Effect of Elution Modes on Protein Separation by Cross-Axis Coil Planet Centrifuge with Two Different Types of Coiled Columns
Authors:
- Yozo KabasawaYKYozo Kabasawa
- Yoichiro ItoYIYoichiro Ito
- 1 January 1999
- journal article
- research article
- Published by Taylor & Francis in Preparative Biochemistry & Biotechnology
- Vol. 29 (2) , 139-150
Abstract
Effect of elution modes on protein separation was investigated using cross-axis coil planet centrifuge (cross-axis CPC) with two different types of coiled columns, i.e., eccentric coil and toroidal coil assemblies. Myoglobin and lysozyme were separated with an aqueous two-phase solvent system composed of 12·5% (w/w) polyethylene glycol 1000 and 12·5% (w/w) dibasic potassium phosphate. The substantial effect of elution modes was observed by the toroidal coil, while the negative result was given at the eccentric coil. Using the toroidal coil, higher peak resolution of proteins was attained at the tail to head elution mode. In the outward lower phase mobile elution mode, the satisfactory separation was obtained by both eccentric coil and toroidal coil assemblies. However, in the inward upper phase mobile elution mode, the toroidal coil produced a broad and asymmetric myoglobin peak. The analysis using polyacrylamide gel electrophoresis revealed that the toroidal coil partially separated the components originally present in the myoglobin sample. As the result, a modified equation was devised to express the peak resolution (Rs) using the lysozyme peak. The overall results indicated that the toroidal coil produced better partition efficiency than the eccentric coil under the optimized experimental condition including the direction of the Coriolis force acting on the mobile phase in the toroidal coil.Keywords
This publication has 13 references indexed in Scilit:
- Countercurrent Chromatographic Separation of Proteins by Cross-Axis Coil Planet Centrifuge: Choice of Polymer Phase Systems and Revolution SpeedJournal of Liquid Chromatography & Related Technologies, 1998
- Protein Separation by Cross-Axis Coil Planet Centrifuge with Two Different Types of Coiled ColumnsJournal of Liquid Chromatography & Related Technologies, 1998
- Effects of Coriolis Force on Countercurrent ChromatographyJournal of Liquid Chromatography & Related Technologies, 1998
- Protein Separation by Improved Cross-Axis Coil Planet Centrifuge with Eccentric Coil AssembliesJournal of Liquid Chromatography & Related Technologies, 1996
- Cross-Axis Coil Planet Centrifuge1995
- Studies on a new cross-axis coil planet centrifuge for performing counter-current chromatography: II. Path and acceleration of coils and comparison with type J coil planet centrifugeJournal of Chromatography A, 1993
- Studies on new cross-axis coil planet centrifuge for performing counter-current chromatographyJournal of Chromatography A, 1993
- Studies on a new cross-axis coil planet centrifuge for performing counter-current chromatographyJournal of Chromatography A, 1993
- Cross-Axis Synchronous Flow-Through Coil Planet Centrifuge Free of Rotary Seals for Preparative Countercurrent Chromatography. Part II. Studies on Phase Distribution and Partition Efficiency in Coaxial CoilsSeparation Science and Technology, 1987
- Cross-Axis Synchronous Flow-Through Coil Planet Centrifuge Free of Rotary Seals for Preparative Countercurrent Chromatography. Part I. Apparatus and Analysis of AccelerationSeparation Science and Technology, 1987