Ramkumar Sabesan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ramkumar Sabesan has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Geunyoung Yoon
The Institute of Optics, University of Rochester, Rochester, NY 14627, USA
4 shared publications- David R. Williams
The Institute of Optics, University of Rochester
1 shared publication - Geunyoung Yoon
The Institute of Optics, University of Rochester, Rochester, NY, USA
1 shared publication Ian G. Cox
Bausch and Lomb
1 shared publicationKamran Ahmad
The Center for Visual Science
1 shared publicationLen Zheleznyak
The Institute of Optics, University of Rochester, Rochester, NY 14627, USA
1 shared publication
Latest Publications
- Open Access
- 8 November 2012
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 3 (12) , 3176-3189
Binocular visual performance and summation after correcting higher order aberrations
Although the ocular higher order aberrations degrade the retinal image substantially, most studies have investigated their effect on vision only under monocular conditions. Here, we have investigated the impact of binocular higher order aberration correction on visual performance and binocular summation by constructing a binocular adaptive optics (AO) vision simulator. Binocular monochromatic aberration correction using AO improved visual acuity and contrast sensitivity significantly. The improvement however, differed from that achieved under monocular viewing. At high spatial frequency (24 c/deg), the monocular benefit in contrast sensitivity was significantly larger than the benefit achieved binocularly. In addition, binocular summation for higher spatial frequencies was the largest in the presence of subject’s native higher order aberrations and was reduced when these aberrations were corrected. This study thus demonstrates the vast potential of binocular AO vision testing in understanding the impact of ocular optics on habitual binocular vision.
- 8 November 2012
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 3 (12) , 3176-3189
Open AccessBinocular visual performance and summation after correcting higher order aberrations
Although the ocular higher order aberrations degrade the retinal image substantially, most studies have investigated their effect on vision only under monocular conditions. Here, we have investigated the impact of binocular higher order aberration correction on visual performance and binocular summation by constructing a binocular adaptive optics (AO) vision simulator. Binocular monochromatic aberration correction using AO improved visual acuity and contrast sensitivity significantly. The improvement however, differed from that achieved under monocular viewing. At high spatial frequency (24 c/deg), the monocular benefit in contrast sensitivity was significantly larger than the benefit achieved binocularly. In addition, binocular summation for higher spatial frequencies was the largest in the presence of subject’s native higher order aberrations and was reduced when these aberrations were corrected. This study thus demonstrates the vast potential of binocular AO vision testing in understanding the impact of ocular optics on habitual binocular vision.
- Open Access
- 1 July 2010
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 51 (7) , 3835-3839
Neural Compensation for Long-term Asymmetric Optical Blur to Improve Visual Performance in Keratoconic Eyes
Purpose.: To investigate whether long-term visual experience with irregular optical blur compensates for the impact of higher-order aberration on visual performance in keratoconic (KC) eyes. Methods.: The aberrations and high (100%)– and low (20%)–contrast tumbling E visual acuity (VA) were measured in four moderate KC eyes in which the subjects were wearing their own prescribed soft toric contact lenses over a 6-mm pupil. VA was measured in three emmetropic normal eyes for comparison with each of the four KC eyes. An adaptive optics system was used to correct the aberration of the normal eye and to induce the aberration of the KC eye simultaneously during vision testing. The magnitude of neural compensation was defined as improvement in VA in each KC eye compared with the normal eyes with KC aberrations. Results.: Mean total and higher-order root mean square errors in the KC eyes with contact lenses were 2.72 ± 0.83 μm and 1.36 ± 0.29 μm, respectively, for a 6-mm pupil. Residual RMS wavefront error in induction of KC aberrations on normal eyes was approximately 0.1 μm in all cases. Each KC eye had statistically better high (P < 0.02)– and low (P < 0.03)–contrast VA than the three normal eyes. Mean compensation for high-contrast VA in logMAR was 0.12 ± 0.09, corresponding to an improvement of 23.8%. A similar result was obtained for low-contrast VA. The magnitude of compensation increased with the severity of KC aberrations. Conclusions.: In KC eyes, the neural visual system compensates for long-term visual experience with an asymmetrically blurred retinal image, resulting in improved visual performance.
