensitivity of 93 %, specificity of 93 %, positive predictive value of 77 % and negative predictive value of 98 % was found. The interobserver agreement was excellent (kappa value of 0.92). MRI has a high accuracy in diagnosing rupture in silicone breast implants. Considering the high kappa value of interobserver agreement, MRI appears to be a consistent diagnostic test. A simple, uniform classification, may improve communication between radiologist and plastic surgeon. • MRI has a high accuracy in diagnosing rupture in silicone breast implants. • MRI appears to be a consistent diagnostic test with excellent interobserver agreement. • A simple, uniform classification system, improves communication between radiologist and plastic surgeon. • The interobserver agreement on implant rupture is higher than on extracapsular leakage.Keywords
This publication has 32 references indexed in Scilit:
- Assessing Strength of Evidence in Diagnostic TestsPlastic and Reconstructive Surgery, 2012
- The Effect of Study Design Biases on the Diagnostic Accuracy of Magnetic Resonance Imaging for Detecting Silicone Breast Implant Ruptures: A Meta-AnalysisPlastic and Reconstructive Surgery, 2011
- Silicone Breast Implants and Magnetic Resonance Imaging Screening for Rupture: Do U.S. Food and Drug Administration Recommendations Reflect an Evidence-Based Practice Approach to Patient Care?Plastic and Reconstructive Surgery, 2008
- The Diagnosis of Silicone Breast-Implant RuptureAnnals of Plastic Surgery, 2005
- The diagnosis of breast implant rupture: MRI findings compared with findings at explantationEuropean Journal of Radiology, 2005
- Imaging Signs and Radiologists' Jargon of Ruptured Breast ImplantsPlastic and Reconstructive Surgery, 1998
- Complications Leading to Surgery after Breast ImplantationNew England Journal of Medicine, 1997
- Breast imaging reporting and data system standardized mammography lexicon: observer variability in lesion description.American Journal of Roentgenology, 1996
- MR imaging of silicone breast implants: Evaluation of prospective and retrospective interpretations and interobserver agreementJournal of Magnetic Resonance Imaging, 1996
- Definitive Diagnosis of Breast Implant Rupture Using Magnetic Resonance ImagingPlastic and Reconstructive Surgery, 1993