Abstract
In this work, we present an evaluation methodology to determine the SET sensitivity through a heavy ion simulated fault injection technique on a LUT4 of the 7nm FinFET AMD Xilinx Versal FPGA. An individual evaluation of the different blocks that make up a LUT4 will be performed to determine the most sensitive cases. Different SET metrics, such as pulse width distribution and cross-section, will be demonstrated. In addition, an SEU evaluation of a DFF will be performed by varying its operating frequency and supply voltage. This is intended to illustrate a best- and worst-case scenario where the SETs generated by the LUT can be captured by the DFF.
Funding Information
  • Research and Development Project "R&T SEE Versal" funded by CNES

This publication has 22 references indexed in Scilit: