DWDewei Wang

Dewei Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dewei Wang has a total of 26 co-authors. Here are the top co-authors by number of shared publications:

  • Huan Su

    Department of Bone and Joint Surgery, Bijie Traditional Chinese Medicine Hospital, Bijie, China

    6 shared publications
  • Tianyong Ma

    Second Department of Orthopedics, Fifth Affiliated Hospital of Zunyi Medical University, Zhuhai, China

    5 shared publications
  • Yihong Lu

    Second Department of Orthopedics, Fifth Affiliated Hospital of Zunyi Medical University, Zhuhai, China

    5 shared publications
  • Fang Lei

    Second Department of Orthopedics, Fifth Affiliated Hospital of Zunyi Medical University, Zhuhai, China

    4 shared publications
  • Junping Chen

    Second Department of Orthopedics, Fifth Affiliated Hospital of Zunyi Medical University, Zhuhai, China

    3 shared publications
  • Weiyuan Tan

    Second Department of Orthopedics, Fifth Affiliated Hospital of Zunyi Medical University, Zhuhai, China

    3 shared publications

Latest Publications

  • Open Access

    Effect of Screw Distribution on Stability and Interfragmentary Strain of Lower Tibial Fractures: A Finite Element Analysis

    by Huan Su, Huan Xiao, Jian-Jun Zhou, Fang Lei, Liang Liang, De-Wei Wang

    Objective: The aim of this study was to explore the influence of working length (determined by the screw position) on the stiffness and interfragmentary strain (IFS) of femoral locking compression plate (LCP) external fixators for lower tibial fractures under full weight-bearing conditions, with the goal of providing a reference basis for clinical applications. Methods: Finite element analysis software was used to construct a model of a lower tibial fracture with external femoral LCP fixation. The models were divided into four groups according to the different working lengths (external femoral locking plate fixation 1 [EF1], EF2, EF3, and EF4). Stress distribution clouds, fracture end displacements, stiffness and IFS were tested for each model group at different loads. Results: Compared with those in the EF1 group, the stiffnesses in the EF2, EF3, and EF4 groups decreased by 28%, 31%, and 37%, respectively, under axial compression loading. Compared with those in the EF1 group, the stiffnesses in the EF2, EF3, and EF4 groups decreased by 19%, 33%, and 35%, respectively, under axial torsion loading. Compared with those in the EF1 group, the stiffnesses in the EF2, EF3, and EF4 groups decreased by 32%, 33%, and 35%, respectively, under a three-point bending load. The IFS of the four finite element models increased with the working length of the plate, with EF1 (76%) < EF2 (107%) < EF3 (110%) < EF4 (122%). Finite element analysis revealed that under full weight-bearing conditions, the structural stiffness of the femoral LCP external fixator decreased with increasing working length, leading to an increase in the IFS, which resulted in an IFS that exceeded the ideal range required for secondary healing. Conclusion: For unstable lower tibial fractures, screws in the femoral LCP external fixator should be placed as close to the fracture end as possible to increase stability and promote fracture healing.


  • Open Access

    Efficacy of intramedullary bridge fixation for midshaft clavicle fractures: a retrospective analysis of a novel technique

    by Tianyong Ma, Huan Su, Yihong Lu, Junping Chen, Weiyuan Tan, Fang Lei, Dewei Wang

