PROTEIN SEPARATION BY CROSS-AXIS COIL PLANET CENTRIFUGE WITH SPIRAL COLUMN ASSEMBLIES
Authors:
- 1 September 2002
- journal article
- Published by Taylor & Francis in Journal of Liquid Chromatography & Related Technologies
- Vol. 25 (17) , 2665-2678
Abstract
A newly fabricated spiral column assembly was first applied to the countercurrent chromatographic separation of proteins using the cross-axis coil planet centrifuge (cross-axis CPC). The separation was performed by a set of stable proteins such as cytochrome C, myoglobin, and lysozyme with an aqueous–aqueous polymer phase solvent system composed of 12.5% (w/w) polyethylene glycol (PEG) 1000–12.5% (w/w) dibasic potassium phosphate. Three sets of left-handed single-layer spiral columns with different IDs (1.0, 1.5, and 2.0 mm) were employed to investigate the effect of column ID on partition efficiency at four different elution modes. The elution modes consisted of the combinations of the direction of revolution (PI=counterclock-wise; PII=clockwise), the head–tail elution mode (H=head to tail; T=tail to head), and the inward–outward elution mode (I=inward; O=outward). Among these experiments, the best separation of proteins was attained using a 1.5 mm-ID column assembly with the PI-H-O elution mo...Keywords
This publication has 12 references indexed in Scilit:
- PROTEIN SEPARATION BY CROSS-AXIS COIL PLANET CENTRIFUGE WITH TWO DIFFERENT POSITIONS OF ECCENTRIC COIL ASSEMBLIES USING POLYETHYLENE GLYCOL-DEXTRAN SOLVENT SYSTEMJournal of Liquid Chromatography & Related Technologies, 2000
- Effect of Elution Modes on Protein Separation by Cross-Axis Coil Planet Centrifuge with Two Different Types of Coiled ColumnsPreparative Biochemistry & Biotechnology, 1999
- Protein Separation by Cross-Axis Coil Planet Centrifuge with Two Different Types of Coiled ColumnsJournal of Liquid Chromatography & Related Technologies, 1998
- Protein Separation by Improved Cross-Axis Coil Planet Centrifuge with Eccentric Coil AssembliesJournal of Liquid Chromatography & Related Technologies, 1996
- Countercurrent chromatographic analysis of ovalbumin obtained from various sources using the cross-axis coil planet centrifugeJournal of Chromatography A, 1996
- Studies on a new cross-axis coil planet centrifuge for performing counter-current chromatography: II. Path and acceleration of coils and comparison with type J coil planet centrifugeJournal of Chromatography A, 1993
- Studies on a new cross-axis coil planet centrifuge for performing counter-current chromatographyJournal of Chromatography A, 1993
- Cross-Axis Synchronous Flow-Through Coil Planet Centrifuge Free of Rotary Seals for Preparative Countercurrent Chromatography. Part II. Studies on Phase Distribution and Partition Efficiency in Coaxial CoilsSeparation Science and Technology, 1987
- Cross-Axis Synchronous Flow-Through Coil Planet Centrifuge Free of Rotary Seals for Preparative Countercurrent Chromatography. Part I. Apparatus and Analysis of AccelerationSeparation Science and Technology, 1987
- Experimental observations of the hydrodynamic behavior of solvent systems in high-speed counter-current chromatographyJournal of Chromatography A, 1984