Hyeong Cheol Moon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hyeong Cheol Moon has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Young Seok Park
Department of Neuroscience, College of Medicine, Chungbuk National University, Cheongju, Korea
12 shared publications Youn Joo Lee
Department of Radiology, Daejeon St. Mary's Hospital, The Catholic University of Korea, Daejeon, South Korea
4 shared publications- Yun-Sik Dho
National Cancer Center 5 Neuro-oncology clinic Goyang, Republic of Korea
3 shared publications Byeong Ho Oh
Department of Neurosurgery, GKS Center, Chungbuk National University Hospital, Cheongju, Republic of Korea
2 shared publications- Byung Jun Min
Department of Radiation Oncology, Chungbuk National University Hospital, Cheongju, Korea
2 shared publications Chan-A Park
Bioimaging Research Team, Korea Basic Science Institute, Cheongju, South Korea
2 shared publications
Latest Publications
- Open Access
- 27 April 2026
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 69 (5) , 815-821
Interpretation Challenges of Intraoperative Neurophysiological Monitoring Waveforms: A Technical Note
Intraoperative neurophysiological monitoring (IONM) using motor evoked potentials (MEPs) and somatosensory evoked potentials (SEPs) is widely used during neurosurgical procedures to reduce the risk of postoperative neurological deficits. However, interpretation of intraoperative waveforms is often challenging because signal changes do not always clearly meet established alarm criteria. In this technical note, we present representative patterns of normal, uncertain, and abnormal IONM waveforms and discuss interpretative challenges associated with ambiguous recordings. A retrospective descriptive review was performed on seven adult patients who underwent neurosurgical procedures with intraoperative MEP and SEP monitoring. Waveforms were qualitatively categorized based on morphology, amplitude, latency, and reproducibility across repeated stimulations. Normal waveforms demonstrated stable morphology, reproducible amplitudes, and physiologic latency ranges. Abnormal waveforms showed marked signal attenuation or complete loss of reproducible responses. In contrast, uncertain waveforms exhibited partial amplitude reduction, fluctuating morphology, limited reproducibility, or latency values overlapping normal ranges despite qualitative instability. These equivocal patterns could not be reliably classified using conventional binary alarm criteria alone. Our observations suggest that intraoperative MEP and SEP interpretation cannot always be reduced to a binary normal-versus-abnormal framework. Recognition of an intermediate “uncertain” waveform category may improve contextual intraoperative assessment, prompt careful reassessment of reversible factors, and better reflect the dynamic complexity of neuromonitoring.
- 27 April 2026
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 69 (5) , 815-821
Open AccessInterpretation Challenges of Intraoperative Neurophysiological Monitoring Waveforms: A Technical Note
Intraoperative neurophysiological monitoring (IONM) using motor evoked potentials (MEPs) and somatosensory evoked potentials (SEPs) is widely used during neurosurgical procedures to reduce the risk of postoperative neurological deficits. However, interpretation of intraoperative waveforms is often challenging because signal changes do not always clearly meet established alarm criteria. In this technical note, we present representative patterns of normal, uncertain, and abnormal IONM waveforms and discuss interpretative challenges associated with ambiguous recordings. A retrospective descriptive review was performed on seven adult patients who underwent neurosurgical procedures with intraoperative MEP and SEP monitoring. Waveforms were qualitatively categorized based on morphology, amplitude, latency, and reproducibility across repeated stimulations. Normal waveforms demonstrated stable morphology, reproducible amplitudes, and physiologic latency ranges. Abnormal waveforms showed marked signal attenuation or complete loss of reproducible responses. In contrast, uncertain waveforms exhibited partial amplitude reduction, fluctuating morphology, limited reproducibility, or latency values overlapping normal ranges despite qualitative instability. These equivocal patterns could not be reliably classified using conventional binary alarm criteria alone. Our observations suggest that intraoperative MEP and SEP interpretation cannot always be reduced to a binary normal-versus-abnormal framework. Recognition of an intermediate “uncertain” waveform category may improve contextual intraoperative assessment, prompt careful reassessment of reversible factors, and better reflect the dynamic complexity of neuromonitoring.