- 1 July 2010
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 51 (7) , 3835-3839
Open AccessNeural Compensation for Long-term Asymmetric Optical Blur to Improve Visual Performance in Keratoconic Eyes
Purpose.: To investigate whether long-term visual experience with irregular optical blur compensates for the impact of higher-order aberration on visual performance in keratoconic (KC) eyes. Methods.: The aberrations and high (100%)– and low (20%)–contrast tumbling E visual acuity (VA) were measured in four moderate KC eyes in which the subjects were wearing their own prescribed soft toric contact lenses over a 6-mm pupil. VA was measured in three emmetropic normal eyes for comparison with each of the four KC eyes. An adaptive optics system was used to correct the aberration of the normal eye and to induce the aberration of the KC eye simultaneously during vision testing. The magnitude of neural compensation was defined as improvement in VA in each KC eye compared with the normal eyes with KC aberrations. Results.: Mean total and higher-order root mean square errors in the KC eyes with contact lenses were 2.72 ± 0.83 μm and 1.36 ± 0.29 μm, respectively, for a 6-mm pupil. Residual RMS wavefront error in induction of KC aberrations on normal eyes was approximately 0.1 μm in all cases. Each KC eye had statistically better high (P < 0.02)– and low (P < 0.03)–contrast VA than the three normal eyes. Mean compensation for high-contrast VA in logMAR was 0.12 ± 0.09, corresponding to an improvement of 23.8%. A similar result was obtained for low-contrast VA. The magnitude of compensation increased with the severity of KC aberrations. Conclusions.: In KC eyes, the neural visual system compensates for long-term visual experience with an asymmetrically blurred retinal image, resulting in improved visual performance.
- Open Access
- 1 May 2009
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 9 (5) , 6
Visual performance after correcting higher order aberrations in keratoconic eyes
Keratoconic eyes are affected by an irregular optical blur induced by significant magnitude of higher order aberrations (HOAs). Although it is expected that correction of ocular aberrations leads to an improvement in visual performance, keratoconic eyes might not achieve the visual benefit predicted by optical theory because of long-term adaptation to poor retinal image quality. To investigate this, an adaptive optics (AO) system equipped with a large-stroke deformable mirror and a Shack–Hartmann wavefront sensor was used to correct the aberrations and measure high contrast tumbling E visual acuity (HCVA) in 8 keratoconic eyes. Eight normal eyes were employed as control. Aberrations were dynamically corrected with closed-loop AO during visual acuity testing, with residual root-mean-square error of around 0.1 μm in both groups over 6-mm pupil ( p = 0.11). With AO correction, the HCVA in logMAR was −0.26 ± 0.063 in normal eyes, and in keratoconic eyes, it was −0.07 ± 0.051 ( p = 0.0001) for the same pupil size. There was no correlation in the AO-corrected HCVA for normals with the magnitudes of their native HOA. However, within keratoconic eyes, poorer AO-corrected HCVA was observed with an increase of the native magnitudes of HOA ( R 2 = 0.67). This may indicate that long-term visual experience with poor retinal image quality, induced by HOA, may restrict the visual benefit achievable immediately after correction in keratoconic eyes.
- 1 May 2009
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 9 (5) , 6
Open AccessVisual performance after correcting higher order aberrations in keratoconic eyes
Keratoconic eyes are affected by an irregular optical blur induced by significant magnitude of higher order aberrations (HOAs). Although it is expected that correction of ocular aberrations leads to an improvement in visual performance, keratoconic eyes might not achieve the visual benefit predicted by optical theory because of long-term adaptation to poor retinal image quality. To investigate this, an adaptive optics (AO) system equipped with a large-stroke deformable mirror and a Shack–Hartmann wavefront sensor was used to correct the aberrations and measure high contrast tumbling E visual acuity (HCVA) in 8 keratoconic eyes. Eight normal eyes were employed as control. Aberrations were dynamically corrected with closed-loop AO during visual acuity testing, with residual root-mean-square error of around 0.1 μm in both groups over 6-mm pupil ( p = 0.11). With AO correction, the HCVA in logMAR was −0.26 ± 0.063 in normal eyes, and in keratoconic eyes, it was −0.07 ± 0.051 ( p = 0.0001) for the same pupil size. There was no correlation in the AO-corrected HCVA for normals with the magnitudes of their native HOA. However, within keratoconic eyes, poorer AO-corrected HCVA was observed with an increase of the native magnitudes of HOA ( R 2 = 0.67). This may indicate that long-term visual experience with poor retinal image quality, induced by HOA, may restrict the visual benefit achievable immediately after correction in keratoconic eyes.
