Efficacy of Dural Sealant System for Preventing Brain Shift and Improving Accuracy in Deep Brain Stimulation Surgery
Authors:
Open Access
- 1 January 2018
- journal article
- research article
- Published by Japan Neurosurgical Society in Neurologia medico-chirurgica
- Vol. 58 (5) , 199-205
Abstract
The success of deep brain stimulation (DBS) depends heavily on surgical accuracy, and brain shift is recognized as a significant factor influencing accuracy. We investigated the factors associated with surgical accuracy and showed the effectiveness of a dural sealant system for preventing brain shift in 32 consecutive cases receiving DBS. Thirty-two patients receiving DBS between March 2014 and May 2015 were included in this study. We employed conventional burr hole techniques for the first 18 cases (Group I) and a dural sealant system (DuraSeal) for the subsequent 14 cases (Group II). We measured gaps between the actual positions of electrodes and the predetermined target positions. We then retrospectively evaluated the factors involved in surgical accuracy. The average gap between an electrode’s actual and target positions was 1.55 ± 0.83 mm in all cases. Postoperative subdural air volume e, the only factor associated with surgical accuracy (r = 0.536, P < 0.0001), was significantly smaller in Group II (Group I: 43.9 ± 27.7, Group II: 12.1 ± 12.5 ml, P = 0.0006). The average electrode position gap was also significantly smaller in Group II (Group I: 1.77 ± 0.91, Group II: 1.27 ± 0.59 mm, P = 0.035). Use of a dural sealant system could significantly reduce intracranial air volume, which should improve surgical accuracy.Keywords
This publication has 21 references indexed in Scilit:
- Simple Solution for Preventing Cerebrospinal Fluid Loss and Brain Shift During Multitrack Deep Brain Stimulation Surgery in the Semisupine Position: Polyethylene Glycol Hydrogel Dural Sealant CappingNeurologia medico-chirurgica, 2013
- Postoperative Curving and Upward Displacement of Deep Brain Stimulation Electrodes Caused by Brain ShiftNeurosurgery, 2010
- Direction and Predictive Factors for the Shift of Brain Structure During Deep Brain Stimulation Electrode Implantation for Advanced Parkinson’s DiseaseNeuromodulation: Technology at the Neural Interface, 2008
- Direct Localization of Subthalamic Nucleus Supplemented by Single-Track Electrophysiological Guidance in Deep Brain Stimulation Lead Implantation: Techniques and Clinical ResultsStereotactic and Functional Neurosurgery, 2008
- Cortical and subcortical brain shift during stereotactic proceduresJournal of Neurosurgery, 2007
- Brain shift: an error factor during implantation of deep brain stimulation electrodesJournal of Neurosurgery, 2007
- Brain shift: an error factor during implantation of deep brain stimulation electrodesJournal of Neurosurgery, 2007
- Cortical and subcortical brain shift during stereotactic proceduresJournal of Neurosurgery, 2007
- Use of a Novel Absorbable Hydrogel for Augmentation of Dural Repair: Results of a Preliminary Clinical StudyOperative Neurosurgery, 2005
- MRI-Directed Subthalamic Nucleus Surgery for Parkinson’s DiseaseStereotactic and Functional Neurosurgery, 2002