- Open Access
- 1 March 2026
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 69 (2) , 299-306
Recommendations for Quality Assurance Guidelines for Gamma Knife Radiosurgery in Republic of Korea : A Multi-institutional Survey
Objective : The Leksell Gamma Knife (LGK) is one of the most precise radiosurgical tools available. However, the quality assurance (QA) practices for LGK vary considerably across institutions in Korea. In this study, we aim to identify and standardize key QA items, categorized into daily, monthly, biannual, and annual protocols, based on a nationwide survey conducted at 16 medical centers. Additionally, the tolerance values for each QA items were reviewed, comparing them with the American Association of Physicists in Medicine Task Group (TG-178), and tailored to establish distinct Korean Gamma Knife radiosurgery (GKRS) tolerances reflecting local standards and regulatory requirements.Methods : The survey focused on QA practices for the LGK IconTM/EspritTM and PerfexionTM systems. The QA items were categorized into daily, monthly, biannual, and annual tasks in accordance with the guidelines set by TG-178. Sixteen participating institutions were asked to rate the importance of each QA item on a scale of 0 (not important) to 5 (extremely important). Items rated 4 or 5 were selected to create a national priority list.Results : Eleven daily, six monthly, and three annual QA items were identified as high priority. Daily QA tasks primarily focused on radiation and patient safety, whereas the monthly tasks were largely related to dosimetric validation. Annual QA emphasizes mechanical and dosimetric checks. Biannual evaluations were not prioritized as they were routinely performed by the manufacturer’s maintenance service (Elekta AB, Stockholm, Sweden).Conclusion : We succeeded in making recommendations for Gamma Knife QA standardization in Korea. Continuous QA updates are essential to ensure treatment safety, particularly with the introduction of new LGK models. These findings may contribute to the development of unified national QA guidelines for GKRS.
- 1 March 2026
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 69 (2) , 299-306
Open AccessRecommendations for Quality Assurance Guidelines for Gamma Knife Radiosurgery in Republic of Korea : A Multi-institutional Survey
Objective : The Leksell Gamma Knife (LGK) is one of the most precise radiosurgical tools available. However, the quality assurance (QA) practices for LGK vary considerably across institutions in Korea. In this study, we aim to identify and standardize key QA items, categorized into daily, monthly, biannual, and annual protocols, based on a nationwide survey conducted at 16 medical centers. Additionally, the tolerance values for each QA items were reviewed, comparing them with the American Association of Physicists in Medicine Task Group (TG-178), and tailored to establish distinct Korean Gamma Knife radiosurgery (GKRS) tolerances reflecting local standards and regulatory requirements.Methods : The survey focused on QA practices for the LGK IconTM/EspritTM and PerfexionTM systems. The QA items were categorized into daily, monthly, biannual, and annual tasks in accordance with the guidelines set by TG-178. Sixteen participating institutions were asked to rate the importance of each QA item on a scale of 0 (not important) to 5 (extremely important). Items rated 4 or 5 were selected to create a national priority list.Results : Eleven daily, six monthly, and three annual QA items were identified as high priority. Daily QA tasks primarily focused on radiation and patient safety, whereas the monthly tasks were largely related to dosimetric validation. Annual QA emphasizes mechanical and dosimetric checks. Biannual evaluations were not prioritized as they were routinely performed by the manufacturer’s maintenance service (Elekta AB, Stockholm, Sweden).Conclusion : We succeeded in making recommendations for Gamma Knife QA standardization in Korea. Continuous QA updates are essential to ensure treatment safety, particularly with the introduction of new LGK models. These findings may contribute to the development of unified national QA guidelines for GKRS.
