Toric outcomes: Computer-assisted registration versus intraoperative aberrometry
- 1 April 2017
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 43 (4) , 498-504
Abstract
To compare refractive outcomes of intraoperative computer-assisted registration and intraoperative aberrometry for the reduction of cylinder during toric intraocular lens (IOL) placement. Bowie Vision Institute, Bowie, Maryland, USA. Prospective randomized case series. The patients were divided into 2 groups that had toric IOL implantation after phacoemulsification. The intraoperative computer-assisted registration group (Group 1) had preoperative toric calculations. The aberrometry group (Group 2) was guided by a vergence formula and intraoperative pseudophakic cylindrical measurements to determine the final IOL power and intended orientation. The primary outcome measure was the mean postoperative remaining refractive astigmatism, and it was compared with the predicted amount of cylindrical correction with the IOL. Fifty-two patients (104 eyes) had sequential cataract surgery. The mean amount of cylinder correction was 1.60 diopters (D) ± 0.70 (SD) (range 0.75 to 3.08 D) in Group 1 and 1.74 ± 0.79 D (range 0.72 to 3.08 D) in Group 2. The mean remaining refractive astigmatism was -0.29 ± 0.22 D in Group 1 and -0.46 ± 0.25 D in Group 2 (P = .0003). A difference vector of 0.1 @ 87 degrees (0.31 D arithmetic mean) was calculated in Group 1 and 0.0 @ 82 degrees (0.44 D arithmetic mean) in Group 2. The correction index was 1.03 in Group 1 and 0.95 in Group 2. Intraoperative markerless computer-assisted registration and biometric guidance summarily yielded less remaining refractive cylinder than toric IOL placement guided by intraoperative aberrometry.Keywords
This publication has 23 references indexed in Scilit:
- Intraocular Lens Power Selection and Positioning With and Without Intraoperative AberrometryJournal of Refractive Surgery, 2015
- Corneal Topographic Astigmatism (CorT) to Quantify Total Corneal AstigmatismJournal of Refractive Surgery, 2015
- Software-Based Evaluation of Toric IOL Orientation in a Multicenter Clinical StudyJournal of Refractive Surgery, 2014
- Prospective Multicenter Study of Toric IOL Outcomes When Dual Zone Automated Keratometry Is Used for Astigmatism PlanningJournal of Refractive Surgery, 2013
- Contribution of posterior corneal astigmatism to total corneal astigmatismJournal of Cataract & Refractive Surgery, 2012
- New Axis-Marking Method for a Toric Intraocular Lens: Mapping MethodJournal of Refractive Surgery, 2011
- New intraocular lens for achromatizing the human eyeJournal of Cataract & Refractive Surgery, 2007
- Astigmatism analysis by the Alpins methodJournal of Cataract & Refractive Surgery, 2001
- New method of targeting vectors to treat astigmatismJournal of Cataract & Refractive Surgery, 1997
- Cyclotorsion in the seated and supine patientJournal of Cataract & Refractive Surgery, 1995