Nur Nabila Mohamed
Nur Nabila Mohamed has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Yulianta Siregar
Universitas Sumatera Utara
6 shared publications - Dedet Candra Riawan
Department of Electrical Engineering, Institut Teknologi Sepuluh Nopember, Surabaya, Indonesia
2 shared publications - Mohd Anuar Mat Isa
Information Security and Trusted Infrastructures Laboratory (InSTIL), Faculty of Electrical Engineering, Universiti Teknologi MARA, Shah Alam, Selangor, Malaysia
2 shared publications - Muldi Yuhendri
Universitas Negeri Padang
2 shared publications - Daniel Julian Sinaga
Department of Electrical Engineering Faculty of Engineering Universitas Sumatera Utara Medan Indonesia
1 shared publication - Farel Situmeang
Universitas Sumatera Utara
1 shared publication
Latest Publications
- Open Access
- 1 February 2026
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 15 (1) , 71-86
Design and analysis of hybrid filters for harmonic reduction in three-phase nonlinear rectifier loads
Rectifiers are included in the non-linear load category and can create resonance in a distribution network, which can be called harmonics. In a distribution network, rectifiers (non-linear loads) distort voltage and current harmonics, resulting in power losses and reduced power quality in the network. Harmonics in the distribution power grid cannot be eliminated, but can be reduced to values that can still be tolerated and evaluated until they are by the IEEE 519-2014 Standard. This research discusses reducing harmonic values in distribution networks designed in a simulation to implement a combination (hybrid) of series active and passive filters of the high pass and high pass type-C types. The results of research using the installation of high pass filters, type C filters, series active filters, hybrid-1 filters, and hybrid-2 filters, respectively, for each current total harmonic distortion (THD) value are 15.93%, 16.15%, 8.51%, 0.27%, and 0.25% where the current THD value when using the two hybrid filters is below the specified standard limit, namely 5%. By installing a hybrid filter, the harmonic value in each feeder is much better than installing a single series active filter, a high pass filter, and a type-C filter.
- 1 February 2026
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 15 (1) , 71-86
Open AccessDesign and analysis of hybrid filters for harmonic reduction in three-phase nonlinear rectifier loads
Rectifiers are included in the non-linear load category and can create resonance in a distribution network, which can be called harmonics. In a distribution network, rectifiers (non-linear loads) distort voltage and current harmonics, resulting in power losses and reduced power quality in the network. Harmonics in the distribution power grid cannot be eliminated, but can be reduced to values that can still be tolerated and evaluated until they are by the IEEE 519-2014 Standard. This research discusses reducing harmonic values in distribution networks designed in a simulation to implement a combination (hybrid) of series active and passive filters of the high pass and high pass type-C types. The results of research using the installation of high pass filters, type C filters, series active filters, hybrid-1 filters, and hybrid-2 filters, respectively, for each current total harmonic distortion (THD) value are 15.93%, 16.15%, 8.51%, 0.27%, and 0.25% where the current THD value when using the two hybrid filters is below the specified standard limit, namely 5%. By installing a hybrid filter, the harmonic value in each feeder is much better than installing a single series active filter, a high pass filter, and a type-C filter.
- Open Access
- 1 June 2025
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 15 (3) , 2567-2582
Comparative analysis of active filters, inductor-capacitor and inductor-capacitor-inductor passive filters in reducing harmonics
Control equipment at substations requires a rectifier to convert alternative current (AC)-direct current (DC) electric current to provide DC power for relays, motors for disconnector switches and power breaker switches, and telecommunications equipment. Rectifiers have non-linear load characteristics, which can result in a waveform that is not pure sinusoidal due to the interaction of fundamental frequency sinusoidal waves with other waves known as harmonics. Therefore, to not interfere with the equipment's work, a filter is needed to reduce the harmonics produced by the rectifier. In this research, using MATLAB/Simulink, prevention was carried out using active filters, inductor-capacitor (LC), and inductor-capacitor-inductor (LCL) passive filters (Ta, Tc, and Td designs) separately. After the research was carried out, it was found that the amount of harmonics before installing the filter was 49.61%. Then, after installing the active filter, the harmonics were reduced to 0.29%, the installation of the passive LC filter was reduced to 9.29%, and the installation of the LCL filter (Ta, Tc, and Td) became 1.44%, 0.29%, and 1.44%.