- Open Access
- 1 September 2025
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 68 (5) , 616-621
Changes in Patient Marker Coordinates with High-Definition Motion Management System during Frameless Gamma Knife Radiosurgery
Objective : The Leksell Gamma Knife (LGK) Icon™ facilitates frameless (mask-based) fixation through its high-definition motion management (HDMM) system. However, the HDMM only records the intra-fractional motion values of patient marker without specifying changes along the X, Y, and Z axes. This study investigates the coordinate shifts in patient markers using the HDMM system during frameless gamma knife radiosurgery (GKRS) in patients with meningioma and metastases.Methods : We conducted a retrospective study of patients diagnosed with meningioma or metastases who underwent frameless GKRS using the LGK Icon™ between January and September 2023. All patients were immobilized using a Nanor thermoplastic mask (Orfit Industries, Wijnegem, Belgium) for frameless fixation. Sequential data of the patients’ nose marker coordinates (X, Y, Z) were imported into the LGK system, and subsequent coordinate changes were analyzed.Results : We evaluated patients with meningiomas (n=30) and metastases (n=30) who underwent GKRS with frameless fixation. None of the patients exhibited cognitive impairment or compliance issues. The median beam-on time was 44.2 minutes in patients with meningioma and 93.75 minutes in patients with metastases. In patients with meningioma, no significant intra-fractional displacements were found along the X (0.07±0.06 mm), Y (0.08±0.46 mm), and Z (0.08±0.04 mm) axes. However, in patients with metastases, the Y axis (0.57±0.37 mm, p<0.05) exhibited significantly greater intra-fractional displacements compared with the X axis (0.33±0.23 mm). No significant differences in intra-fractional displacement were observed between the X and Z (0.43±0.31 mm) axes or between the Y and Z axes. An analysis of movement over time revealed a significant increase in Y axis displacement after 30 minutes.Conclusion : Y axis movement, as indicated by the HDMM, was most prominent in patients with metastases. We recommend pressing the forehead when securing a mask to minimize nose marker movement. Additionally, when creating treatment plans for managing patients with metastases using the LGK Icon™, we suggest adding a 0.5 mm margin to the Y axis.
- 1 September 2025
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 68 (5) , 616-621
Open AccessChanges in Patient Marker Coordinates with High-Definition Motion Management System during Frameless Gamma Knife Radiosurgery
Objective : The Leksell Gamma Knife (LGK) Icon™ facilitates frameless (mask-based) fixation through its high-definition motion management (HDMM) system. However, the HDMM only records the intra-fractional motion values of patient marker without specifying changes along the X, Y, and Z axes. This study investigates the coordinate shifts in patient markers using the HDMM system during frameless gamma knife radiosurgery (GKRS) in patients with meningioma and metastases.Methods : We conducted a retrospective study of patients diagnosed with meningioma or metastases who underwent frameless GKRS using the LGK Icon™ between January and September 2023. All patients were immobilized using a Nanor thermoplastic mask (Orfit Industries, Wijnegem, Belgium) for frameless fixation. Sequential data of the patients’ nose marker coordinates (X, Y, Z) were imported into the LGK system, and subsequent coordinate changes were analyzed.Results : We evaluated patients with meningiomas (n=30) and metastases (n=30) who underwent GKRS with frameless fixation. None of the patients exhibited cognitive impairment or compliance issues. The median beam-on time was 44.2 minutes in patients with meningioma and 93.75 minutes in patients with metastases. In patients with meningioma, no significant intra-fractional displacements were found along the X (0.07±0.06 mm), Y (0.08±0.46 mm), and Z (0.08±0.04 mm) axes. However, in patients with metastases, the Y axis (0.57±0.37 mm, p<0.05) exhibited significantly greater intra-fractional displacements compared with the X axis (0.33±0.23 mm). No significant differences in intra-fractional displacement were observed between the X and Z (0.43±0.31 mm) axes or between the Y and Z axes. An analysis of movement over time revealed a significant increase in Y axis displacement after 30 minutes.Conclusion : Y axis movement, as indicated by the HDMM, was most prominent in patients with metastases. We recommend pressing the forehead when securing a mask to minimize nose marker movement. Additionally, when creating treatment plans for managing patients with metastases using the LGK Icon™, we suggest adding a 0.5 mm margin to the Y axis.