    Background: The aim of this study was to explore the efficacy of a novel intramedullary fixation technique using the ortho-bridge system (OBS) for midshaft clavicle fractures. Methods: A total of 63 patients were included in this study: 35 underwent plate internal fixation (LP group) and 28 underwent OBS intramedullary fixation (OBS group). Surgical time, intraoperative blood loss, incision length, fracture healing time, removal of the internal fixation agent, visual analog scale (VAS) score for shoulder pain, Constant–Murley shoulder score and complication occurrence were compared between the two groups. Results: Preoperative general data, such as sex, age and fracture type, were not significantly different between the two groups (P > 0.05). However, the OBS group exhibited better outcomes than the LP group exhibited in terms of surgical time, intraoperative blood loss and total incision length (P < 0.05). Additionally, the OBS group exhibited a significantly shorter fracture healing time and internal-fixation removal time than the LP group exhibited (P < 0.05). The VAS scores on postoperative day 1, week 1, month 1 and month 3 were lower in the OBS group than in the LP group (P < 0.05). Furthermore, the Constant–Murley shoulder scores at 1, 3, and 6 months postoperatively were higher in the OBS group than in the LP group (P < 0.05), with no significant difference at 1 year after surgery (P > 0.05). None of the patients in the OBS group experienced scarring of the surgical incision, and 6 patients in the LP group experienced scarring of the surgical incision. Finally, the complication incidence in the OBS group was lower than that in the LP group. Conclusion: For midshaft clavicle fractures, OBS intramedullary fixation is better than locking-plate internal fixation because it led to less trauma, a faster recovery, better efficacy, and better esthetic outcomes and comfort. Therefore, this technique may have potential as a novel treatment for midshaft clavicle fractures. Level of evidence: III, retrospective observational study.


  • Open Access

    Efficacy of Intramedullary Bridge Fixation for Midshaft Clavicle Fractures: A Retrospective Analysis of a Novel Technique

    by Tianyong Ma, Huan Su, Yihong Lu, Junping Chen, Weiyuan Tan, Fang Lei, Dewei Wang

    Objective: This study aimed to explore the efficacy of a novel intramedullary fixation technique using the ortho-bridge system (OBS) in midshaft clavicle fractures. Methods: A total of 63 patients were included in this study, of which 35 were treated with plate internal fixation (LP group) and 28 with OBS intramedullary fixation (OBS group). Surgical time, intraoperative blood loss, incision length, fracture healing time, removal of internal fixation, visual analog scale (VAS) for shoulder pain, Constant Shoulder Score and complication occurrence were compared between the two groups. Results: In preoperative general data, such as sex, age and fracture types were not significantly different between the two groups (P > 0.05). However, the OBSgroup showed better outcomes than the LP group in terms of surgical time, intraoperative blood loss and total incision length (P< 0.05). Additionally, the OBS group exhibited significantly shorter fracture healing time and internal fixation removal time than the LPgroup (P < 0.05). VAS scores at postoperative day 1, week 1, month 1 and month 3 were lower in the OBS group than in the LPgroup (P < 0.05).Furthermore, the OBS group had higher Constant Shoulder Scores at 1, 3, and 6 months than the LPgroup (P < 0.05), with no significant difference at 1 year postoperatively (P > 0.05). There was no scarring in the surgical incision in the OBS group, while 6 cases of scarring in the surgical incision occurred in the LP group. Lastly, complication incidence in the OBS group was lower than that in the LPgroup. Conclusion: The study revealed that compared to locking plate internal fixation for midshaft clavicle fractures, OBS intramedullary fixation presents the advantages of less trauma, faster recovery, better efficacy and better aesthetic outcomes and comfort. Therefore, this technique may have potential clinical application as a novel treatment for midshaft clavicle fractures.

  • Open Access

    Efficacy of Intramedullary Bridge Internal Fixation System for Midshaft Clavicle Fractures: A Novel Technique for Clavicle Treatment

    by Tianyong Ma, Huan Su, Yihong Lu, Junping Chen, Weiyuan Tan, Fang Lei, Dewei Wang

