Ultrashort echo time pulse sequences for visualization of deep peripheral fasciae and epimysium in porcine models with histologic correlations
Authors:
Open Access
- 1 December 2023
- journal article
- research article
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 13 (12) , 8447-8461
Abstract
Background: The deep peripheral fascia and epimysium are vital for muscle and tendon support, but their tight proton composition results in hypointense signals in conventional spin echo sequences. Ultrashort echo time (UTE) magnetic resonance imaging (MRI), using microsecond TE values, may visualize these structures. The purpose of this study was to evaluate whether UTE pulse sequence with a three-dimensional cone trajectory (3D UTE), with or without fat suppression (FS), can be used to visualize the fascia and epimysium using porcine lower legs as an example. Methods: The anterior soft tissues of porcine lower legs were dissected and partially separated into distinct layers to expose the deep peripheral fascia, epimysium, and muscle. Axial 3D UTE and 3D UTE FS imaging using dual-echo acquisition and echo subtraction were performed both before and after dissection. Prior to dissection, the thickness, signal-to-noise ratios (SNRs), and contrast-to-noise ratios (CNRs) of structures believed to be deep peripheral fascia and epimysium were measured in both 3D UTE and 3D UTE FS. Post-dissection images were also analyzed to measure the SNRs and CNRs for the deep peripheral fascia and epimysium. Histological evaluations were carried out to verify the identities of the deep peripheral fascia and epimysium, as well as their thickness, and these measurements were compared to imaging findings. Results: In pre-dissection images obtained with 3D UTE and 3D UTE FS, both the deep peripheral fascia and epimysium exhibited high signal intensity. In the subtraction images, the mean thickness of the deep fascia was 0.87 mm, and that of the epimysium was 0.80 mm when imaged with 3D UTE. This is compared to measurements of 0.77 and 0.22 mm in 3D UTE FS, respectively. Histological analyses confirmed the thickness of the deep peripheral fascia and epimysium as 0.65 and 0.14 mm, respectively. In the post-dissection images, the deep fascia continued to display high signal intensity when compared with adjacent soft tissues, consistent with the histological findings. Meanwhile, the epimysium showed very low CNRs. Conclusions: 3D UTE and 3D UTE FS can be used to visualize the deep peripheral fascia with high signal intensity and contrast but are insufficient to show signal intensity in the epimysium.Keywords
This publication has 31 references indexed in Scilit:
- Morphology of the Cartilaginous Endplates in Human Intervertebral Disks with Ultrashort Echo Time MR ImagingRadiology, 2013
- The muscular force transmission system: Role of the intramuscular connective tissueJournal of Bodywork and Movement Therapies, 2013
- Meniscal Calcifications: Morphologic and Quantitative Evaluation by using 2D Inversion-Recovery Ultrashort Echo Time and 3D Ultrashort Echo Time 3.0-T MR Imaging Techniques—Feasibility StudyRadiology, 2012
- Short T2 contrast with three-dimensional ultrashort echo time imagingMagnetic Resonance Imaging, 2011
- Ultrashort Echo Time MR Imaging of Osteochondral Junction of the Knee at 3 T: Identification of Anatomic Structures Contributing to Signal IntensityRadiology, 2010
- The fascia of the limbs and back – a reviewJournal of Anatomy, 2008
- Histological study of the deep fasciae of the limbsJournal of Bodywork and Movement Therapies, 2008
- Magnetic resonance imaging with ultrashort TE (UTE) PULSE sequences: Technical considerationsJournal of Magnetic Resonance Imaging, 2007
- Designing long‐T2 suppression pulses for ultrashort echo time imagingMagnetic Resonance in Medicine, 2006
- Measurement ofR′2in the Presence of Multiple Spectral Components Using Reference Spectrum DeconvolutionJournal of Magnetic Resonance, 1998