- Open Access
- 7 January 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (4)
Optimal mask fixation method for frameless radiosurgery with Leksell Gamma Knife IconTM
The Leksell Gamma Knife (LGK) IconTM is used for mask‐based and frame‐based fixation. The mask fixation provides a noninvasive method. However, an optimal mask fixation method is yet to be established. We evaluated the characteristics of three mask fixation methods (Plain, Folded, and Wide) for the LGK IconTM. Force‐sensitive resistor sensors were attached to the forehead, supraorbital, zygoma, mandible, and occipital bone of the phantom, and digital humidity and temperature sensors were attached to both temporal lobes. Cone‐beam computed tomography (CBCT) and high‐definition motion management (HDMM) for each mask fixation method were used to evaluate the phantom motion during the initial application. Subsequently, the mask was removed and reapplied on the second (1st reapplication) and third days (2nd reapplication). In the initial application, forces acting on most portions of the phantom were stabilized within 1.5 h. The largest force acted on the occipital bone for the Plain and Wide methods and on the mandible for the Folded method. The temperature rapidly approaches the initial temperature, whereas the humidity gradually approached the initial humidity in all fixation methods. The Folded method exhibited a significantly lower translation along the Y‐axis of the Leksell coordinate system, and rotations along all axes were under 0.5°. The HDMM values remained at 0.1 mm for all fixation methods. In the reapplications, the force acting on the occipital bone was significantly greater than that during the initial application for all mask fixation methods; the temperature and humidity remained unchanged. All mask fixation methods in the 1st reapplication were not significantly different from those in the 2nd reapplication. The Folded method is recommended as an optimal mask fixation for patients who require tight fixation; the Wide method can be considered if patient comfort is a priority.
- 7 January 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (4)
Open AccessOptimal mask fixation method for frameless radiosurgery with Leksell Gamma Knife IconTM
The Leksell Gamma Knife (LGK) IconTM is used for mask‐based and frame‐based fixation. The mask fixation provides a noninvasive method. However, an optimal mask fixation method is yet to be established. We evaluated the characteristics of three mask fixation methods (Plain, Folded, and Wide) for the LGK IconTM. Force‐sensitive resistor sensors were attached to the forehead, supraorbital, zygoma, mandible, and occipital bone of the phantom, and digital humidity and temperature sensors were attached to both temporal lobes. Cone‐beam computed tomography (CBCT) and high‐definition motion management (HDMM) for each mask fixation method were used to evaluate the phantom motion during the initial application. Subsequently, the mask was removed and reapplied on the second (1st reapplication) and third days (2nd reapplication). In the initial application, forces acting on most portions of the phantom were stabilized within 1.5 h. The largest force acted on the occipital bone for the Plain and Wide methods and on the mandible for the Folded method. The temperature rapidly approaches the initial temperature, whereas the humidity gradually approached the initial humidity in all fixation methods. The Folded method exhibited a significantly lower translation along the Y‐axis of the Leksell coordinate system, and rotations along all axes were under 0.5°. The HDMM values remained at 0.1 mm for all fixation methods. In the reapplications, the force acting on the occipital bone was significantly greater than that during the initial application for all mask fixation methods; the temperature and humidity remained unchanged. All mask fixation methods in the 1st reapplication were not significantly different from those in the 2nd reapplication. The Folded method is recommended as an optimal mask fixation for patients who require tight fixation; the Wide method can be considered if patient comfort is a priority.
