YZYunjing Zhang

Yunjing Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yunjing Zhang has a total of 63 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Spurious-Mode Suppression and Efficient Design of LiTaO3 XBAR Filters Using a FEM–COM–ABC Framework

    by Jiabao Tang, Zifan Miao, Yunjing Zhang, Xingli He

    Laterally excited bulk acoustic wave resonators (XBARs) on lithium tantalate (LiTaO3, LT) are promising for wideband radio-frequency filters, but spurious modes and costly full-wave optimization hinder development. Limited coupling-bandwidth flexibility in commercial LT cuts motivates exploring non-standard orientations. We present a numerical framework integrating the finite-element method (FEM), coupling-of-modes (COM) theory, and artificial bee colony (ABC) optimization, emphasizing non-commercial 120° YX-LT. Hierarchical FEM screens orientation and periodic-cell response and then resolves finite aperture, busbars, and membrane boundaries. Compared with rectangular boundaries, an irregular pentagonal membrane disrupts coherent edge reflections, suppressing in-band spurious glitches and slightly enhancing effective coupling. A thickness-dependent COM model calibrated across a broad SiO2 loading range reproduces FEM resonance and antiresonance frequencies within 1 MHz. The surrogate enables mixed-variable ABC optimization of finger-pair number, normalized aperture, and stage-specific wavelengths. Five-stage ladder filters are synthesized and verified by direct FEM reconstruction. Stage-dependent wavelengths improve simulated passband transmission and reduce ripple versus a common-wavelength baseline; COM–FEM stopband discrepancies indicate the need for full-wave verification. After calibration, ABC core search takes approximately 2.9 h without repeated full-wave solutions. This transferable framework provides a cost-effective pathway from full-wave physics to circuit-level filter synthesis on thin-film piezoelectric platforms.

  • Air-Based Porous Array Dielectric Barrier Discharge Ionization Source for Explosive Trace Detection

    by Tianyi Zhao, Jie Ren, Zihang Jia, Lingfeng Li, Yunjing Zhang, Xingli He, Peng Li

    A novel atmospheric pressure ionization source for explosive trace detection was proposed and validated, which balances practical application requirements with detection performance. The ionization source adopted porous array dielectric barrier discharge (DBD) technology on a printed circuit board (PCB) with air as the discharge gas. Larger-area discharge improved ion generation efficiency, with the ion current exceeding 300 nA. Countercurrent gas flow effectively removed interference of ozone and reactive nitrogen oxides generated by dielectric barrier discharge. Meanwhile, pulsed discharge was employed to further reduce interference, as well as decrease power consumption and extend the lifetime of the ionization source. Combined with a homemade miniature digital linear ion trap mass spectrometer, the performance was evaluated for various typical nitro explosives (TNT, 2,4-DNT, NG, RDX, PETN, and HMX), demonstrating good linear response over a concentration range exceeding 2 orders of magnitude. Detection results of real samples and simulated mixtures further verify the applicability of this method. This DBD structure design offers advantages including compact size, soft ionization, low detection limit (e.g., 0.0025 ng for 2,4-DNT), no need for additional reagents or consumable gases, and simple operation. This work provides a feasible ionization source design for the next generation of mass-spectrometry-based explosive trace detection technology.

  • The New Scanning Mode in Digital Linear Ion Trap Mass Spectrometry for the Detection of New Psychoactive Substances in E-Cigarette Oils

    by Sen Tian, Jiecong Lu, Yunjing Zhang, Xingli He, Lingfeng Li, Peng Li

    The abuse of new psychoactive substances (NPS) has become a growing global concern, and their illegal addition to commercial e-cigarette oils poses severe threats to human health and potentially results in fatalities. Regulatory control of NPS remains challenging owing to their rapid structural evolution. Meanwhile, laboratory-based detection methods are constrained by long turnaround times, highlighting the necessity of on-site rapid detection for timely interception and response. Mass spectrometry offers superior sensitivity and specificity for trace NPS detection, and a portable mass spectrometer has shown potential for on-site applications. Precursor ion and neutral loss scanning, which enable class-selective detection of unknown analogues via specific functional groups, have not yet been applied to the on-site rapid screening of NPS in e-cigarette oils. In this study, we implemented these two scanning modes in a portable digital linear ion trap mass spectrometer (DLIT-MS) for the first time. Compared with the analogue radio frequency (RF)-driven ion trap mass spectrometer, at the same RF amplitude and ion q-value, DLIT-MS has a deeper pseudopotential well, enabling lower q-values for precursor ions. Additionally, it uses low-voltage rectangular waveforms synthesized by digital circuits, enabling precise frequency control and exceptional flexibility for multimode analysis, and thus is suitable for on-site rapid detection of NPS. Here, four sets of drug standard samples were analyzed using the portable DLIT-MS to characterize the performance of the proposed method. Subsequently, further experiments were conducted with standard solutions of two major classes of NPS: synthetic cannabinoids and fentanyl, along with their analogues. Finally, the method was applied to the detection of illegally adulterated NPS, including etomidate and its analogues, as well as synthetic cannabinoids, in commercially available e-cigarette oil samples. Experimental results demonstrated that precursor ion and neutral loss scanning, when performed on portable DLIT-MS, can effectively identify target compounds and their structurally related derivatives. This finding confirms the application potential of these two scanning modes in portable DLIT-MS for the on-site rapid detection of illegally added NPS in e-cigarette oils.


