Graphical Comparison of Critically Damped Versus Overdamped Free Vibration of Single Degree of Freedom Structure
Open Access
- 1 January 2019
- journal article
- Published by Southwest Jiaotong University in Journal of Southwest Jiaotong University
- Vol. 54 (5)
Abstract
In most vibration structural problems, the value of damping is less than unity. Such a small amount of damping may increase near or exceed unity under certain special circumstances. Critically damped and overdamped solutions are completed until the final expressions are generated and an indication provided by MATLAB as to how these expressions depend on viscous damping ratios, natural frequencies, and initial conditions. The developed equations of various damping systems, which are commonly employed in vibration analyses, are compared, with several important observations are noted. Natural frequency is of primary importance when controlling the settling time of critically damped and overdamped vibration responses. Initial conditions are also considered main factors that affect critically damped and overdamped vibration peak responses. Damping plays a crucial role in the peak response of an overdamped system. A direct relationship between the damping ratio and the peak response is observed, whereas an inverse relationship exists between the damping ratio and the settling time. Therefore, critically damped and overdamped systems exhibit an identical response in the large scale perspective, whereby they first rise and then fall. In the zoomed scale, the peak response of the overdamped system is lower than that of the critically damped system, and the latter falls faster than the former. No cyclic response is observed, and the vibration statement is abnormally used for both critically damped and overdamped systems.Keywords
This publication has 7 references indexed in Scilit:
- Numerical Solutions for Nonlinear High Damping Rubber Bearing Isolators: Newmark’s Method with Netwon-Raphson Iteration RevisitedJournal of Theoretical and Applied Mechanics, 2018
- Wind Effects and Dynamics Characteristics of Base-Isolated Building based on Full-scale measurement during TyphoonsProcedia Engineering, 2017
- Design of Buildings with Seismic Isolation Using Linear Quadratic AlgorithmProcedia Engineering, 2017
- Utilizing Base-isolation Systems to Increase Earthquake Resiliency of Healthcare and School BuildingsProcedia Economics and Finance, 2014
- 2D physics-based deformable objects using fast free vibration modal analysis2004
- Experiments on a base-isolated building in Santiago, ChileEngineering Structures, 1998
- Dynamic response of structures with uncertain dampingEngineering Structures, 1990