- Open Access
- 28 November 2022
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 66 (4) , 476-481
Avoiding a Collision in Gamma Knife Radiosurgery : A Modified Mask Fixation Method
Objective : The latest version of the Leksell Gamma Knife IconTM allows for mask- and frame-based fixation. Although mask fixation provides fractionated treatment and immobilization using a noninvasive method, it is not free from collision. The authors investigated the collision problem with a modified mask fixation method.Methods : This study presents a case of two meningiomas in the frontal area, where a collision occurs in the occipital area. A modified mask fixation method was introduced to avoid the collision : first, the edges of the head cushion were cut off and polystyrene beads with a diameter of approximately 5 cm were removed. Next, the head cushion was sealed using a stapler. Finally, the head cushion was flattened in the adapter. We compared the shot coordinates, 3-dimensional (3D) error, clearance distance, and vertical depth of the head cushion between the initial and modified mask fixations.Results : When comparing the initial and modified mask fixations, the difference in the shot coordinates was +10.5 mm along the y-axis, the difference in the 3D error was approximately 18 mm, and the difference in clearance was -10.2 mm. The head cushion was approximately 8 mm deeper in the modified mask fixation.Conclusion : Based on these findings, we recommend a modified mask fixation method for gamma knife radiosurgery using ICON with a collision.
- 28 November 2022
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 66 (4) , 476-481
Open AccessAvoiding a Collision in Gamma Knife Radiosurgery : A Modified Mask Fixation Method
Objective : The latest version of the Leksell Gamma Knife IconTM allows for mask- and frame-based fixation. Although mask fixation provides fractionated treatment and immobilization using a noninvasive method, it is not free from collision. The authors investigated the collision problem with a modified mask fixation method.Methods : This study presents a case of two meningiomas in the frontal area, where a collision occurs in the occipital area. A modified mask fixation method was introduced to avoid the collision : first, the edges of the head cushion were cut off and polystyrene beads with a diameter of approximately 5 cm were removed. Next, the head cushion was sealed using a stapler. Finally, the head cushion was flattened in the adapter. We compared the shot coordinates, 3-dimensional (3D) error, clearance distance, and vertical depth of the head cushion between the initial and modified mask fixations.Results : When comparing the initial and modified mask fixations, the difference in the shot coordinates was +10.5 mm along the y-axis, the difference in the 3D error was approximately 18 mm, and the difference in clearance was -10.2 mm. The head cushion was approximately 8 mm deeper in the modified mask fixation.Conclusion : Based on these findings, we recommend a modified mask fixation method for gamma knife radiosurgery using ICON with a collision.
- Open Access
- 1 June 2021
- Published by Elsevier in Interdisciplinary Neurosurgery
- Vol. 24, 101057
The role of gamma knife radiosurgery in occurrence of secondary gliosarcoma after treatment of glioblastoma: A case report
- 1 June 2021
- Published by Elsevier in Interdisciplinary Neurosurgery
- Vol. 24, 101057
Open AccessThe role of gamma knife radiosurgery in occurrence of secondary gliosarcoma after treatment of glioblastoma: A case report
- Open Access
- 24 February 2021
- Published by SAGE Publications in Acta Radiologica Open
- Vol. 10 (2)
Prefrontal and hippocampal atrophy using 7-tesla magnetic resonance imaging in patients with Parkinson’s disease
Background: The pathology of Parkinson’s disease leads to morphological changes in brain structure. Currently, the progressive changes in gray matter volume that occur with time and are specific to patients with Parkinson’s disease, compared to healthy controls, remain unclear. High-tesla magnetic resonance imaging might be useful in differentiating neurological disorders by brain cortical changes. Purpose: We aimed to investigate patterns in gray matter changes in patients with Parkinson’s disease by using an automated segmentation method with 7-tesla magnetic resonance imaging. Material and Methods: High-resolution T1-weighted 7 tesla magnetic resonance imaging volumes of 24 hemispheres were acquired from 12 Parkinson’s disease patients and 12 age- and sex-matched healthy controls with median ages of 64.5 (range, 41–82) years and 60.5 (range, 25–74) years, respectively. Subgroup analysis was performed according to whether axial motor symptoms were present in the Parkinson’s disease patients. Cortical volume, cortical thickness, and subcortical volume were measured using a high-resolution image processing technique based on the Desikan-Killiany-Tourville atlas and an automated segmentation method (FreeSurfer version 6.0). Results: After cortical reconstruction, in 7 tesla magnetic resonance imaging volume segmental analysis, compared with the healthy controls, the Parkinson’s disease patients showed global cortical atrophy, mostly in the prefrontal area (rostral middle frontal, superior frontal, inferior parietal lobule, medial orbitofrontal, rostral anterior cingulate area), and subcortical volume atrophy in limbic/paralimbic areas (fusiform, hippocampus, amygdala). Conclusion: We first demonstrated that 7 tesla magnetic resonance imaging detects structural abnormalities in Parkinson’s disease patients compared to healthy controls using an automated segmentation method. Compared with the healthy controls, the Parkinson’s disease patients showed global prefrontal cortical atrophy and hippocampal area atrophy.
