Comparative Study of Unbonded Carbon Fiber and Steel Strands in Posttensioned Pier Caps
- 1 February 2016
- journal article
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 20 (1)
Abstract
Carbon fiber strands offer a viable alternative to corrosion-prone steel strands in posttensioning applications. This study focused on a side-by-side comparison of two types of carbon fiber strands with different elastic moduli against steel strands in a 5½∶1 scaled model of a typical interior hammerhead pier of the San Antonio Downtown Y project with two identical cantilever overhangs. Two different strand arrangements were used for posttensioning, with eight and six strands, respectively representing an overdesign and a slight underdesign relative to the factored demand. The model was tested under service and factored flexure and shear loads. The study confirmed the feasibility of using carbon fiber strands in unbonded posttensioning of pier caps. Given the strength-based design of the pier cap, the elastic moduli of different carbon fiber strands did not seem to have affected the serviceability performance with respect to either cracking or deflection. Considering both serviceability and overlo...Keywords
This publication has 4 references indexed in Scilit:
- Flexural behavior of side-by-side box-beam bridges: A comparative studyPCI Journal, 2011
- Flexural behavior of precast concrete box beams posttensioned with unbonded, carbon-fibercomposite cablesPCI Journal, 2008
- Experimental Study and Analysis of a Full-Scale CFRP/CFCC Double-Tee Bridge BeamPCI Journal, 2003
- Design-Construction of Bridge Street Bridge — First CFRP Bridge in the United StatesPCI Journal, 2002