Case Studies of Harmonic Distortion in Power Transformers Due to Geomagnetically Induced Current Flows
Authors:
- 21 May 2023
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Abstract
Geomagnetically induced currents (GICs) flow through grounding circuits into power systems, when triggered by geomagnetic disturbances. Power transformers (with grounding connections) are one of the common paths for GIC flows into power systems. The flow of GICs through a power transformer can create adverse impacts on its operation, including disruptions in the reactive power flow and significant harmonic distortions in primary and secondary side currents. This paper presents case studies for analyzing the harmonic distortion in primary and secondary side currents due to various levels of GIC flows in power transformers. Presented case studies are conducted on two laboratory power transformers with different core types, power ratings, voltage ratings, and winding configurations. Each of these power transformers is tested for various levels of GIC flows with its loading being varied from no-load to rated power. Results of conducted case studies conclude that the dc component, $2^{\mathrm{n}\mathrm{d}}$ harmonic, and $3^{\mathrm{r}\mathrm{d}}$ harmonic are dominant in primary and secondary sides currents at all levels of GIC flows. Other harmonic components ($5^{\mathrm{t}\mathrm{h}}, 6^{\mathrm{t}\mathrm{h}}$, and $7^{\mathrm{t}\mathrm{h}}$) can be observed with lower magnitudes than the dc component, $2^{\mathrm{n}\mathrm{d}}$ harmonic, and $3^{\mathrm{r}\mathrm{d}}$ harmonic.
Keywords
This publication has 15 references indexed in Scilit:
- Analysis of Three-Phase Transformer Response due to GIC Using an Advanced Duality-Based ModelIEEE Transactions on Power Delivery, 2015
- On the Design and Capacity of a Grounding Configuration for Grid-Connected DGUsIEEE Transactions on Industry Applications, 2015
- Impacts of Grounding Configurations on Responses of Ground Protective Relays for DFIG-Based WECSs—Part I: Solid Ground FaultsIEEE Transactions on Industry Applications, 2015
- Enhanced Transformer Model for Low- and Mid-Frequency Transients—Part I: Model DevelopmentIEEE Transactions on Power Delivery, 2014
- Enhanced Transformer Model for Low- and Mid-Frequency Transients—Part II: Validation and Simulation ResultsIEEE Transactions on Power Delivery, 2014
- Impacts of grounding configurations on responses of ground protective relays for DFIG-based WECSs2014
- A Test Case for the Calculation of Geomagnetically Induced CurrentsIEEE Transactions on Power Delivery, 2012
- Impacts of Hysteresis and Magnetic Couplings on the Stability Domain of Ferroresonance in Asymmetric Three-Phase Three-Leg TransformersIEEE Transactions on Energy Conversion, 2010
- A New Transient Model for Three-Phase Power Transformers Using a Wavelet Filter BankIEEE Transactions on Power Delivery, 2005