Correlating Optical Bench Performance With Clinical Defocus Curves in Varifocal and Trifocal Intraocular Lenses
Authors:
- Ana B. Plaza-PucheAPAna B. Plaza-Puche
- Jorge L. AlióJorge L. Alió
- Scott MacRaeSMScott MacRae
- Len ZheleznyakLZLen Zheleznyak
- Esperanza SalaESEsperanza Sala
- Geunyoung YoonGYGeunyoung Yoon
- 1 May 2015
- journal article
- research article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 31 (5) , 300-307
Abstract
PURPOSE: To investigate the correlations existing between a trifocal intraocular lens (IOL) and a varifocal IOL using the “ex vivo” optical bench through-focus image quality analysis and the clinical visual performance in real patients by study of the defocus curves. METHODS: This prospective, consecutive, nonrandomized, comparative study included a total of 64 eyes of 42 patients. Three groups of eyes were differentiated according to the IOL implanted: 22 eyes implanted with the varifocal Lentis Mplus LS-313 IOL (Oculentis GmbH, Berlin, Germany); 22 eyes implanted with the trifocal FineVision IOL (Physiol, Liege, Belgium), and 20 eyes implanted with the monofocal Acrysof SA60AT IOL (Alcon Laboratories, Inc., Fort Worth, TX). Visual outcomes and defocus curve were evaluated postoperatively. Optical bench through-focus performance was quantified by computing an image quality metric and the cross-correlation coefficient between an unaberrated reference image and captured retinal images from a model eye with a 3.0-mm artificial pupil. RESULTS: Statistically significant differences among defocus curves of different IOLs were detected for the levels of defocus from −4.00 to −1.00 diopters (D) ( P < .01). Significant correlations were found between the optical bench image quality metric results and logMAR visual acuity scale in all groups (Lentis Mplus group: r = −0.97, P < .01; FineVision group: r = −0.82, P < .01; Acrysof group: r = −0.99, P < .01). Linear predicting models were obtained. CONCLUSIONS: Significant correlations were found between logMAR visual acuity and image quality metric for the multifocal and monofocal IOLs analyzed. This finding enables surgeons to predict visual outcomes from the optical bench analysis. [ J Refract Surg. 2015;31(5):300–307.]Keywords
This publication has 35 references indexed in Scilit:
- Modified Monovision With Spherical Aberration to Improve Presbyopic Through-Focus Visual PerformanceInvestigative Ophthalmology & Visual Science, 2013
- Visual and refractive outcomes after implantation of a fully diffractive trifocal lensClinical Ophthalmology, 2012
- Rotationally Asymmetric Multifocal IOL Implantation With and Without Capsular Tension Ring: Refractive and Visual Outcomes and Intraocular Optical PerformanceJournal of Refractive Surgery, 2012
- Comparison of a New Refractive Multifocal Intraocular Lens with an Inferior Segmental Near Add and a Diffractive Multifocal Intraocular LensOphthalmology, 2012
- Visual function comparison of 2 aspheric multifocal intraocular lensesJournal of Cataract & Refractive Surgery, 2012
- Objective evaluation of through-focus optical performance of presbyopia-correcting intraocular lenses using an optical bench systemJournal of Cataract & Refractive Surgery, 2011
- Visual outcomes and optical performance of a monofocal intraocular lens and a new-generation multifocal intraocular lensJournal of Cataract & Refractive Surgery, 2011
- Expanding depth of focus by modifying higher-order aberrations induced by an adaptive optics visual simulatorJournal of Cataract & Refractive Surgery, 2009
- Evidence for Delayed Presbyopia after Photorefractive Keratectomy for MyopiaOphthalmology, 2006
- European Multicenter Study of the AcrySof ReSTOR Apodized Diffractive Intraocular LensOphthalmology, 2006