Biomechanical study of the stiffness of the femoral locking compression plate of an external fixator for lower tibial fractures
Authors:
Open Access
- 18 January 2023
- journal article
- research article
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 24 (1) , 1-10
Abstract
Background: A locking compression plate (LCP) of the distal femur is used as an external fixator for lower tibial fractures. However, in clinical practice, the technique lacks a standardized approach and a strong biomechanical basis for its stability. Methods: In this paper, internal tibial LCP fixator (Group IT-44), external tibial LCP fixator (Group ET-44), external distal femoral LCP fixator (Group EF-44, group EF-33, group EF-22), and conventional external fixator (Group CEF-22) frames were used to fix unstable fracture models of the lower tibial segment, and anatomical studies were performed to standardize the operation as well as to assess the biomechanical stability and adjustability of the distal femoral LCP external fixator by biomechanical experiments. Results: It was found that the torsional and flexural stiffnesses of group EF-44 and group EF-33 were higher than those of group IT-44 and group ET-44 (p < 0.05); the flexural stiffness of group EF-22 was similar to that of group IT-44 (p > 0.05); and the compressive stiffness of all three EF groups was higher than that of group ET-44 (p < 0.05). In addition, the flexural and compressive stiffnesses of the three EF groups decreased with the decrease in the number of screws (p < 0.05), while the torsional stiffness of the three groups did not differ significantly between the two adjacent groups (p > 0.05). Group CEF-22 showed the highest stiffnesses, while group ET-44 had the lowest stiffnesses (P < 0.05). Conclusions: The study shows that the distal femoral LCP has good biomechanical stability and adjustability and is superior to the tibial LCP as an external fixator for distal tibial fractures, as long as the technique is used in a standardized manner according to the anatomical studies in this article.Keywords
All Related Versions
This publication has 45 references indexed in Scilit:
- The treatment of complex tibial shaft fractures by the Ilizarov methodThe Journal of Bone and Joint Surgery. British volume, 2012
- Metaphyseal locking compression plate as an external fixator for the distal tibiaInternational Orthopaedics, 2012
- Using External and Internal Locking Plates in a Two-Stage Protocol for Treatment of Segmental Tibial FracturesJournal of Trauma: Injury, Infection & Critical Care, 2011
- LCP external fixation - External application of an internal fixator: two cases and a review of the literatureJournal of Orthopaedic Surgery and Research, 2010
- Locked Plating of Distal Femur Fractures Leads to Inconsistent and Asymmetric Callus FormationJournal of Orthopaedic Trauma, 2010
- Extra-Articular Distal Tibia Fractures: A Mechanical Evaluation of 4 Different Treatment MethodsJournal of Orthopaedic Trauma, 2010
- Biomechanical testing of the locking compression plate: When does the distance between bone and implant significantly reduce construct stability?Injury, 2007
- The Strength of Plate Fixation in Relation to the Number and Spacing of Bone ScrewsJournal of Orthopaedic Trauma, 1996
- Complications Encountered in the Treatment of Pilon FracturesJournal of Orthopaedic Trauma, 1992
- The AO-plate for external fixation in 12 casesActa Orthopaedica, 1991