Propagation of Measurement Errors Through Body Composition Equations for Body Impedance Analysis
- 11 December 2013
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 63 (6) , 1535-1544
Abstract
In this paper, we present a framework to analyze the propagation of measurement errors through the body composition equations. This is done through the equations for body composition assessment (BCA), for single/multifrequency (SF, MF) body impedance analysis (BIA) approaches. We show that it is possible to estimate a priori the error variance on the BCA parameters from the error measurement in the weight, height, and impedance. The theoretical results are validated through the simulation and experimental data coming from the low-cost AFE4300 impedance spectrometer developed by Texas Instruments. This new spectrometer has been calibrated and characterized by performing measurements on phantoms and foot-to-foot body impedance measurements. The influence of the number of measurement frequencies on the accuracy of BCA is also studied for MF-BIA approach. Ultimately, the measurement error framework can be used to evaluate the suitability of an impedance system for BIA.Keywords
This publication has 21 references indexed in Scilit:
- A new measuring and identification approach for time-varying bioimpedance using multisine electrical impedance spectroscopyPhysiological Measurement, 2013
- An analog front-end enables electrical impedance spectroscopy system on-chip for biomedical applicationsPhysiological Measurement, 2008
- Measurements of total body water with a foot-to-foot impedancemeterMedical Engineering & Physics, 2007
- Body fluid volume determination via body composition spectroscopy in health and diseasePhysiological Measurement, 2006
- Determination of Cole parameters in multiple frequency bioelectrical impedance analysis using only the measurement of impedancesPhysiological Measurement, 2006
- Second generation mixture theory equation for estimating intracellular water using bioimpedance spectroscopyJournal of Applied Physiology, 2005
- Approaches to evaluate the virtual instrumentation measurement uncertaintiesIEEE Transactions on Instrumentation and Measurement, 2002
- Sources of error in bioimpedance spectroscopyPhysiological Measurement, 1998
- A Linear Kronig‐Kramers Transform Test for Immittance Data ValidationJournal of the Electrochemical Society, 1995
- Unproved prediction of extracellular and total body water using impedance loci generated by multiple frequency bioelectrical impedance analysisPhysics in Medicine & Biology, 1993