JBJérôme Boch

Jérôme Boch

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jérôme Boch has a total of 167 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Correction to: Kosmiko: from CMOS imaging sensors to pixel-calibrated particle instruments

    by Frédéric Wrobel, Juliette Wrobel, Tadec Maraine, Jérôme Boch, Clément Risso, Luigi Dilillo, Frédéric Saigné

  • Open Access

    Indoor UAV for Nuclear Investigation: Experimental Qualification and Field Feedback

    by Jérémy Seyssaud, Marie Cuozzo, Julien Favrichon, Benjamin Catania, Eric Cantrel, Tadec Marraine, Jérôme Boch

    Indoor Unmanned Aerial Vehicles (UAVs) have recently gained interest for inspection and investigation tasks in hazardous environments. In the nuclear field, indoor UAVs offer promising capabilities to reduce workers' exposure to ionizing radiation while accessing confined or elevated areas. However, their actual operational performance and limitations in nuclear facilities remain poorly documented in the peer‐reviewed literature. This field report documents operational experience from the deployment of an indoor UAV for nuclear investigation at CEA Marcoule (G2/G3 reactor buildings). A four‐level qualification workflow—laboratory functional tests, representative‐site trials, radiological characterization, and active‐facility campaigns—is described to support reproducible field deployment planning rather than to claim methodological novelty. Over approximately 100 flights, the platform inspected 2500 m 2 of cladding in 6 half‐days (45 flights), identified 26 points of interest, and achieved photogrammetry accuracy error of about 1% on dimensional references; source‐search trials located a 137 Cs test source in all four blind tests within two flights on average. The report concludes that indoor UAVs are operationally relevant for rapid visual investigation and qualitative radiological indication in moderate‐dose, low‐dust environments, but are unsuitable as universal investigation tools: battery life is 10 min (reduced by 10%–15% with the dose‐rate payload), dust resuspension can abort missions, transmission fails behind thick shielding, and commercial electronics require conservative cumulative‐dose management. Indoor UAVs should be positioned as complementary to ground robots (RICA, Vega) and wired inspection means, selected according to accessibility, dose, contamination, and acceptable equipment loss.


  • Kosmiko: from CMOS imaging sensors to pixel-calibrated particle instruments

    by Frédéric Wrobel, Juliette Wrobel, Tadec Maraine, Jérôme Boch, Clément Risso, Luigi Dilillo, Frédéric Saigné

  • Open Access

    Kosmiko: From CMOS Imaging Sensors to Pixel-Calibrated Particle Instruments

    by Frédéric Wrobel, Juliette Wrobel, Tadec Maraine, Jérôme Boch, Clément Risso, Luigi Dilillo, Frédéric Saigné

    We present a low-cost, reproducible methodology for detecting ionizing-event candidates in the natural radiation environment by using CMOS active-pixel sensors operated in darkness. The detector platform, called Kosmiko, is based on a Raspberry Pi 5 that controls simultaneously two Sony IMX477 camera modules in raw acquisition mode. Each run consists of a calibration step followed by continuous image acquisition. Candidate events are identified online by comparing each pixel intensity to its intrinsic threshold derived from calibration stage. Pixels that have intensities above their threshold are stored, whereas the others are discarded, which strongly reduces the data volume and enables long-duration acquisitions. The method includes the identification and filtering of hot, noisy and recurrent pixels, together with camera-health indicators based on dark-level statistics, noise distributions and percentiles. Offline analysis then provides event-rate observables, including frame-of-interest rate, cluster rate, intensity distributions, track-like topology indicators and saturated-pixel occurrence. The goal is not to identify individual particle species, but to provide a documented and deployable methodology for comparing ionizing-event rates under different conditions in the natural radiation environment. The complete hardware, software workflow and data products are described to ease reproducibility and future network deployment. Observations about components of the camera and about the local environment are also discussed.

  • Open Access

    Analysis of In-System Performance of Point-of-Load Power Converters During System-Level Irradiation

    by Ivan Slipukhin, Ruben Garcia Alia, Frederic Saigne, Jerome Boch, Luigi Dilillo, Daniel Prelipcean, Matteo Cecchetto, Carlo Cazzaniga, Maria Kastriotou, Salvatore Fiore, et al.

  • X-Ray Impact on Generation-Recombination Low-Frequency Noise Components for Advanced Si/SiGe:C HBTs

    by B. Sagnes, M. Bouhouche, O. Occello, A. Hoffmann, J. Boch, T. Maraine, F. Pascal, S. Haendler, P. Chevalier, D. Gloria, et al.

