The Influence of Head and Neck Position on the Oropharyngeal Leak Pressure and Cuff Position of Three Supraglottic Airway Devices
Authors:
- Sung-Hee HanSHSung-Hee Han
- Sang-Hwan DoSDSang-Hwan Do
- Jung-Won KimJKJung-Won Kim
- Jin-Hee KimJKJin-Hee Kim
- 1 January 2009
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 108 (1) , 112-117
Abstract
With supraglottic airway devices, such as the laryngeal tube suction (LTS), ProSeal laryngeal mask airway (PLMA) and Cobra perilaryngeal airway (CobraPLA), oropharyngeal leak pressure or cuff position may vary according to changes in the position of the head and neck. We evaluated oropharyngeal leak pressure and cuff pressure of the PLMA, LTS, and CobraPLA in different head and neck positions. One-hundred-thirty-nine patients (aged 18-70 yr) scheduled for minor surgical procedures were randomly allocated to one of the supraglottic airway devices. Oropharyngeal leak pressure and cuff pressure were evaluated in four head and neck positions: neutral, 45 degrees of flexion, 45 degrees of extension, and 45 degrees of right rotation. Adverse events (i.e., difficulty in ventilation or gastric insufflation) were assessed during the study. Leak pressures of the PLMA were lowest in the extension (18.5 vs 23.9 and 26.8 cm H(2)O of LTS and CobraPLA, respectively; P < 0.001) and in the rotation position (25.0 vs 29.4 and 28.5 cm H(2)O of LTS and CobraPLA, respectively; P < 0.005). With the CobraPLA, gastric insufflations occurred before the oropharyngeal leak in 37 of 45 patients. There were ventilatory difficulties in seven patients with LTS after neck flexion, which required tracheal intubation. The PLMA showed significantly lower oropharyngeal leak pressures than did the LTS or CobraPLA in the neck extension and rotation positions. Caution is warranted when changing the position of the head and neck when using the Cobra-PLA or LTS as gastric insufflation or ventilatory difficulty may occur.Keywords
This publication has 21 references indexed in Scilit:
- A Randomized Controlled Trial Comparing the ProSeal™ Laryngeal Mask Airway with the Laryngeal Tube Suction in Mechanically Ventilated PatientsAnesthesiology, 2004
- The New Perilaryngeal Airway (CobraPLA™) Is as Efficient as the Laryngeal Mask Airway (LMA™) but Provides Better Airway Sealing PressuresAnesthesia & Analgesia, 2004
- Stability of the LMA-ProSeal® and standard laryngeal mask airway in different head and neck positions: a randomized crossover studyEuropean Journal of Anaesthesiology, 2003
- The ProSeal Laryngeal Mask AirwayAnesthesiology, 2000
- Comparison of four methods for assessing airway sealing pressure with the laryngeal mask airway in adult patientsBritish Journal of Anaesthesia, 1999
- The laryngeal mask airway for thyroid and parathyroid surgeryAnaesthesia, 1996
- Anaesthesia for Laser Pharyngoplasty—A Comparison of the Tracheal Tube with the Reinforced Laryngeal Mask AirwayAnaesthesia and Intensive Care, 1995
- Rotation of reinforced laryngeal mask airwayAnaesthesia, 1994
- The laryngeal mask airway in childrenAnaesthesia, 1991
- EFFECT OF GENERAL ANAESTHESIA ON THE PHARYNXBritish Journal of Anaesthesia, 1991