- 24 February 2021
- Published by SAGE Publications in Acta Radiologica Open
- Vol. 10 (2)
Open AccessPrefrontal and hippocampal atrophy using 7-tesla magnetic resonance imaging in patients with Parkinson’s disease
Background: The pathology of Parkinson’s disease leads to morphological changes in brain structure. Currently, the progressive changes in gray matter volume that occur with time and are specific to patients with Parkinson’s disease, compared to healthy controls, remain unclear. High-tesla magnetic resonance imaging might be useful in differentiating neurological disorders by brain cortical changes. Purpose: We aimed to investigate patterns in gray matter changes in patients with Parkinson’s disease by using an automated segmentation method with 7-tesla magnetic resonance imaging. Material and Methods: High-resolution T1-weighted 7 tesla magnetic resonance imaging volumes of 24 hemispheres were acquired from 12 Parkinson’s disease patients and 12 age- and sex-matched healthy controls with median ages of 64.5 (range, 41–82) years and 60.5 (range, 25–74) years, respectively. Subgroup analysis was performed according to whether axial motor symptoms were present in the Parkinson’s disease patients. Cortical volume, cortical thickness, and subcortical volume were measured using a high-resolution image processing technique based on the Desikan-Killiany-Tourville atlas and an automated segmentation method (FreeSurfer version 6.0). Results: After cortical reconstruction, in 7 tesla magnetic resonance imaging volume segmental analysis, compared with the healthy controls, the Parkinson’s disease patients showed global cortical atrophy, mostly in the prefrontal area (rostral middle frontal, superior frontal, inferior parietal lobule, medial orbitofrontal, rostral anterior cingulate area), and subcortical volume atrophy in limbic/paralimbic areas (fusiform, hippocampus, amygdala). Conclusion: We first demonstrated that 7 tesla magnetic resonance imaging detects structural abnormalities in Parkinson’s disease patients compared to healthy controls using an automated segmentation method. Compared with the healthy controls, the Parkinson’s disease patients showed global prefrontal cortical atrophy and hippocampal area atrophy.
- Open Access
- 1 September 2020
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 63 (5) , 579-589
An Optimization of AAV-82Q-Delivered Rat Model of Huntington’s Disease
No optimum genetic rat Huntington model both neuropathological using an adeno-associated virus (AAV-2) vector vector has been reported to date. We investigated whether direct infection of an AAV2 encoding a fragment of mutant huntingtin (AV2-82Q) into the rat striatum was useful for optimizing the Huntington rat model. We prepared ten unilateral models by injecting AAV2-82Q into the right striatum, as well as ten bilateral models. In each group, five rats were assigned to either the 2×1012 genome copies (GC)/mL of AAV2-82Q (×1, low dose) or 2×1013 GC/mL of AAV2-82Q (×10, high dose) injection model. Ten unilateral and ten bilateral models injected with AAV-empty were also prepared as control groups. We performed cylinder and stepping tests 2, 4, 6, and 8 weeks after injection, tested EM48 positive mutant huntingtin aggregates. The high dose of unilateral and bilateral AAV2-82Q model showed a greater decrease in performance on the stepping and cylinder tests. We also observed more prominent EM48-positive mutant huntingtin aggregates in the medium spiny neurons of the high dose of AAV2-82Q injected group. Based on the results from the present study, high dose of AAV2-82Q is the optimum titer for establishing a Huntington rat model. Delivery of high dose of human AAV2-82Q resulted in the manifestation of Huntington behaviors and optimum expression of the huntingtin protein in vivo.