    Objective: The intramedullary nail fixation approach currently used for midshaft clavicle fractures is associated with complications, including nail loosening and displacement, nail end protrusion and soft tissue irritation. In this study, we propose a novel intramedullary fixation technique using the ortho-bridge system (OBS) to improve clinical outcomes and avoid the issues linked with treating midshaft clavicle fractures. Methods: Sixty-three patients with midshaft clavicle fractures were randomly categorized into a control group (n = 35) and an observation group (n = 28). The control group received internal fixation with a locking plate, while the observation group underwent OBS intramedullary fixation. Surgical time, intraoperative blood loss, incision length, fracture healing time, removal of internal fixation, visual analog scale (VAS) for shoulder pain, Constant Shoulder Score and complication occurrence were compared between the two groups. Results: In preoperative general data, such as sex, age and fracture types were not significantly different between the two groups (P > 0.05). However, the observation group showed better outcomes than the control group in terms of surgical time, intraoperative blood loss and total incision length (P< 0.05). Additionally, the observation group exhibited significantly shorter fracture healing time and internal fixation removal time than the control group (P < 0.05). VAS scores at postoperative day 1, week 1, month 1 and month 3 were lower in the observation group than in the control group (P< 0.05).Furthermore, the observation group had higher Constant Shoulder Scores at 1, 3,and 6 months than the control group (P < 0.05), with no significant difference at 1 year postoperatively (P > 0.05). Lastly, complication incidence in the observation group was significantly lower than that in the control group (P < 0.05). Conclusion: The study revealed that compared to locking plate internal fixation for midshaft clavicle fractures, OBS intramedullary fixation offers advantages, including reduced surgical trauma, lesser postoperative pain, faster fracture healing, earlier shoulder joint function recovery and fewer complications. Additionally, this approach provides better aesthetic outcomes and comfort in the surgical area. Therefore, this technique may have potential clinical application as a novel treatment for midshaft clavicle fractures.

  • Open Access

    Can ChatGPT/GPT-4 assist surgeons in confronting patients with Mpox and handling future epidemics?

    by Yongbin He, Haiyang Wu, Yan Chen, Dewei Wang, Weiming Tang, M. Anthony Moody, Guoxin Ni, Shuqin Gu

    An abstract is unavailable. This article is available as a PDF only.


  • Open Access

    Biomechanical study of the stiffness of the femoral locking compression plate of an external fixator for lower tibial fractures

    by Huan Su, Siyang Zhong, Tianyong Ma, Weidong Wu, Yihong Lu, Dewei Wang

    Background: A locking compression plate (LCP) of the distal femur is used as an external fixator for lower tibial fractures. However, in clinical practice, the technique lacks a standardized approach and a strong biomechanical basis for its stability. Methods: In this paper, internal tibial LCP fixator (Group IT-44), external tibial LCP fixator (Group ET-44), external distal femoral LCP fixator (Group EF-44, group EF-33, group EF-22), and conventional external fixator (Group CEF-22) frames were used to fix unstable fracture models of the lower tibial segment, and anatomical studies were performed to standardize the operation as well as to assess the biomechanical stability and adjustability of the distal femoral LCP external fixator by biomechanical experiments. Results: It was found that the torsional and flexural stiffnesses of group EF-44 and group EF-33 were higher than those of group IT-44 and group ET-44 (p < 0.05); the flexural stiffness of group EF-22 was similar to that of group IT-44 (p > 0.05); and the compressive stiffness of all three EF groups was higher than that of group ET-44 (p < 0.05). In addition, the flexural and compressive stiffnesses of the three EF groups decreased with the decrease in the number of screws (p < 0.05), while the torsional stiffness of the three groups did not differ significantly between the two adjacent groups (p > 0.05). Group CEF-22 showed the highest stiffnesses, while group ET-44 had the lowest stiffnesses (P < 0.05). Conclusions: The study shows that the distal femoral LCP has good biomechanical stability and adjustability and is superior to the tibial LCP as an external fixator for distal tibial fractures, as long as the technique is used in a standardized manner according to the anatomical studies in this article.