  • Development of Tandem Ion Mobility Spectrometry Based on Heat-Induced Dissociation and Its Application in Explosives Detection

    by Tianxin Xian, Tianyi Zhao, Sen Tian, Yunjing Zhang, Xingli He, Peng Li, Lingfeng Li

    Ion mobility spectrometry (IMS) serves as a crucial analytical technique and has been extensively applied to the analysis of hazardous explosives. However, the detection of ions with the same or similar mobility remains a significant challenge for IMS. Just as tandem mass spectrometry plays a crucial role in analysis, the development of tandem ion mobility spectrometry has also greatly enhanced the qualitative capabilities; ion dissociation technology is one of the key components. This study creatively introduces a heat-induced dissociation (HID) technique and develops a HID module for ion dissociation. Primarily, the HID module was integrated into a homemade ion trap mass spectrometer to validate the feasibility of the HID technology. Subsequently, the thermal field distribution of the HID module was simulated, thereby highlighting the significance of the temperature in the dissociation process. Finally, a tandem drift tube ion mobility spectrometry (DTIMS) detection system incorporating a HID module was established. Five representative explosive samples were selected to validate the feasibility of the tandem DTIMS. Both atmospheric pressure dissociation mass spectra and mobility spectra were obtained, and their dissociation products were analyzed through comparison with collision-induced dissociation (CID). The results demonstrate that incorporating HID technology into the tandem DTIMS system enables ion dissociation and the acquisition of atmospheric pressure second-order ion mobility spectra. The combination of fragment peak information enhances the qualitative capabilities of ion mobility spectrometry. This advancement is anticipated to reduce the probability of false positives in future applications, thereby improving the accuracy and reliability of the system. This study provides critical technical support for explosive detection in the field of public safety.


  • Machine Learning-Enabled Liquid Recognition Based on Multiple Microwave Complementary Split-Ring Resonators

    by Yi Fan Zhou, Jing Lei Yong, Peng Li, Yun Jing Zhang

    In this study, we propose a microwave sensor, which is composed of triple complementary split-ring resonators (CSRRs), for liquid recognition. Compared to a single CSRR, the sensor exhibits more resonant features, enabling high identification accuracy. The sensor aims to recognize liquids in common drink bottles without damaging the contents, offering significant potential for safety inspection. However, challenges arise due to error factors such as placement, dimensions of the bottles, and, in particular, uneven surfaces. To address these issues, we employ a feedforward neural network (FNN) to enhance accuracy. A total of 26 different liquid samples are tested, and for each sample, 160 measured S21 datasets are used for training the FNN parameters, while 40 datasets serve to validate the model. When the bottles are positioned upright, the trained model achieves a stable identification accuracy of 97% after 2000 epochs. To improve the performance which is limited by the air frustum groove between the bottle and the sensing region, we propose placing the bottles on the sensor with the cap facing downward. This configuration minimizes the air gap, as the relatively flat cap fits closely with the sensing area. With this adjustment, the trained model achieves 100% accuracy after 800 epochs, demonstrating improved accuracy and efficiency. The proposed identification method and sensor also have potential applications in chemical, biological, and medicinal liquid analysis.


  • Multifrequency Microwave Liquid Identification Sensor Based on Interdigital Split Ring Resonators

    by Jing Lei Yong, Peng Li, Xing Li He, Mei Song Tong, Le Tian Guo, Yun Jing Zhang

    In this paper, a novel multifrequency microwave sensor comprising four interdigital split ring resonators (SRRs) coupled to a microstrip feed line is proposed for measuring types and volume fractions of liquids. The interdigital SRR is based on a traditional SRR with its split replaced by an interdigital capacitor (IDC) structure. The IDC in the SRR, serving as the sensing region, has strong electric fields, highly responsive to variations in the dielectric properties of the sample. To mitigate the influence of the sample on the microstrip feed line, a ground plane is inserted between the feed line and sensing region. Different samples exhibit distinct resonant frequencies and transmission magnitude of the sensor, which are used to invert their complex permittivity through a mathematical relationship model. Subsequently, liquid types and concentrations can be identified based on a pre-established knowledge database. Significantly, the four-resonance frequency measurement enables to determine the dielectric dispersion of the liquids over the 2–6 GHz range, enhancing identification accuracy through the nearest neighbor search principle. Experiments conducted with various liquid types and ethanol solutions of varying concentrations demonstrate the superior identification capability of the sensor. The sensor’s compact size, simple structure, and high identification accuracy highlight its potential for on-site, real-time, non-invasive detection applications.