- 1 November 2007
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 23 (11) , 947-952
Correcting Highly Aberrated Eyes Using Large-stroke Adaptive Optics
Purpose: To investigate the optical performance of a large-stroke deformable mirror in correcting large aberrations in highly aberrated eyes. Methods: A large-stroke deformable mirror (Mirao 52D; Imagine Eyes) and a Shack-Hartmann wavefront sensor were used in an adaptive optics system. Closed-loop correction of the static aberrations of a phase plate designed for an advanced keratoconic eye was performed for a 6-mm pupil. The same adaptive optics system was also used to correct the aberrations in one eye each of two moderate keratoconic and three normal human eyes for a 6-mm pupil. Results: With closed-loop correction of the phase plate, the total root-mean-square (RMS) over a 6-mm pupil was reduced from 3.54 to 0.04 µm in 30 to 40 iterations, corresponding to 3 to 4 seconds. Adaptive optics closed-loop correction reduced an average total RMS of 1.73±0.998 to 0.10±0.017 µm (higher order RMS of 0.39±0.124 to 0.06±0.004 µm) in the three normal eyes and 2.73±1.754 to 0.10±0.001 µm (higher order RMS of 1.82±1.058 to 0.05±0.017 µm) in the two keratoconic eyes. Conclusions: Aberrations in both normal and highly aberrated eyes were successfully corrected using the large-stroke deformable mirror to provide almost perfect optical quality. This mirror can be a powerful tool to assess the limit of visual performance achievable after correcting the aberrations, especially in eyes with abnormal corneal profiles. [ J Refract Surg. 2007;23:947–952.]
- 1 November 2007
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 23 (11) , 947-952
Correcting Highly Aberrated Eyes Using Large-stroke Adaptive Optics
Purpose: To investigate the optical performance of a large-stroke deformable mirror in correcting large aberrations in highly aberrated eyes. Methods: A large-stroke deformable mirror (Mirao 52D; Imagine Eyes) and a Shack-Hartmann wavefront sensor were used in an adaptive optics system. Closed-loop correction of the static aberrations of a phase plate designed for an advanced keratoconic eye was performed for a 6-mm pupil. The same adaptive optics system was also used to correct the aberrations in one eye each of two moderate keratoconic and three normal human eyes for a 6-mm pupil. Results: With closed-loop correction of the phase plate, the total root-mean-square (RMS) over a 6-mm pupil was reduced from 3.54 to 0.04 µm in 30 to 40 iterations, corresponding to 3 to 4 seconds. Adaptive optics closed-loop correction reduced an average total RMS of 1.73±0.998 to 0.10±0.017 µm (higher order RMS of 0.39±0.124 to 0.06±0.004 µm) in the three normal eyes and 2.73±1.754 to 0.10±0.001 µm (higher order RMS of 1.82±1.058 to 0.05±0.017 µm) in the two keratoconic eyes. Conclusions: Aberrations in both normal and highly aberrated eyes were successfully corrected using the large-stroke deformable mirror to provide almost perfect optical quality. This mirror can be a powerful tool to assess the limit of visual performance achievable after correcting the aberrations, especially in eyes with abnormal corneal profiles. [ J Refract Surg. 2007;23:947–952.]
- 19 March 2007
- Published by Optica Publishing Group in Optics Letters
- Vol. 32 (8) , 1000-1002
Vision improvement by correcting higher-order aberrations with customized soft contact lenses in keratoconic eyes
Higher-order aberration correction in abnormal eyes can result in significant vision improvement, especially in eyes with abnormal corneas. Customized optics such as phase plates and customized contact lenses are one of the most practical, nonsurgical ways to correct these ocular higher-order aberrations. We demonstrate the feasibility of correcting higher-order aberrations and improving visual performance with customized soft contact lenses in keratoconic eyes while compensating for the static decentration and rotation of the lens. A reduction of higher-order aberrations by a factor of 3 on average was obtained in these eyes. The higher-order aberration correction resulted in an average improvement of 2.1 lines in visual acuity over the conventional correction of defocus and astigmatism alone.
- 19 March 2007
- Published by Optica Publishing Group in Optics Letters
- Vol. 32 (8) , 1000-1002
Vision improvement by correcting higher-order aberrations with customized soft contact lenses in keratoconic eyes
Higher-order aberration correction in abnormal eyes can result in significant vision improvement, especially in eyes with abnormal corneas. Customized optics such as phase plates and customized contact lenses are one of the most practical, nonsurgical ways to correct these ocular higher-order aberrations. We demonstrate the feasibility of correcting higher-order aberrations and improving visual performance with customized soft contact lenses in keratoconic eyes while compensating for the static decentration and rotation of the lens. A reduction of higher-order aberrations by a factor of 3 on average was obtained in these eyes. The higher-order aberration correction resulted in an average improvement of 2.1 lines in visual acuity over the conventional correction of defocus and astigmatism alone.