3-D imaging using row-column-addressed 2-D arrays with a diverging lens: Phantom study
- 1 September 2017
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Abstract
A double-curved diverging lens over a flat row-column-addressed (RCA) 2-D array can extend its inherent rectilinear 3-D imaging field-of-view (FOV) to a curvilinear volume region, which is necessary for applications such as abdominal and cardiac imaging. A concave lens with radius of 12.7 mm was manufactured using RTV664 silicone. The diverging properties of the lens were evaluated based on measurements on several phantoms. The measured 6 dB FOV in contact with a material similar to human soft tissue was less than 15% different from the theoretical predictions, i.e., a curvilinear FOV of 32°×32°. A synthetic aperture imaging sequence with single element transmissions was designed for imaging down to 14 cm at a volume rate of 88 Hz. The performance was evaluated in terms of signal-to-noise ratio (SNR), FOV, and full-width-at-half-maximum (FWHM). The penetration depth in a tissue mimicking phantom with 0.5 dB/(cm MHz) attenuation was 13 cm. The results of this study confirm that the proposed lens approach is an effective method for increasing the FOV, when imaging with RCA 2-D arrays.Keywords
This publication has 12 references indexed in Scilit:
- Fabrication of a Curved Row–Column Addressed Capacitive Micromachined Ultrasonic Transducer ArrayJournal of Microelectromechanical Systems, 2016
- Safety Assessment of Advanced Imaging Sequences I: MeasurementsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2015
- Safety Assessment of Advanced Imaging Sequences II: SimulationsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2015
- 3-D imaging using row-column-addressed arrays with integrated apodization - part i: apodization design and line element beamformingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2015
- 3-D imaging using row–column-addressed arrays with integrated apodization— part ii: transducer fabrication and experimental resultsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2015
- Crossed-array transducer for real-time 3D imaging2014
- Top orthogonal to bottom electrode (TOBE) 2-D CMUT arrays for 3-D photoacoustic imagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2014
- SARUS: A synthetic aperture real-time ultrasound systemIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2013
- Real-time volume imaging using a crossed electrode arrayIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2009
- Field Guide to Geometrical Optics2004