Comparative evaluation of diagnostic and analytical performance of DIRUI FUS-200 and MUS-3600 fully automated urine analyzers
Authors:
- 3 October 2025
- journal article
- Published by Taylor & Francis in Scandinavian Journal of Clinical and Laboratory Investigation
- Vol. 85 (7) , 571-580
Abstract
The aim was to assess and compare the analytical performance of the FUS-200 and its new upgrade, the MUS-3600 urine autoanalyzers, and to compare performance with manual microscopy. First morning, void urine samples were randomly collected, and suitable samples were analyzed on both autoanalyzers. In addition, concurrent manual microscopic examinations were performed for all suitable urine samples. Carry-over, linearity and imprecision analysis were performed to assess analytical and diagnostic performance of both urine autoanalyzers according to Clinical and Laboratory Standards Institute (CLSI) EP15-A2, and the study was conducted in accordance with CLSI GP16-A3 Urinalysis; Approved Guideline. A total of 518 samples were collected, and of these, 494 (95.4%) were suitable for analysis and were included in the study. Sensitivity and positive likelihood ratio (LR+) values for WBC and squamous epithelium (SqEC) counts for both autoanalyzers were >90% and >10%, respectively. Specificity and LR+ values obtained from MUS-3600 were better compared to the FUS-200 (respectively 92.8 vs. 84.7; 5.5 vs. 10.1). One group agreement between the MUS-3600 and manual microscopy was >90%. Both analyzers displayed comparable performance for RBC and WBC counts, which were moderately correlated with each other. These results show the diagnostic performance of the MUS-3600 and FUS-200 was satisfactory for urine sediment analysis and was compatible with manual microscopy findings. However, random urine samples are sub-optimal for evaluating diagnostic performance, particularly for bacterial, cast, crystal and yeast analysis. Thus, we recommend using more appropriate urine samples for this comparison, such as from patients with suspected urinary tract infections.Keywords
This publication has 19 references indexed in Scilit:
- Comparison of Labsan Tricell-1000 and Dirui FUS-2000 automated urine analyzers with manual microscopyPractical Laboratory Medicine, 2024
- Evaluation of the fully automated urine particle analyzer UF‐1500Journal of Clinical Laboratory Analysis, 2023
- Diagnostic performance of urine analysis based on flow microimaging and artificial intelligence recognition technology in suspected urinary tract infection patientsScandinavian Journal of Clinical and Laboratory Investigation, 2022
- A comparison of automated urine analyzers cobas 6500, UN 3000-111b and iRICELL 3000 with manual microscopic urinalysisPractical Laboratory Medicine, 2021
- Performance of automated urine analyzers using flow cytometric and digital image-based technology in routine urinalysisScandinavian Journal of Clinical and Laboratory Investigation, 2019
- Urine Sediment Examination in the Diagnosis and Management of Kidney Disease: Core Curriculum 2019American Journal of Kidney Diseases, 2019
- The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysisPractical Laboratory Medicine, 2016
- Comparison of Fully Automated Urine Sediment Analyzers H800‐FUS100 and Labumat‐Urised with Manual MicroscopyJournal of Clinical Laboratory Analysis, 2013
- Advances in the clinical laboratory assessment of urinary sedimentClinica Chimica Acta, 2004
- The role of automated urine particle flow cytometry in clinical practiceClinica Chimica Acta, 2000