- 1 September 2020
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 63 (5) , 579-589
Open AccessAn Optimization of AAV-82Q-Delivered Rat Model of Huntington’s Disease
No optimum genetic rat Huntington model both neuropathological using an adeno-associated virus (AAV-2) vector vector has been reported to date. We investigated whether direct infection of an AAV2 encoding a fragment of mutant huntingtin (AV2-82Q) into the rat striatum was useful for optimizing the Huntington rat model. We prepared ten unilateral models by injecting AAV2-82Q into the right striatum, as well as ten bilateral models. In each group, five rats were assigned to either the 2×1012 genome copies (GC)/mL of AAV2-82Q (×1, low dose) or 2×1013 GC/mL of AAV2-82Q (×10, high dose) injection model. Ten unilateral and ten bilateral models injected with AAV-empty were also prepared as control groups. We performed cylinder and stepping tests 2, 4, 6, and 8 weeks after injection, tested EM48 positive mutant huntingtin aggregates. The high dose of unilateral and bilateral AAV2-82Q model showed a greater decrease in performance on the stepping and cylinder tests. We also observed more prominent EM48-positive mutant huntingtin aggregates in the medium spiny neurons of the high dose of AAV2-82Q injected group. Based on the results from the present study, high dose of AAV2-82Q is the optimum titer for establishing a Huntington rat model. Delivery of high dose of human AAV2-82Q resulted in the manifestation of Huntington behaviors and optimum expression of the huntingtin protein in vivo.
- 18 August 2020
- Published by Springer Nature in Journal of Molecular Neuroscience
- Vol. 71 (3) , 638-650
The Effect of Optogenetic Inhibition of the Anterior Cingulate Cortex in Neuropathic Pain Following Sciatic Nerve Injury
Cortical disinhibition is the underlying pathological alteration contributing to neuropathic pain associated with peripheral nerve injury. Nerve injury resulting in disinhibition of the anterior cingulate cortex has been reported. However, the effect of optogenetic inhibition of the anterior cingulate cortex (ACC) on the sensory component of nerve injury–induced neuropathic pain has not been well studied. To investigate the feasibility of optogenetic ACC modulation, we injected an optogenetic virus or a null virus into the ACC of a nerve injury–induced neuropathic pain model. The unilateral ACC was modulated, and the optogenetic effect was measured by mechanical and thermal sensitivity tests. The assessment was performed in “pre—light off,” “stimulation—yellow light on,” and “post—light off” states. Optogenetic inhibition of the ACC in injury models revealed improved mechanical and thermal latencies with profound pain-relieving effects against nerve injury–induced neuropathic pain. The sensory thalamic discharge in electrophysiological in vivo recordings was also altered during laser stimulation. This finding indicates that hyperactivity of the ACC in nerve injury increases output to the spinothalamic tract through direct or indirect pathways. The direct photoinhibition of ACC neurons could play a vital role in restoring equilibrium and provide novel insight into techniques that can assuage peripheral nerve injury–induced neuropathic pain.
- 18 August 2020
- Published by Springer Nature in Journal of Molecular Neuroscience
- Vol. 71 (3) , 638-650
The Effect of Optogenetic Inhibition of the Anterior Cingulate Cortex in Neuropathic Pain Following Sciatic Nerve Injury
Cortical disinhibition is the underlying pathological alteration contributing to neuropathic pain associated with peripheral nerve injury. Nerve injury resulting in disinhibition of the anterior cingulate cortex has been reported. However, the effect of optogenetic inhibition of the anterior cingulate cortex (ACC) on the sensory component of nerve injury–induced neuropathic pain has not been well studied. To investigate the feasibility of optogenetic ACC modulation, we injected an optogenetic virus or a null virus into the ACC of a nerve injury–induced neuropathic pain model. The unilateral ACC was modulated, and the optogenetic effect was measured by mechanical and thermal sensitivity tests. The assessment was performed in “pre—light off,” “stimulation—yellow light on,” and “post—light off” states. Optogenetic inhibition of the ACC in injury models revealed improved mechanical and thermal latencies with profound pain-relieving effects against nerve injury–induced neuropathic pain. The sensory thalamic discharge in electrophysiological in vivo recordings was also altered during laser stimulation. This finding indicates that hyperactivity of the ACC in nerve injury increases output to the spinothalamic tract through direct or indirect pathways. The direct photoinhibition of ACC neurons could play a vital role in restoring equilibrium and provide novel insight into techniques that can assuage peripheral nerve injury–induced neuropathic pain.
