Objective : The latest version of the Leksell Gamma Knife IconTM allows for mask- and frame-based fixation. Although mask fixation provides fractionated treatment and immobilization using a noninvasive method, it is not free from collision. The authors investigated the collision problem with a modified mask fixation method.Methods : This study presents a case of two meningiomas in the frontal area, where a collision occurs in the occipital area. A modified mask fixation method was introduced to avoid the collision : first, the edges of the head cushion were cut off and polystyrene beads with a diameter of approximately 5 cm were removed. Next, the head cushion was sealed using a stapler. Finally, the head cushion was flattened in the adapter. We compared the shot coordinates, 3-dimensional (3D) error, clearance distance, and vertical depth of the head cushion between the initial and modified mask fixations.Results : When comparing the initial and modified mask fixations, the difference in the shot coordinates was +10.5 mm along the y-axis, the difference in the 3D error was approximately 18 mm, and the difference in clearance was -10.2 mm. The head cushion was approximately 8 mm deeper in the modified mask fixation.Conclusion : Based on these findings, we recommend a modified mask fixation method for gamma knife radiosurgery using ICON with a collision.Keywords
Funding Information
- Chungbuk National University
This publication has 16 references indexed in Scilit:
- Frameless Stereotactic Radiosurgery on the Gamma Knife Icon: Early Experience From 100 PatientsNeurosurgery, 2019
- Frame versus Frameless Leksell Stereotactic Radiosurgery2019
- Assessment of motion error for frame-based and noninvasive mask-based fixation using the Leksell Gamma Knife Icon radiosurgery systemJournal of Neurosurgery, 2018
- Assessment of the accuracy and stability of frameless gamma knife radiosurgeryJournal of Applied Clinical Medical Physics, 2018
- Commissioning of the Leksell Gamma Knife® Icon™Medical Physics, 2017
- Evaluation of the stability of the stereotactic Leksell Frame G in Gamma Knife radiosurgeryJournal of Applied Clinical Medical Physics, 2016
- Effective usage of a clearance check to avoid a collision in Gamma Knife Perfexion radiosurgery with the Leksell skull frameJournal of Radiation Research, 2014
- Reliability of Stereotactic Coordinates of 1.5-Tesla and 3-Tesla MRI in Radiosurgery and Functional NeurosurgeryJournal of Korean Neurosurgical Society, 2014
- Frame stability and anatomical QA in radiosurgeryActa Neurochirurgica, 2011
- A noninvasive thermoplastic head immobilization systemJournal of Neurosurgery, 1995