- 1 June 2025
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 15 (3) , 2567-2582
Open AccessComparative analysis of active filters, inductor-capacitor and inductor-capacitor-inductor passive filters in reducing harmonics
Control equipment at substations requires a rectifier to convert alternative current (AC)-direct current (DC) electric current to provide DC power for relays, motors for disconnector switches and power breaker switches, and telecommunications equipment. Rectifiers have non-linear load characteristics, which can result in a waveform that is not pure sinusoidal due to the interaction of fundamental frequency sinusoidal waves with other waves known as harmonics. Therefore, to not interfere with the equipment's work, a filter is needed to reduce the harmonics produced by the rectifier. In this research, using MATLAB/Simulink, prevention was carried out using active filters, inductor-capacitor (LC), and inductor-capacitor-inductor (LCL) passive filters (Ta, Tc, and Td designs) separately. After the research was carried out, it was found that the amount of harmonics before installing the filter was 49.61%. Then, after installing the active filter, the harmonics were reduced to 0.29%, the installation of the passive LC filter was reduced to 9.29%, and the installation of the LCL filter (Ta, Tc, and Td) became 1.44%, 0.29%, and 1.44%.
- Open Access
- 1 June 2025
- Published by Institute of Advanced Engineering and Science in International Journal of Applied Power Engineering (IJAPE)
- Vol. 14 (2) , 467-478
Generator analysis and comparison of working fluids in the organic Rankine cycle for biomass power plants using Aspen Plus software
The organic Rankine cycle utilizes low-temperature heat (flue heat) in power plants to produce electrical power. Several factors, including the working fluid's temperature and pressure, influence the efficiency of an organic Rankine cycle. This research method includes calculations using the gasification method in calculating electrical energy in PLTBM and calculating the experimental results of a series of organic Rankine cycles by taking into account the temperature and pressure of the working fluid using Aspen Plus Software, which is analyzed using statistical methods. The results of research using the gasification method in PLTBM fuel produced power of 27,279.38 MW/year for coconut shells, 6,489.66 MW/year for rice husks, and 532.62 MW/year for corn cobs. For the organic Rankine cycle series, rice husk waste produces the largest power of 8,336.67 kW, for coconut shells of 569,723.95 kW. For corn cobs of 358,639.63 with an efficiency value of organic working fluid in R-22 of 25.37% and the R-32 organic working fluid of 11.92% at a temperature of 125 °C in coconut shell waste, it can be concluded that the temperature of the working fluid has more influence on the efficiency of the organic Rankine cycle than the pressure of the working fluid.
- 1 June 2025
- Published by Institute of Advanced Engineering and Science in International Journal of Applied Power Engineering (IJAPE)
- Vol. 14 (2) , 467-478
Open AccessGenerator analysis and comparison of working fluids in the organic Rankine cycle for biomass power plants using Aspen Plus software
The organic Rankine cycle utilizes low-temperature heat (flue heat) in power plants to produce electrical power. Several factors, including the working fluid's temperature and pressure, influence the efficiency of an organic Rankine cycle. This research method includes calculations using the gasification method in calculating electrical energy in PLTBM and calculating the experimental results of a series of organic Rankine cycles by taking into account the temperature and pressure of the working fluid using Aspen Plus Software, which is analyzed using statistical methods. The results of research using the gasification method in PLTBM fuel produced power of 27,279.38 MW/year for coconut shells, 6,489.66 MW/year for rice husks, and 532.62 MW/year for corn cobs. For the organic Rankine cycle series, rice husk waste produces the largest power of 8,336.67 kW, for coconut shells of 569,723.95 kW. For corn cobs of 358,639.63 with an efficiency value of organic working fluid in R-22 of 25.37% and the R-32 organic working fluid of 11.92% at a temperature of 125 °C in coconut shell waste, it can be concluded that the temperature of the working fluid has more influence on the efficiency of the organic Rankine cycle than the pressure of the working fluid.
