Abstract
Introduction: This study quantified the number of intraoperative microemboli in patients undergoing aortic arch surgery using selective cerebral perfusion (SCP) in comparison with those in patients undergoing ascending aortic replacement without circulatory arrest and SCP. Methods: A transcranial Doppler monitoring of the medial cerebral artery was performed in 15 patients undergoing proximal arch replacement with SCP (SCP group) and 15 patients undergoing replacement of the ascending aorta (Control group). Results: There was no significant difference in the high-intensity transient signals count between the SCP group and the Control group at any phase. In the SCP group, 4.8% of microemboli occurred during crossclamping, and only 0.6% occurred during SCP. In the Control group, 4.6% occurred during crossclamping. Most microemboli occurred after declamping in both groups; 92.2% in the SCP group and 92.1% in the Control group. Conclusion: The present study demonstrated that outbreak frequency of microemboli during SCP was very low, and thus implies that the risk of embolic event which may be caused by SCP is very low.