Yeo Ju Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yeo Ju Kim has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
- Seunghun Lee
Department of Radiology, Hanyang University School of Medicine, Seoul Hospital, Seoul, Korea
9 shared publications - Jeong Ah Ryu
Department of Radiology, Hanyang University School of Medicine, Guri Hospital, Guri, Korea
7 shared publications Seunghun Lee
Hanyang Univ, Coll Med, Dept Radiol, Seoul, South Korea
4 shared publications- Choong Guen Chee
Department of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea
2 shared publications - Eugene Lee
College of Medicine, Seoul National University, Seoul, Republic of Korea
2 shared publications Hyungseok Jang
2 shared publications
Latest Publications
- Open Access
- 11 May 2026
- Published by Oxford University Press (OUP) in Radiology Advances
- Vol. 3 (3) , umag026
Standardizing attenuation across tube voltages and vertebral levels for opportunistic osteoporosis screening on low-dose chest CT
Background: Opportunistic screening of osteoporosis on CT has emerged as a cost-effective strategy for bone health assessment. However, vertebral attenuation varies substantially with CT tube voltage and spinal level, limiting standardization. Purpose: To model and standardize vertebral attenuation across tube voltages and spinal levels on low-dose chest CT for opportunistic osteoporosis screening. Materials and Methods: This retrospective study included 589 patients (336 women; mean age ± standard deviation, 65.9 ± 12.4 years) who underwent 2 noncontrast low-dose chest CT examinations and 1 dual-energy X-ray absorptiometry within 3 months. Vertebral attenuation was measured at T10–L2 on CT using a deep learning-based software (AVIEW SpineBH, Coreline Soft). Osteoporosis was diagnosed using dual-energy X-ray absorptiometry. A linear mixed-effects model regressed attenuation on the logarithm of tube voltage, incorporating fixed effects for spinal level (T10–L2) and patient-specific random effects. Model performance was evaluated by converting the L1–120 kVp reference to other tube-voltage–level combinations and comparing predicted with observed attenuation using Pearson correlation, mean bias, and 95% limits of agreement. Diagnostic applicability was assessed by comparing receiver operating characteristic–derived thresholds with model-predicted thresholds converted from the reference. Results: Vertebral attenuation decreased by approximately 6–11 Hounsfield units (HU) for every 10-kVp increase (β = −88.8 HU per log[kVp]; P < .001) and declined by approximately 4–14 HU per level from T10 to L2. Predicted values closely matched observed measurements (r = 0.89; mean bias, 2.2 HU; 95% limits of agreement, –54 to 59 HU). The model-predicted thresholds showed strong agreement with receiver operating characteristic–derived thresholds, differing by 1–10 HU across tube voltages and spinal levels. Conclusions: A log-linear mixed-effects model enables population-level standardization of vertebral attenuation across tube voltages and spinal levels, supporting the development of more consistent opportunistic CT-based osteoporosis screening methods on noncontrast chest CT.
- 11 May 2026
- Published by Oxford University Press (OUP) in Radiology Advances
- Vol. 3 (3) , umag026
Open AccessStandardizing attenuation across tube voltages and vertebral levels for opportunistic osteoporosis screening on low-dose chest CT
Background: Opportunistic screening of osteoporosis on CT has emerged as a cost-effective strategy for bone health assessment. However, vertebral attenuation varies substantially with CT tube voltage and spinal level, limiting standardization. Purpose: To model and standardize vertebral attenuation across tube voltages and spinal levels on low-dose chest CT for opportunistic osteoporosis screening. Materials and Methods: This retrospective study included 589 patients (336 women; mean age ± standard deviation, 65.9 ± 12.4 years) who underwent 2 noncontrast low-dose chest CT examinations and 1 dual-energy X-ray absorptiometry within 3 months. Vertebral attenuation was measured at T10–L2 on CT using a deep learning-based software (AVIEW SpineBH, Coreline Soft). Osteoporosis was diagnosed using dual-energy X-ray absorptiometry. A linear mixed-effects model regressed attenuation on the logarithm of tube voltage, incorporating fixed effects for spinal level (T10–L2) and patient-specific random effects. Model performance was evaluated by converting the L1–120 kVp reference to other tube-voltage–level combinations and comparing predicted with observed attenuation using Pearson correlation, mean bias, and 95% limits of agreement. Diagnostic applicability was assessed by comparing receiver operating characteristic–derived thresholds with model-predicted thresholds converted from the reference. Results: Vertebral attenuation decreased by approximately 6–11 Hounsfield units (HU) for every 10-kVp increase (β = −88.8 HU per log[kVp]; P < .001) and declined by approximately 4–14 HU per level from T10 to L2. Predicted values closely matched observed measurements (r = 0.89; mean bias, 2.2 HU; 95% limits of agreement, –54 to 59 HU). The model-predicted thresholds showed strong agreement with receiver operating characteristic–derived thresholds, differing by 1–10 HU across tube voltages and spinal levels. Conclusions: A log-linear mixed-effects model enables population-level standardization of vertebral attenuation across tube voltages and spinal levels, supporting the development of more consistent opportunistic CT-based osteoporosis screening methods on noncontrast chest CT.