- Open Access
- 1 April 2025
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 15 (2) , 1396-1410
Comparison design of dynamic voltage restorers, distribution static compensators and unified power quality conditioner series shunts on voltage sag, and voltage swell
One issue with the power system is electrical power quality, which is brought on by short circuit disruptions and growing nonlinear loads. Power systems frequently have short circuits, resulting in voltage sags that can harm delicate loads. Voltage sage and swell issues can be resolved using unified power quality conditioner series shunts (UPQC-S), distribution static compensators (DSTATCOM), and dynamic voltage restorers (DVR). Custom power devices are very useful in overcoming problems with electrical networks. In this research, due to 3-phase short circuit faults, voltage sag and swell simulations were conducted using a load equal to 70% of the total load and a fault location point of 75% of the feeder length, from the results of research conducted with the case study PT. PLN (Persero) UP3 Sibolga Feeder SB 02 shows that DVR performs better than DSTATCOM and UPQC-S in handling voltage sag and voltage swell due to 3-phase short circuit disturbances. The DVR succeeded in providing the largest voltage sag recovery in phase C, increasing the voltage from 0.2481 pu to 0.9776 pu. The DVR is also effective in overcoming voltage swell on phase A, reducing it from 1.724 pu to 0.9969 pu.
- 1 April 2025
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 15 (2) , 1396-1410
Open AccessComparison design of dynamic voltage restorers, distribution static compensators and unified power quality conditioner series shunts on voltage sag, and voltage swell
One issue with the power system is electrical power quality, which is brought on by short circuit disruptions and growing nonlinear loads. Power systems frequently have short circuits, resulting in voltage sags that can harm delicate loads. Voltage sage and swell issues can be resolved using unified power quality conditioner series shunts (UPQC-S), distribution static compensators (DSTATCOM), and dynamic voltage restorers (DVR). Custom power devices are very useful in overcoming problems with electrical networks. In this research, due to 3-phase short circuit faults, voltage sag and swell simulations were conducted using a load equal to 70% of the total load and a fault location point of 75% of the feeder length, from the results of research conducted with the case study PT. PLN (Persero) UP3 Sibolga Feeder SB 02 shows that DVR performs better than DSTATCOM and UPQC-S in handling voltage sag and voltage swell due to 3-phase short circuit disturbances. The DVR succeeded in providing the largest voltage sag recovery in phase C, increasing the voltage from 0.2481 pu to 0.9776 pu. The DVR is also effective in overcoming voltage swell on phase A, reducing it from 1.724 pu to 0.9969 pu.
- Open Access
- 1 February 2025
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 37 (2) , 700-714
Design of starting a three phase induction motor using direct on-line, variable frequency drive, soft starting, and auto transformer methods
The problem with 3-phase induction motors is that when starting the motor, the motor starting current can reach five to seven times the nominal current. This research compares slip, starting current, bus voltage, acceleration torque, motor torque, energy savings, and kVAR from the direct on-line (DOL), variable frequency drive (VFD), soft starting, and autotransformer starting methods in the electrical transient analyzer program (ETAP) software. This research result shows that the fastest VFD slip reaches a steady state, namely at 11+ seconds. The lowest starting/starting current is owned by the VFD method, namely <20% full load amps (FLA) in the first 2 seconds. The lowest decrease in bus voltage at steady state was experienced by the VFD method, namely 0.8152%. The quickest acceleration torque reaches a steady state in the VFD method, namely in 11+ seconds. The soft starting method owns the lowest starting torque, namely 20.75%. The soft starting method has the largest energy savings, namely 148.02 kW. Of the several variables observed, the best starting method is the VFD method.
- 1 February 2025
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 37 (2) , 700-714
Open AccessDesign of starting a three phase induction motor using direct on-line, variable frequency drive, soft starting, and auto transformer methods
The problem with 3-phase induction motors is that when starting the motor, the motor starting current can reach five to seven times the nominal current. This research compares slip, starting current, bus voltage, acceleration torque, motor torque, energy savings, and kVAR from the direct on-line (DOL), variable frequency drive (VFD), soft starting, and autotransformer starting methods in the electrical transient analyzer program (ETAP) software. This research result shows that the fastest VFD slip reaches a steady state, namely at 11+ seconds. The lowest starting/starting current is owned by the VFD method, namely <20% full load amps (FLA) in the first 2 seconds. The lowest decrease in bus voltage at steady state was experienced by the VFD method, namely 0.8152%. The quickest acceleration torque reaches a steady state in the VFD method, namely in 11+ seconds. The soft starting method owns the lowest starting torque, namely 20.75%. The soft starting method has the largest energy savings, namely 148.02 kW. Of the several variables observed, the best starting method is the VFD method.