  • Direct Implementation of MSn Using Frequency Scanning Collision Induced Dissociation in a Digital Ion Trap Mass Spectrometer

    by Jie Ren, Pingping Chen, Yunjing Zhang, Xingli He, Lingfeng Li, Peng Li

    Tandem mass spectrometry (MSn) is one of the most effective methods to obtain the structures of organic molecules, enabling the observation of multigenerational ion fragments. Collision-induced dissociation (CID) is currently the most mature technique for mass spectrometry analysis. Ion trap mass spectrometry (ITMS) is favored for on-site detection field, due to its ability of MSn analysis with a single trap and its small size. However, conventional MSn analysis in ITMS requires repeated isolation and excitation processes multiple times, causing high complexity of the entire scanning process. Additionally, the fragment ion detection in ITMS is limited by low-mass cutoff (LMCO) and the weak fragmentation yield. In this study, a method named reverse scanning-collision induced dissociation (RS-CID) is proposed, which involves increasing RF and AC frequencies while maintaining RF voltage constant during the CID process. Twelve representative illegal drugs were analyzed adopting this method, enhancing the intensities of low-mass fragment ions compared to conventional dissociation method. Moreover, experimental results with ketamine and methamphetamine show that RS-CID effectively reduces the LMCO effect and slightly improves CID efficiency. It also enables direct acquisition of their multigeneration fragment ions spectra in a single sequence of ion injection, cooling, isolation, RS-CID, cooling, mass scanning and empty. The experiments to distinguish between the isomers ab-4en-pinaca and adb-3en-butinaca as well as the isomeric compounds 5f-cumyl-pegaclone and cumyl-pipetinaca were also successful by this method. In summary, RS-CID enables MSn analysis in a single sequence and improves the low-mass fragment ions intensity. It can simplify workflows, achieve faster analysis and provide more valuable mass spectral information.


  • Development of an Ion Mobility Spectrometer Based on a Pulsed Photoelectric Effect Ionization Source

    by Tianyun Wu, Yan Wang, Wenhui Li, Lingfeng Li, Xiaozhi Wang, Peng Li, Yunjing Zhang, Xingli He

    Ion mobility spectrometry (IMS) is a compact and sensitive trace gas analysis instrument that ionizes the sample into ions for detection. Typically, an ion gate is used to cut the continuous ion beam into ion packets for separation and detection. However, commonly used ion gates suffer from complex structures or low ion transmission rates, making the gateless IMS a viable alternative. In this study, an IMS based on a pulsed photoelectric effect ionization source was designed. The photoelectrons were generated by irradiating a photoelectric material with a back-illuminated pulsed xenon lamp. This allows for low-energy photoelectron generation and the production of simple reactant ions (O2-(H2O)n) and thus negative product ions. The photoelectron current generated by this ionization source was analyzed, which can reach an intensity of a few microamperes and can be converted into an ion signal exceeding 10 nA. The introduction of the pulsed photoelectric effect ionization source makes it possible to generate separate ion packets and complete ion injection when a constant electric field is maintained in the ionization region. And with an assisted pulsed electric field in the ionization region, the resolving power of the system can be effectively improved to 1.85 times that of the constant electric field. The IMS developed in this study was used for the detection of common volatile hazardous chemicals, yielding effective results. The detection limit for phenol was below 1 ppb, and the dynamic response range exceeded 1 order of magnitude, which implies the potential applications of this IMS to detect substances with high electron affinity, such as explosives detection in public safety.


  • A Reflection–Transmission Multifunctional Polarization Conversion Metasurface

    by Heng Yang, Yuan He, Mei Song Tong, Le Tian Guo, Peng Li, Yun Jing Zhang

    In this paper, a multifunctional polarization conversion metasurface (MPCM) has been proposed that can switch between seven different transmissive and reflective polarization conversion modes. The basic unit cell consists of three layers of split square rings (SSR) separated by two substrates, and a PIN diode is embedded in the top SSR to dynamically control asymmetric transmission and reflection responses. The layer-by-layer design guideline is provided with the polarization conversion mechanism illustrated. A prototype made up of 20 × 20 units was fabricated and measured. The measurement and simulation results demonstrate the versatile polarization conversions including co-polarization reflection, cross-polarization transmission, and circular polarization reflection and transmission, depending on the incident x - and y -polarized waves forward and backward. Significantly, the performance of the MPCM keeps excellent in a large oblique angle range of 50°. The MPCM synthesized from the single SSR layers provides an idea for general transmissive and reflective metasurface design, which is expected to be applied in the fields of radar and wireless communications.