Comparison of Doppler ultrasonic and oscillometric devices (with or without proprietary optimisations) for non-invasive blood pressure measurement in conscious cats
Authors:
Open Access
- 25 June 2020
- journal article
- research article
- Published by SAGE Publications in Journal of Feline Medicine and Surgery
- Vol. 23 (2) , 121-130
Abstract
This study compared Doppler and oscillometric (PetMAP+) devices (with or without proprietary optimisations) for the non-invasive measurement of blood pressure in conscious cats. Twenty-three cats were enrolled; however, five were excluded as fewer than five measurements were obtained for each assessment. All measurements were obtained according to American College of Veterinary Internal Medicine consensus guidelines. Oscillometric device modes A and B were operated according to the manufacturer’s guidelines. Doppler and oscillometric devices were used alternately as the first device. Systolic arterial blood pressure (SAP) measurements were obtained by Doppler (SAPd) and oscillometry; the mean of each set of five values was used for statistical analysis. There was a significant difference between SAPd and SAP measurements in oscillometric modes A (P P P = 0.002) and B (P <0.001). Both modes’ MAP readings were lower than SAPd and oscillometric A MAP was closer to SAPd (–14.94 mmHg), with a smaller bias and narrower LOA. The findings support that Doppler and oscillometric devices cannot be used interchangeably, with or without proprietary optimisations. Methodology should always be taken into account and reference intervals (RIs) need to be defined for the different methodologies. Until methodology-specific RIs are published, definitive diagnosis of hypertension and sub-staging of patients with kidney disease according to the International Renal Interest Society guidelines remains challenging.Keywords
This publication has 49 references indexed in Scilit:
- Comparison of how well conscious cats tolerate blood pressure measurement from the radial and coccygeal arteriesJournal of Feline Medicine and Surgery, 2012
- Agreement between directly measured blood pressure and pressures obtained with three veterinary-specific oscillometric units in catsJournal of the American Veterinary Medical Association, 2010
- Response of cats to familiar and unfamiliar human contact using continuous direct arterial blood pressure measurementResearch in Veterinary Science, 2008
- Retrospective analysis of selected predictors of mortality within a veterinary intensive care unitJournal of Feline Medicine and Surgery, 2007
- Guidelines for the Identification, Evaluation, and Management of Systemic Hypertension in Dogs and CatsJournal of Veterinary Internal Medicine, 2007
- Effect of Control of Systolic Blood Pressure on Survival in Cats with Systemic HypertensionJournal of Veterinary Internal Medicine, 2007
- A comparison of CAT Doppler and oscillometric Memoprint machines for non-invasive blood pressure measurement in conscious catsJournal of Feline Medicine and Surgery, 2005
- Non-invasive Blood Pressure Measurements in Cats: Clinical Significance of Hypertension Associated with Chronic Renal Failure.Journal of Veterinary Medical Science, 1998
- Doppler Ultrasonographic, Oscillometric Sphygmomanometric, and Photoplethysmographic Techniques for Noninvasive Blood Pressure Measurement in Anesthetized CatsJournal of Veterinary Internal Medicine, 1995
- Spontaneous Systemic Hypertension in 24 CatsJournal of Veterinary Internal Medicine, 1994