- Open Access
- 3 August 2019
- Published by SAGE Publications in Acta Radiologica
- Vol. 61 (4) , 487-495
Precentral and cerebellar atrophic changes in moyamoya disease using 7-T magnetic resonance imaging
Background: Chronic repeated transient ischemic changes are one of the common symptoms of moyamoya disease that could affect cortical and subcortical atrophy. Purpose: We aimed to assess the cortical gray matter volume and thickness, white matter subcortical volume, and clinical characteristics using 7-T magnetic resonance imaging (MRI) and MR angiography (MRA). Material and Methods: In this case-control study, whole-brain parcellation of gray matter and subcortical volumes were manually assessed in nine patients with moyamoya disease (18 hemispheres; median age = 34 years; age range = 10–60 years) and nine healthy controls (18 hemispheres; median age = 29 years; age range = 20–62 years) matched for age and sex, who underwent both 7-T MRI and MRA. The volumes were measured using high-resolution image (<1 mm) processing based on the Desikan-Killiany-Tourville (DKT) atlas, via an automated segmentation method (FreeSurfer version 6.0). Results: The gray matter volume of the left precentral cortex and the white matter volume of the subcortical cerebellum were lower in both hemispheres in the patients with moyamoya disease compared to the healthy controls. Conclusion: Gray matter atrophy in the precentral cortex and cerebellar white matter were detected in this 7-T MRI volumetric analysis study of patients with moyamoya disease who experienced repeated transient ischemic changes. Cortical atrophy in precentral cortex and cerebellum could explain the transient motor weakness in patients with moyamoya disease, as one of the early findings was that patients with moyamoya disease do not have detectable infarction changes on conventional MRI images.
- 3 August 2019
- Published by SAGE Publications in Acta Radiologica
- Vol. 61 (4) , 487-495
Open AccessPrecentral and cerebellar atrophic changes in moyamoya disease using 7-T magnetic resonance imaging
Background: Chronic repeated transient ischemic changes are one of the common symptoms of moyamoya disease that could affect cortical and subcortical atrophy. Purpose: We aimed to assess the cortical gray matter volume and thickness, white matter subcortical volume, and clinical characteristics using 7-T magnetic resonance imaging (MRI) and MR angiography (MRA). Material and Methods: In this case-control study, whole-brain parcellation of gray matter and subcortical volumes were manually assessed in nine patients with moyamoya disease (18 hemispheres; median age = 34 years; age range = 10–60 years) and nine healthy controls (18 hemispheres; median age = 29 years; age range = 20–62 years) matched for age and sex, who underwent both 7-T MRI and MRA. The volumes were measured using high-resolution image (<1 mm) processing based on the Desikan-Killiany-Tourville (DKT) atlas, via an automated segmentation method (FreeSurfer version 6.0). Results: The gray matter volume of the left precentral cortex and the white matter volume of the subcortical cerebellum were lower in both hemispheres in the patients with moyamoya disease compared to the healthy controls. Conclusion: Gray matter atrophy in the precentral cortex and cerebellar white matter were detected in this 7-T MRI volumetric analysis study of patients with moyamoya disease who experienced repeated transient ischemic changes. Cortical atrophy in precentral cortex and cerebellum could explain the transient motor weakness in patients with moyamoya disease, as one of the early findings was that patients with moyamoya disease do not have detectable infarction changes on conventional MRI images.