Direct Implementation of MSn Using Frequency Scanning Collision Induced Dissociation in a Digital Ion Trap Mass Spectrometer
- 23 December 2024
- journal article
- research article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 36 (2) , 309-317
Abstract
Tandem mass spectrometry (MSn) is one of the most effective methods to obtain the structures of organic molecules, enabling the observation of multigenerational ion fragments. Collision-induced dissociation (CID) is currently the most mature technique for mass spectrometry analysis. Ion trap mass spectrometry (ITMS) is favored for on-site detection field, due to its ability of MSn analysis with a single trap and its small size. However, conventional MSn analysis in ITMS requires repeated isolation and excitation processes multiple times, causing high complexity of the entire scanning process. Additionally, the fragment ion detection in ITMS is limited by low-mass cutoff (LMCO) and the weak fragmentation yield. In this study, a method named reverse scanning-collision induced dissociation (RS-CID) is proposed, which involves increasing RF and AC frequencies while maintaining RF voltage constant during the CID process. Twelve representative illegal drugs were analyzed adopting this method, enhancing the intensities of low-mass fragment ions compared to conventional dissociation method. Moreover, experimental results with ketamine and methamphetamine show that RS-CID effectively reduces the LMCO effect and slightly improves CID efficiency. It also enables direct acquisition of their multigeneration fragment ions spectra in a single sequence of ion injection, cooling, isolation, RS-CID, cooling, mass scanning and empty. The experiments to distinguish between the isomers ab-4en-pinaca and adb-3en-butinaca as well as the isomeric compounds 5f-cumyl-pegaclone and cumyl-pipetinaca were also successful by this method. In summary, RS-CID enables MSn analysis in a single sequence and improves the low-mass fragment ions intensity. It can simplify workflows, achieve faster analysis and provide more valuable mass spectral information.Keywords
Funding Information
- National Key Research and Development Program of China (2022YFC3300900)
- National Natural Science Foundation of China (21904091)
- National High Level Hospital Clinical Research Funding (BJ-2022-095)
This publication has 45 references indexed in Scilit:
- FIELDABLE MASS SPECTROMETRY FOR FORENSIC SCIENCE, HOMELAND SECURITY, AND DEFENSE APPLICATIONSMass Spectrometry Reviews, 2020
- Mass spectrometry and planetary exploration: A brief review and future projectionJournal of Mass Spectrometry, 2019
- Comprehensive investigation on synthetic cannabinoids: Metabolic behavior and potency testing, using 5F‐APP‐PICA and AMB‐FUBINACA as model compoundsDrug Testing and Analysis, 2019
- Comparison of the activation time effects and the internal energy distributions for the CID, PQD and HCD excitation modesJournal of Mass Spectrometry, 2014
- Identification of carbonylated proteins from enriched rat skeletal muscle mitochondria using affinity chromatography‐stable isotope labeling and tandem mass spectrometryProteomics, 2007
- Energetics and efficiencies of collision‐induced dissociation achieved during the mass acquisition scan in a quadrupole ion trapRapid Communications in Mass Spectrometry, 2005
- A digital ion trap mass spectrometer coupled with atmospheric pressure ion sourcesJournal of Mass Spectrometry, 2004
- Linear ion traps in mass spectrometryMass Spectrometry Reviews, 2004
- Solvation of acylium fragment ions in electrospray ionization quadrupole ion trap and Fourier transform ion cyclotron resonance mass spectrometryJournal of Mass Spectrometry, 2001
- Tandem mass spectrometry: dissociation of ions by collisional activationJournal of Mass Spectrometry, 2000