Comparative study between a single unit system and a two-unit cold standby system with varying demand
Open Access
- 19 November 2015
- journal article
- research article
- Published by Springer Nature in SpringerPlus
- Vol. 4 (1) , 1-17
Abstract
The concerned paper illustrates the comparison of two stochastic models of a cable manufacturing plant with varying demand. Here, it shows the comparison between a single unit system (Model 1) and a two-unit cold standby system (Model 2). In Model 1, the system is either in working state on some demand or put to shut down mode on no demand. In Model 2, at initial stage, one of the units is operative while the other is kept as cold standby. At times when the operative unit stops working due to some breakdown/failure, the standby unit instantaneously becomes operative while the repairman repairs the failed unit. In this working model, only one unit remains operative at a time. However, there may be a state when both the units fail. The comparison of systems is done by means of MTSF (mean time to system failure), steady state availability and profit function using Laplace transforms and software package Code-Blocks 13.12. Different graphs have been plotted to discover which model is superior to the other model under the given conditions. The system is analysed by making use of semi-Markov processes and regenerative point technique.Keywords
This publication has 13 references indexed in Scilit:
- Stochastic Analysis of a Two-Unit Cold Standby System Wherein Both Units May Become Operative Depending upon the DemandJournal of Quality and Reliability Engineering, 2014
- Modeling of HIV/AIDS dynamic evolution using non-homogeneous semi-markov processSpringerPlus, 2014
- Reliability and Availability Analysis of a Single Unit System with Varying DemandMATHEMATICAL JOURNAL OF INTERDISCIPLINARY SCIENCES, 2013
- COST-BENEFIT ANALYSIS OF A SINGLE UNIT SYSTEM WITH SCHEDULED MAINTENANCE AND VARIATION IN DEMANDJournal of Mathematics and Statistics, 2013
- Comparative analysis of availability for a redundant repairable systemApplied Mathematics and Computation, 2007
- A STUDY ON A TWO UNIT STANDBY SYSTEM WITH ERLANGIAN REPAIR TIMEAsia-Pacific Journal of Operational Research, 2004
- Reliability prediction of imperfect switching systems subject to multiple stressesMicroelectronics Reliability, 1997
- Two models for two-dissimilar-unit standby redundant system with three types of repair facilities and perfect or imperfect switchMicroelectronics Reliability, 1994
- The reliability of a dynamic warm standby redundant system of n components with imperfect switchingMicroelectronics Reliability, 1992
- Analysis of a two-unit system with partial failures and three types of repairsReliability Engineering & System Safety, 1991