Design of starting a three phase induction motor using direct on-line, variable frequency drive, soft starting, and auto transformer methods
Open Access
- 1 February 2025
- journal article
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 37 (2) , 700-714
Abstract
The problem with 3-phase induction motors is that when starting the motor, the motor starting current can reach five to seven times the nominal current. This research compares slip, starting current, bus voltage, acceleration torque, motor torque, energy savings, and kVAR from the direct on-line (DOL), variable frequency drive (VFD), soft starting, and autotransformer starting methods in the electrical transient analyzer program (ETAP) software. This research result shows that the fastest VFD slip reaches a steady state, namely at 11+ seconds. The lowest starting/starting current is owned by the VFD method, namely <20% full load amps (FLA) in the first 2 seconds. The lowest decrease in bus voltage at steady state was experienced by the VFD method, namely 0.8152%. The quickest acceleration torque reaches a steady state in the VFD method, namely in 11+ seconds. The soft starting method owns the lowest starting torque, namely 20.75%. The soft starting method has the largest energy savings, namely 148.02 kW. Of the several variables observed, the best starting method is the VFD method.Keywords
This publication has 29 references indexed in Scilit:
- A Variable Inductor-Capacitor for Reactive Power Compensation2023
- Managing Inrush Current in A Variable Speed Drive Short Term Power Interruption Ride-Through Module2021
- Starting Induction Motor at Different Voltage Levels in the Electrical Power System2021
- Design of harmonic control and reactive power compensation scheme in a pipe fitting factory2021
- A novel simple method for elimination of DOL starting transient torque pulsations of three-phase induction motorsEngineering Science and Technology, an International Journal, 2021
- Comparison of three phase induction motor start using DOL, Star Delta and VSD Altivar61Journal of Physics: Conference Series, 2020
- Coupled autotransformer and magnetic‐control soft‐start method for super‐large‐capacity high‐voltage motorsHigh Voltage, 2020
- Adaptive soft starter for a three‐phase induction‐motor driving device using a multifunctional series compensatorIET Electric Power Applications, 2019
- Methods to reduce the starting current of an induction motor2017
- Application of acceleration method for evaluation of induction motor torque-speed characteristics2017