- 13 April 2026
- Published by Springer Nature in Skeletal Radiology
- Vol. 55 (7) , 1663-1672
Image quality evaluation of decubitus lumbar spine MRI using a flexible coil and PROPELLER sequence: comparison with conventional supine MRI
To evaluate image quality of decubitus lumbar spine MRI using a flexible coil with or without Periodically Rotated Overlapping Parallel Lines with Enhanced Reconstruction (PROPELLER) sequence compared to that of the conventional supine lumbar spine MRI. This study was conducted on patients who underwent decubitus lumbar spine MRI applying a flexible coil at a single center between February 1 and March 11, 2025, and had a Numeric Rating Scale (NRS) pain score ≥ 5, while examining supine MRI. Signal-to-noise ratio (SNR) in T2-weighted fast-spin-echo (FSE) sequence for supine, decubitus, and PROPELLER sequence at decubitus position were measured and compared using the Wilcoxon signed-rank test. Two radiologists independently evaluated the subjective image quality of each spine MRI. A total of 35 patients (mean age, 66 ± 13 years) were included in our study. On T2-weighted sagittal images, cerebrospinal fluid (CSF) SNR was highest in the supineFSE (589.3, 95% CI: 482.1-695.1) and significantly lower in both decubitusFSE (431.2, 95% CI: 365.9-479.9) and decubitusPROPELLER (417.8, 95% CI: 389.2-439.1) (p < 0.001). On T2-weighted axial images, SNRCSF values of supineFSE (284.6, 95% CI: 256.4-331.0) and decubitusPROPELLER (245.0, 95% CI: 215.7-336.1) were both statistically higher than that of decubitusFSE (176.1, 95% CI: 135.9-209.2) (p < 0.001). In qualitative analysis, there was no statistical difference across supineFSE, decubitusFSE, and decubitusPROPELLER. Image quality of decubitus lumbar spine MRI using a flexible coil was clinically feasible with acceptable image quality. PROPELLER sequence improved SNRCSF on axial images in decubitus position.