- Open Access
- 1 October 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 14 (5) , 4907-4920
Comparative design of harmonic current reduction in variable speed drive using space vector pulse width modulation and hybrid pulse width modulation
In industry and commerce, three-phase induction motors are frequently utilized as the primary power source for machinery. However, to increase motor performance efficiency, induction motors also need a tool for speed control. The variable speed drive (VSD) is one tool used to control the rotation speed of three-phase induction motors. Since VSD is a non-linear load, harmonic distortion will result from it. The space vector pulse width modulation (SVPWM) injection method and the hybrid pulse width modulation method were the two techniques employed by the author in this study to lower the current in the VSD. With the SVPWM injection approach, the variable speed drive's current total harmonic distortion (THD) values in the R, S, and T phases dropped to 3.77%, 3.53%, and 2.19% from 7.14%, 7.17%, and 7.58%.
- 1 October 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 14 (5) , 4907-4920
Open AccessComparative design of harmonic current reduction in variable speed drive using space vector pulse width modulation and hybrid pulse width modulation
In industry and commerce, three-phase induction motors are frequently utilized as the primary power source for machinery. However, to increase motor performance efficiency, induction motors also need a tool for speed control. The variable speed drive (VSD) is one tool used to control the rotation speed of three-phase induction motors. Since VSD is a non-linear load, harmonic distortion will result from it. The space vector pulse width modulation (SVPWM) injection method and the hybrid pulse width modulation method were the two techniques employed by the author in this study to lower the current in the VSD. With the SVPWM injection approach, the variable speed drive's current total harmonic distortion (THD) values in the R, S, and T phases dropped to 3.77%, 3.53%, and 2.19% from 7.14%, 7.17%, and 7.58%.
- 24 October 2018
- Published by Springer Nature in Telecommunication Systems
- Vol. 70 (4) , 511-523
Extending hybrid approach to secure Trivial File Transfer Protocol in M2M communication: a comparative analysis
- 24 October 2018
- Published by Springer Nature in Telecommunication Systems
- Vol. 70 (4) , 511-523
Extending hybrid approach to secure Trivial File Transfer Protocol in M2M communication: a comparative analysis
- 1 January 2017
- Published by Inderscience Publishers in International Journal of Electronic Security and Digital Forensics
- Vol. 9 (3) , 239
An automobile security protocol: side-channel security against timing and relay attacks
Keyless go, automotive keyless systems (AKS), passive keyless entry and start (PKES) are names given to smart systems that allow a driver to unlock a car without pressing any key, and drive the car without inserting a smart key for starting or stopping the car engine. It is one of the debutant IoT applications in automotive sector. This work presents a 128-bit pairing security protocol (PSP 128 bits) lightweight cryptographic protocol as a security protocol authentication between owner and car. The PSP 128 security analysis in timing and relay attacks by an adversary will be discussed and its resilience proved using a theoretical security reduction method. The theoretical security reduction results are supported by findings from an experimental test bed using RaspberryPi board and radio frequency (RF) communication. Based on the experiment results, the PSP 128 can support up to 56 thousand authentication sessions between owner and car per typical usage. It is estimated that a standard automotive battery running the device can have a lifespan of up to seven years with typical use.
- 1 January 2017
- Published by Inderscience Publishers in International Journal of Electronic Security and Digital Forensics
- Vol. 9 (3) , 239
An automobile security protocol: side-channel security against timing and relay attacks
Keyless go, automotive keyless systems (AKS), passive keyless entry and start (PKES) are names given to smart systems that allow a driver to unlock a car without pressing any key, and drive the car without inserting a smart key for starting or stopping the car engine. It is one of the debutant IoT applications in automotive sector. This work presents a 128-bit pairing security protocol (PSP 128 bits) lightweight cryptographic protocol as a security protocol authentication between owner and car. The PSP 128 security analysis in timing and relay attacks by an adversary will be discussed and its resilience proved using a theoretical security reduction method. The theoretical security reduction results are supported by findings from an experimental test bed using RaspberryPi board and radio frequency (RF) communication. Based on the experiment results, the PSP 128 can support up to 56 thousand authentication sessions between owner and car per typical usage. It is estimated that a standard automotive battery running the device can have a lifespan of up to seven years with typical use.