    This study presents an investigation of X-ray dose impact on Low-Frequency Noise Generation-Recombination components for NPN Si/SiGe:C heterojunction bipolar transistors (HBTs) developed in two BiCMOS technologies. Generation-Recombination (G-R) components are examined in detail both before and after irradiation. Compact modeling for these excess noise components is established after X-ray exposure. They are studied over the irradiation process as a function of current biases and geometrical parameters to locate the noise sources. A thermal annealing process at two temperatures, 100 ∘ C and 130 ∘ C, is accomplished to investigate any possible healing effects on Low-Frequency Noise spectra.


  • Single Event Transient Evaluation of 7nm FinFET LUT4 Representative of Versal

    by A. Urena-Acuna, L. Artola, G. Hubert, S. Achaq, V. Pouget, J. Boch, F. Manni

    In this work, we present an evaluation methodology to determine the SET sensitivity through a heavy ion simulated fault injection technique on a LUT4 of the 7nm FinFET AMD Xilinx Versal FPGA. An individual evaluation of the different blocks that make up a LUT4 will be performed to determine the most sensitive cases. Different SET metrics, such as pulse width distribution and cross-section, will be demonstrated. In addition, an SEU evaluation of a DFF will be performed by varying its operating frequency and supply voltage. This is intended to illustrate a best- and worst-case scenario where the SETs generated by the LUT can be captured by the DFF.

  • Study of TID Response of a Low Cost Motor Board with a System-Level Testing Approach

    by Guillaume Carpentier, Jérôme Boch, Frédéric Saigné, Julien Favrichon, Eric Cantrel, Jean-Roch Vaillé, Tadec Maraine, Frédéric Wrobel, Luigi Dilillo

    The increasing use of COTS components in radiation environments, such as New Space missions and nuclear Decontamination and Decommissioning activities, raises new questions about system-level testing methodologies. In this work, the Total Ionizing Dose response of a motor board, designed as a model platform, is investigated to develop and compare system-level and component-level test approaches. The study relies on a modular board architecture and on the addition of dedicated monitoring parameters to enhance the level of board observability during irradiation. Component-level characterizations are conducted in parallel with system-level tests to identify the origins of degradation mechanisms and to evaluate their impact on overall system behavior. Moreover, a comparison is conducted between board-level irradiations performed with a filtered high energy X-ray generator and a Cobalt-60 gamma source. The results show that the use of combined Aluminum and Lead filtering with the high energy X-ray generator reproduces the degradation observed under Cobalt-60 more accurately than using an Aluminum filter alone, at both the component and board levels. Overall, the study highlights the benefits and limitations of system-level TID testing and demonstrates the relevance of combining system-level and component-level approaches when evaluating COTS-based electronic systems for radiation environments.


  • Characterization and Radiation Testing of an Embedded, Distributed Fiber Dosimetry System for Space Applications

    by Arnaud Meyer, Adriana Morana, Martin Roche, Nourdine Kerboub, Julien Mekki, Gilles Mélin, Thierry Robin, André Champavère, Frédéric Saigné, Jérôme Boch, et al.

    A distributed dosimetry system based on phosphorus-doped optical fiber interrogated by an embedded Optical Time-Domain Reflectometer (OTDR) operated around 1610 nm is investigated for its performance, accuracy, repeatability and reliability in radiation environments corresponding to space applications. We analyzed the metrological properties of the system, showing an accuracy of ±6% on dose measurement using the minimum pulse width, and characterized the evolution of measurement uncertainty according to the sampling length. We demonstrated the system ability to measure Total Ionizing Dose under γ- and X-rays, at four dose rates ranging from 5.8 μGy(SiO2)/s to 5038 μGy(SiO2)/s, and with doses up to 344 Gy(SiO2). Finally, the device reliability under 350 MeV and 480 MeV proton irradiation was tested. No Single-Event Latchups (SEL) have been observed up to a fluence of ∼4.2×109 cm−2 and the Single-Event Functional Interrupt (SEFI) cross-section was on the order of ∼10-8 cm2, equivalent to ∼11.5 days in low Earth Orbit.


  • Physics-Based Ion Track Structure Model for Single-Event Effect Simulations on Power Devices

    by Manami Iwata, Satoshi Kuboyama, Alain Michez, Akiko Makihara, Misa Takahashi, Norio Nemoto, Masahiko Midorikawa, Jérôme Boch, Frédéric Saigné, Frédéric Wrobel, et al.

    A physics-based ion track structure was successfully established for ions covering a wide LET range applicable to single-event effect simulations on power devices by modeling the power law profile, which was derived from Geant4 simulation with MicroElec extension. The collected charge in two different types of SiC diodes calculated by the device simulator ECORCE is in good agreement with the experimental results at the low bias condition.