- 13 April 2026
- Published by Springer Nature in Skeletal Radiology
- Vol. 55 (7) , 1663-1672
Image quality evaluation of decubitus lumbar spine MRI using a flexible coil and PROPELLER sequence: comparison with conventional supine MRI
To evaluate image quality of decubitus lumbar spine MRI using a flexible coil with or without Periodically Rotated Overlapping Parallel Lines with Enhanced Reconstruction (PROPELLER) sequence compared to that of the conventional supine lumbar spine MRI. This study was conducted on patients who underwent decubitus lumbar spine MRI applying a flexible coil at a single center between February 1 and March 11, 2025, and had a Numeric Rating Scale (NRS) pain score ≥ 5, while examining supine MRI. Signal-to-noise ratio (SNR) in T2-weighted fast-spin-echo (FSE) sequence for supine, decubitus, and PROPELLER sequence at decubitus position were measured and compared using the Wilcoxon signed-rank test. Two radiologists independently evaluated the subjective image quality of each spine MRI. A total of 35 patients (mean age, 66 ± 13 years) were included in our study. On T2-weighted sagittal images, cerebrospinal fluid (CSF) SNR was highest in the supineFSE (589.3, 95% CI: 482.1-695.1) and significantly lower in both decubitusFSE (431.2, 95% CI: 365.9-479.9) and decubitusPROPELLER (417.8, 95% CI: 389.2-439.1) (p < 0.001). On T2-weighted axial images, SNRCSF values of supineFSE (284.6, 95% CI: 256.4-331.0) and decubitusPROPELLER (245.0, 95% CI: 215.7-336.1) were both statistically higher than that of decubitusFSE (176.1, 95% CI: 135.9-209.2) (p < 0.001). In qualitative analysis, there was no statistical difference across supineFSE, decubitusFSE, and decubitusPROPELLER. Image quality of decubitus lumbar spine MRI using a flexible coil was clinically feasible with acceptable image quality. PROPELLER sequence improved SNRCSF on axial images in decubitus position.
- Open Access
- 1 January 2026
- Published by XMLink in Journal of the Korean Society of Radiology
- Vol. 87 (1) , 54-72
Musculoskeletal Complications in Rheumatic Diseases
이승훈, et al. J Korean Soc Radiol. 2026 Jan;87:e3. https://doi.org/10.3348/jksr.2025.0051
- 1 January 2026
- Published by XMLink in Journal of the Korean Society of Radiology
- Vol. 87 (1) , 54-72
Open AccessMusculoskeletal Complications in Rheumatic Diseases
이승훈, et al. J Korean Soc Radiol. 2026 Jan;87:e3. https://doi.org/10.3348/jksr.2025.0051
- Open Access
- 1 January 2025
- Published by XMLink in Investigative Magnetic Resonance Imaging
- Vol. 29 (3) , 145-158
Metal Artifacts in Postoperative Spine MRI: Strategies and Limitations
Kim YJ, et al. Investig Magn Reson Imaging. 2025 Sep;29(3):145-158. https://doi.org/10.13104/imri.2025.0017
- 1 January 2025
- Published by XMLink in Investigative Magnetic Resonance Imaging
- Vol. 29 (3) , 145-158
Open AccessMetal Artifacts in Postoperative Spine MRI: Strategies and Limitations
Kim YJ, et al. Investig Magn Reson Imaging. 2025 Sep;29(3):145-158. https://doi.org/10.13104/imri.2025.0017
- 1 December 2024
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 313 (3) , e232363
Osteochondral Abnormalities on Three-Dimensional Ultrashort Echo Time MRI Scans Are Associated with Knee Cartilage Degradation
Three-dimensional ultrashort echo-time MRI showed calcified cartilage and subchondral bone plate abnormalities that were associated with cartilage degradation and osteochondral junction abnormalities at knee proton-density fat-saturated MRI.
- 1 December 2024
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 313 (3) , e232363
Osteochondral Abnormalities on Three-Dimensional Ultrashort Echo Time MRI Scans Are Associated with Knee Cartilage Degradation
Three-dimensional ultrashort echo-time MRI showed calcified cartilage and subchondral bone plate abnormalities that were associated with cartilage degradation and osteochondral junction abnormalities at knee proton-density fat-saturated MRI.
