Correcting Highly Aberrated Eyes Using Large-stroke Adaptive Optics
- 1 November 2007
- journal article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 23 (11) , 947-952
Abstract
Purpose: To investigate the optical performance of a large-stroke deformable mirror in correcting large aberrations in highly aberrated eyes. Methods: A large-stroke deformable mirror (Mirao 52D; Imagine Eyes) and a Shack-Hartmann wavefront sensor were used in an adaptive optics system. Closed-loop correction of the static aberrations of a phase plate designed for an advanced keratoconic eye was performed for a 6-mm pupil. The same adaptive optics system was also used to correct the aberrations in one eye each of two moderate keratoconic and three normal human eyes for a 6-mm pupil. Results: With closed-loop correction of the phase plate, the total root-mean-square (RMS) over a 6-mm pupil was reduced from 3.54 to 0.04 µm in 30 to 40 iterations, corresponding to 3 to 4 seconds. Adaptive optics closed-loop correction reduced an average total RMS of 1.73±0.998 to 0.10±0.017 µm (higher order RMS of 0.39±0.124 to 0.06±0.004 µm) in the three normal eyes and 2.73±1.754 to 0.10±0.001 µm (higher order RMS of 1.82±1.058 to 0.05±0.017 µm) in the two keratoconic eyes. Conclusions: Aberrations in both normal and highly aberrated eyes were successfully corrected using the large-stroke deformable mirror to provide almost perfect optical quality. This mirror can be a powerful tool to assess the limit of visual performance achievable after correcting the aberrations, especially in eyes with abnormal corneal profiles. [ J Refract Surg. 2007;23:947–952.]Keywords
This publication has 24 references indexed in Scilit:
- Characterizing the Wave Aberration in Eyes with Keratoconus or Penetrating Keratoplasty Using a High–Dynamic Range Wavefront SensorOphthalmology, 2007
- Requirements for discrete actuator and segmented wavefront correctors for aberration compensation in two large populations of human eyesApplied Optics, 2007
- High-resolution adaptive optics scanning laser ophthalmoscope with dual deformable mirrorsJournal of the Optical Society of America A, 2007
- Neural compensation for the eye’s optical aberrationsJournal of Vision, 2004
- Simulated Optical Performance of Custom Wavefront Soft Contact Lenses for KeratoconusOptometry and Vision Science, 2003
- Use of a microelectromechanical mirror for adaptive optics in the human eyeOptics Letters, 2002
- Closed-loop adaptive optics in the human eyeOptics Letters, 2001
- Phase plates for wave-aberration compensation in the human eyeOptics Letters, 2000
- Biomicroscopic Signs and Disease Severity in KeratoconusCornea, 1996
- Objective measurement of wave aberrations of the human eye with the use of a Hartmann–Shack wave-front sensorJournal of the Optical Society of America A, 1994