Success Rate of Motor Evoked Potentials for Intraoperative Neurophysiologic Monitoring: Effects of Age, Lesion Location, and Preoperative Neurologic Deficits
Authors:
- Djordje SterioDSDjordje Sterio
- Xu MingXMXu Ming
- Devaki D. ParaDPDevaki D. Para
- Marri ButusovaMBMarri Butusova
- Teresa TongTTTeresa Tong
- Aleksandar BericABAleksandar Beric
- 1 June 2007
- journal article
- research article
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 24 (3) , 281-285
Abstract
Summary: Transcranial electrical stimulation with myogenic motor evoked potential (MEP) recording was used for intraoperative neurophysiologic monitoring in 341 consecutive “high-risk” neurosurgical or orthopedic procedures. Overall, the success rate for establishing reliable MEP response was 94.8% for upper extremities and 66.6% for lower extremities. The rate was only 39.1% for lower extremities in patients with preoperative motor deficit and up to 81% in neurologically intact adults. Further analysis demonstrated that extremes of age or the presence of a lesion in the spinal cord and motor deficit contributed to failure in obtaining reliable MEPs.Keywords
This publication has 11 references indexed in Scilit:
- Transcranial Motor Evoked Potentials during Basilar Artery Aneurysm Surgery: Technique Application for 30 Consecutive PatientsNeurosurgery, 2004
- Intraoperative monitoring for tethered cord surgery: an updateNeurosurgical Focus, 2004
- Two cases of quadriparesis following anterior cervical discectomy, with normal perioperative somatosensory evoked potentialsJournal of Neurology, Neurosurgery & Psychiatry, 2003
- Safety of Intraoperative Transcranial Electrical Stimulation Motor Evoked Potential MonitoringJournal Of Clinical Neurophysiology, 2002
- Current Practice of Motor Evoked Potential Monitoring: Results of a SurveyJournal Of Clinical Neurophysiology, 2002
- “Threshold-level” multipulse transcranial electrical stimulation of motor cortex for intraoperative monitoring of spinal motor tracts: description of method and comparison to somatosensory evoked potential monitoringJournal of Neurosurgery, 1998
- Motor evoked potential monitoring during spinal surgery: responses of distal limb muscles to transcranial cortical stimulation with pulse trainsElectroencephalography and Clinical Neurophysiology/Evoked Potentials Section, 1996
- Somatosensory evoked potential spinal cord monitoring reduces neurologic deficits after scoliosis surgery: results of a large multicenter surveyElectroencephalography and Clinical Neurophysiology/Evoked Potentials Section, 1995
- Preservation of evoked potentials in a case of anterior spinal artery syndromeElectroencephalography and Clinical Neurophysiology/Evoked Potentials Section, 1990
- Anterior Spinal Fusion Complicated by ParaplegiaSpine, 1987