- Open Access
- 15 March 2024
- Published by The Journal of Rheumatology in The Journal of Rheumatology
- Vol. 51 (10)
A Rare Diagnosis of Infiltrative Muscle Disease in a Patient With Multiple Joint Pain and Fever
Hemophagocytic lymphohistiocytosis (HLH) is characterized by excessive immune activation.1It involves the activation of lymphocytes and histiocytes that infiltrate various organs and release cytokines.1
- 15 March 2024
- Published by The Journal of Rheumatology in The Journal of Rheumatology
- Vol. 51 (10)
Open AccessA Rare Diagnosis of Infiltrative Muscle Disease in a Patient With Multiple Joint Pain and Fever
Hemophagocytic lymphohistiocytosis (HLH) is characterized by excessive immune activation.1It involves the activation of lymphocytes and histiocytes that infiltrate various organs and release cytokines.1
- Open Access
- 28 January 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (3) , 283
The Relationship between Types of Os Trigonum and Findings of Conventional Ankle Magnetic Resonance Imaging: A Study Based on Three-Dimensional Magnetic Resonance Imaging
This study aimed to investigate the dimensions and types of the os trigonum and evaluate their relationship with various pathologic conditions on the posterior ankle using ankle MRI images. A total of 124 non-contrast-enhanced ankle and foot MR images of 123 consecutive patients were included in this retrospective study. The images were presented randomly, and they contained no patient information. The MR images were retrospectively and independently reviewed by two reviewers with a fellowship-trained musculoskeletal radiologist. The images were classified as type I and II based on the ossicle’s medial border overlying the talus’s posterior process and the groove for the flexor hallucis longus tendon (FHL). The study revealed that patients with type II os trigonum had a longer transverse diameter of the ossicle than type I, and there were statistically significant differences. Detachment status tended to be less in type I than in type II os trigonum, and the differences between the groups were statistically significant. There were no significant differences between type I and II os trigonum regarding posterior talofibular ligament (PTFL) abnormality, bone marrow edema, FHL tenosynovitis, and posterior synovitis. The study concluded that the os trigonum is a common cause of posterior ankle impingement, and type II os trigonum has a longer transverse diameter of the ossicle than type I.
- 28 January 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (3) , 283
Open AccessThe Relationship between Types of Os Trigonum and Findings of Conventional Ankle Magnetic Resonance Imaging: A Study Based on Three-Dimensional Magnetic Resonance Imaging
This study aimed to investigate the dimensions and types of the os trigonum and evaluate their relationship with various pathologic conditions on the posterior ankle using ankle MRI images. A total of 124 non-contrast-enhanced ankle and foot MR images of 123 consecutive patients were included in this retrospective study. The images were presented randomly, and they contained no patient information. The MR images were retrospectively and independently reviewed by two reviewers with a fellowship-trained musculoskeletal radiologist. The images were classified as type I and II based on the ossicle’s medial border overlying the talus’s posterior process and the groove for the flexor hallucis longus tendon (FHL). The study revealed that patients with type II os trigonum had a longer transverse diameter of the ossicle than type I, and there were statistically significant differences. Detachment status tended to be less in type I than in type II os trigonum, and the differences between the groups were statistically significant. There were no significant differences between type I and II os trigonum regarding posterior talofibular ligament (PTFL) abnormality, bone marrow edema, FHL tenosynovitis, and posterior synovitis. The study concluded that the os trigonum is a common cause of posterior ankle impingement, and type II os trigonum has a longer transverse diameter of the ossicle than type I.
- Open Access
- 2 January 2024
- Published by Springer Nature in BMC Medical Imaging
- Vol. 24 (1) , 1-11
Comparison of the diagnostic performance of the Swischuk line method and the anterior atlantodental interval method in atlantodental subluxation
Background: Atlantodental subluxation (ADS) is a serious condition that can result in sudden death. Measuring the anterior atlantodental interval (AADI method) is the gold standard for diagnosis but the complex anatomy of this region can make diagnosis difficult, especially for beginners. Therefore, we would like to use a simpler method, the Swischuk line method, to diagnose ADS. The purpose of our study was to evaluate the diagnostic performance of the Swischuk line method for ADS on lateral cervical spine radiographs compared to the AADI method. Methods: A retrospective study was conducted with patients who presented with ADS (ADS group, n = 32, mean age 57.78 years, age range 34–82 years, 10 men, 21 women) and an age- and sex-matched control group (n = 32). The diagnostic performance of the AADI method and the Swischuk line method for ADS was assessed using lateral cervical radiographs in both flexion and neutral postures by an experienced musculoskeletal radiologist (reader 1), a senior resident (reader 2), and a junior resident (reader 3) in the radiologic department. Results: In the flexion posture, the AADI method and the Swischuk line method showed excellent diagnostic performance with AUCs > 0.9 for readers 1 2 and reader 3. In a neutral posture, the diagnostic performance of the AADI and Swischuk line methods was decreased. With a 1 mm cut-off value using the Swischuk line method in flexion posture, the sensitivity was 75% or more, the specificity was 100%, and the accuracy was 87.50% or more 90.63% for all readers. With a 2 mm cut-off value, the sensitivity was low (37.50-46.88%) but the specificity was 100% for all three readers. In a neutral posture, the sensitivity for both methods decreased, though specificity remained high (> 80%). Conclusions: The Swischuk line method was found to be reliable and showed high sensitivity and specificity with a cut-off value of 1 mm for the diagnosis of ADS in cervical lateral radiographs in flexion posture. It can be used as a complement to the AADI method.