  • Open Access

    Biomechanical Study of the Stiffness of the Femoral Locking Compression Plate of an External Fixator for Lower Tibial Fractures

    by Huan Su, Siyang Zhong, Tianyong Ma, Weidong Wu, Yihong Lu, Dewei Wang

    Background: A locking compression plate (LCP) of the distal femur is used as an external fixator for lower tibial fractures. However, in clinical practice, the technique lacks a standardized approach and a strong biomechanical basis for its stability. Methods: In this paper, internal tibial LCP fixator (Group IT-44), external tibial LCP fixator (Group ET-44), external distal femoral LCP fixator (Group EF-44, group EF-33, group EF-22), and conventional external fixator frame (Group CEF-22) were used to fix the unstable fracture models of the lower tibial segment, and anatomical studies were performed to standardize the operation as well as to assess the biomechanical stability and adjustability of the distal femoral LCP external fixator by biomechanical experiments. Results: It was found that the torsional and flexural stiffness of the group EF-44 and group EF-33 were better than those of the group IT-44 and group ET-44 (p0.05); and the compressive stiffness of all three EF groups was better than that of the group ET-44 (pConclusions: The study shows that the distal femoral LCP has good biomechanical stability and adjustability, and it is superior to the tibial LCP as an external fixator for distal tibial fractures, as long as the technique is used in a standardized manner according to the anatomical studies in this article.

  • [Clinical application effects of two longitudes three transverses method in perforator location of thoracodorsal artery perforator flap and deep wound repair].

    by G T Huang, Z R Wei, L Huang, S J Li, W Chen, C L Yang, K Y Nie, C L Deng, D L Wang

    Objective: To explore the clinical application value of two longitudes three transverses method in the location of the perforator of thoracodorsal artery perforator and deep wound repair. Methods: The retrospectively observational study was conducted. From December 2018 to June 2020, 17 patients with deep wounds who were admitted to the Affiliated Hospital of Zunyi Medical University met the inclusion criteria and were included in this study, including 7 males and 10 females, aged 12 to 72 years. The wound areas of patients after debridement were 7 cm×3 cm to 11 cm×7 cm. Two longitudinal lines were located through the midpoint of the armpit, the posterior superior iliac spine, and the protruding point of the sacroiliac joint, and three transverse lines were located 5, 10, and 15 cm below the midpoint of the armpit between the two longitudinal lines, i.e. two longitudes three transverses method, resulting in two trapezoidal areas. And then the thoracodorsal artery perforators in two trapezoidal areas were explored by the portable Doppler blood flow detector. On this account, a single or lobulated free thoracodorsal artery perforator flap or flap that carrying partial latissimus dorsi muscle, with an area of 7 cm×4 cm to 12 cm×8 cm was designed and harvested to repair the wound. The donor sites were all closed by suturing directly. The number and location of thoracodorsal artery perforators, and the distance from the position where the first perforator (the perforator closest to the axillary apex) exits the muscle to the lateral border of the latissimus dorsi in preoperative localization and intraoperative exploration, the diameter of thoracodorsal artery perforator measured during operation, and the flap types were recorded. The survivals of flaps and appearances of donor sites were followed up. Results: The number and location of thoracodorsal artery perforators located before operation in each patient were consistent with the results of intraoperative exploration. A total of 42 perforators were found in two trapezoidal areas, with 2 or 3 perforators each patient. The perforators were all located in two trapezoid areas, and a stable perforator (the first perforator) was located and detected in the first trapezoidal area. There were averagely 1.47 perforators in the second trapezoidal area. The position where the first perforator exits the muscle was 2.1-3.1 cm away from the lateral border of the latissimus dorsi. The diameters of thoracodorsal artery perforators were 0.4-0.6 mm. In this group, 12 cases were repaired with single thoracodorsal artery perforator flap, 3 cases with lobulated thoracodorsal artery perforator flap, and 2 cases with thoracodorsal artery perforator flap carrying partial latissimus dorsi muscle. The patients were followed up for 6 to 16 months. All the 17 flaps survived with good elasticity, blood circulation, and soft texture. Only linear scar was left in the donor area. Conclusions: The two longitudes three transverses method is helpful to locate the perforator of thoracodorsal artery perforator flap. The method is simple and reliable. The thoracodorsal artery perforator flap designed and harvested based on this method has good clinical effects in repairing deep wound, with minimal donor site damage.