- 2 January 2024
- Published by Springer Nature in BMC Medical Imaging
- Vol. 24 (1) , 1-11
Open AccessComparison of the diagnostic performance of the Swischuk line method and the anterior atlantodental interval method in atlantodental subluxation
Background: Atlantodental subluxation (ADS) is a serious condition that can result in sudden death. Measuring the anterior atlantodental interval (AADI method) is the gold standard for diagnosis but the complex anatomy of this region can make diagnosis difficult, especially for beginners. Therefore, we would like to use a simpler method, the Swischuk line method, to diagnose ADS. The purpose of our study was to evaluate the diagnostic performance of the Swischuk line method for ADS on lateral cervical spine radiographs compared to the AADI method. Methods: A retrospective study was conducted with patients who presented with ADS (ADS group, n = 32, mean age 57.78 years, age range 34–82 years, 10 men, 21 women) and an age- and sex-matched control group (n = 32). The diagnostic performance of the AADI method and the Swischuk line method for ADS was assessed using lateral cervical radiographs in both flexion and neutral postures by an experienced musculoskeletal radiologist (reader 1), a senior resident (reader 2), and a junior resident (reader 3) in the radiologic department. Results: In the flexion posture, the AADI method and the Swischuk line method showed excellent diagnostic performance with AUCs > 0.9 for readers 1 2 and reader 3. In a neutral posture, the diagnostic performance of the AADI and Swischuk line methods was decreased. With a 1 mm cut-off value using the Swischuk line method in flexion posture, the sensitivity was 75% or more, the specificity was 100%, and the accuracy was 87.50% or more 90.63% for all readers. With a 2 mm cut-off value, the sensitivity was low (37.50-46.88%) but the specificity was 100% for all three readers. In a neutral posture, the sensitivity for both methods decreased, though specificity remained high (> 80%). Conclusions: The Swischuk line method was found to be reliable and showed high sensitivity and specificity with a cut-off value of 1 mm for the diagnosis of ADS in cervical lateral radiographs in flexion posture. It can be used as a complement to the AADI method.
- Open Access
- 1 January 2024
- Published by XMLink in Journal of the Korean Society of Radiology
- Vol. 85 (1) , 171-183
Preoperative Shoulder MRI Findings to Predict Subscapularis Tendon Tear Requiring Surgical Repair
정지훈, et al. J Korean Soc Radiol. 2024 Jan;85(1):171-183. https://doi.org/10.3348/jksr.2023.0050
- 1 January 2024
- Published by XMLink in Journal of the Korean Society of Radiology
- Vol. 85 (1) , 171-183
Open AccessPreoperative Shoulder MRI Findings to Predict Subscapularis Tendon Tear Requiring Surgical Repair
정지훈, et al. J Korean Soc Radiol. 2024 Jan;85(1):171-183. https://doi.org/10.3348/jksr.2023.0050
- Open Access
- 1 December 2023
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 13 (12) , 8447-8461
Ultrashort echo time pulse sequences for visualization of deep peripheral fasciae and epimysium in porcine models with histologic correlations
Background: The deep peripheral fascia and epimysium are vital for muscle and tendon support, but their tight proton composition results in hypointense signals in conventional spin echo sequences. Ultrashort echo time (UTE) magnetic resonance imaging (MRI), using microsecond TE values, may visualize these structures. The purpose of this study was to evaluate whether UTE pulse sequence with a three-dimensional cone trajectory (3D UTE), with or without fat suppression (FS), can be used to visualize the fascia and epimysium using porcine lower legs as an example. Methods: The anterior soft tissues of porcine lower legs were dissected and partially separated into distinct layers to expose the deep peripheral fascia, epimysium, and muscle. Axial 3D UTE and 3D UTE FS imaging using dual-echo acquisition and echo subtraction were performed both before and after dissection. Prior to dissection, the thickness, signal-to-noise ratios (SNRs), and contrast-to-noise ratios (CNRs) of structures believed to be deep peripheral fascia and epimysium were measured in both 3D UTE and 3D UTE FS. Post-dissection images were also analyzed to measure the SNRs and CNRs for the deep peripheral fascia and epimysium. Histological evaluations were carried out to verify the identities of the deep peripheral fascia and epimysium, as well as their thickness, and these measurements were compared to imaging findings. Results: In pre-dissection images obtained with 3D UTE and 3D UTE FS, both the deep peripheral fascia and epimysium exhibited high signal intensity. In the subtraction images, the mean thickness of the deep fascia was 0.87 mm, and that of the epimysium was 0.80 mm when imaged with 3D UTE. This is compared to measurements of 0.77 and 0.22 mm in 3D UTE FS, respectively. Histological analyses confirmed the thickness of the deep peripheral fascia and epimysium as 0.65 and 0.14 mm, respectively. In the post-dissection images, the deep fascia continued to display high signal intensity when compared with adjacent soft tissues, consistent with the histological findings. Meanwhile, the epimysium showed very low CNRs. Conclusions: 3D UTE and 3D UTE FS can be used to visualize the deep peripheral fascia with high signal intensity and contrast but are insufficient to show signal intensity in the epimysium.
- 1 December 2023
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 13 (12) , 8447-8461
Open AccessUltrashort echo time pulse sequences for visualization of deep peripheral fasciae and epimysium in porcine models with histologic correlations
Background: The deep peripheral fascia and epimysium are vital for muscle and tendon support, but their tight proton composition results in hypointense signals in conventional spin echo sequences. Ultrashort echo time (UTE) magnetic resonance imaging (MRI), using microsecond TE values, may visualize these structures. The purpose of this study was to evaluate whether UTE pulse sequence with a three-dimensional cone trajectory (3D UTE), with or without fat suppression (FS), can be used to visualize the fascia and epimysium using porcine lower legs as an example. Methods: The anterior soft tissues of porcine lower legs were dissected and partially separated into distinct layers to expose the deep peripheral fascia, epimysium, and muscle. Axial 3D UTE and 3D UTE FS imaging using dual-echo acquisition and echo subtraction were performed both before and after dissection. Prior to dissection, the thickness, signal-to-noise ratios (SNRs), and contrast-to-noise ratios (CNRs) of structures believed to be deep peripheral fascia and epimysium were measured in both 3D UTE and 3D UTE FS. Post-dissection images were also analyzed to measure the SNRs and CNRs for the deep peripheral fascia and epimysium. Histological evaluations were carried out to verify the identities of the deep peripheral fascia and epimysium, as well as their thickness, and these measurements were compared to imaging findings. Results: In pre-dissection images obtained with 3D UTE and 3D UTE FS, both the deep peripheral fascia and epimysium exhibited high signal intensity. In the subtraction images, the mean thickness of the deep fascia was 0.87 mm, and that of the epimysium was 0.80 mm when imaged with 3D UTE. This is compared to measurements of 0.77 and 0.22 mm in 3D UTE FS, respectively. Histological analyses confirmed the thickness of the deep peripheral fascia and epimysium as 0.65 and 0.14 mm, respectively. In the post-dissection images, the deep fascia continued to display high signal intensity when compared with adjacent soft tissues, consistent with the histological findings. Meanwhile, the epimysium showed very low CNRs. Conclusions: 3D UTE and 3D UTE FS can be used to visualize the deep peripheral fascia with high signal intensity and contrast but are insufficient to show signal intensity in the epimysium.