High-Power Millimeter-Wave Dummy Load Reflected Power Measurement Method Based on a Time-Domain Gate
- 8 December 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 51 (1) , 77-82
Abstract
This article presents a low-power measurement method for the reflected power of a high-power millimeter-wave dummy load. The proposed method extracts the unknown S-parameters of the fixtures and the dummy load by combining frequency-and time-domain S-parameters. In this way, it partially eliminates the effects of asymmetric fixtures. Experiments and error source analysis of the proposed method are carried out.Keywords
Funding Information
- National Natural Science Foundation (12175217)
- State Administration of Science, Technology and Industry for Nation Defense of China, Technology Foundation Project (JSJL2021212B003, JSJL2019212B006)
This publication has 12 references indexed in Scilit:
- Validation Experiments on the 2-MW CW 170-GHz Load for the European ITER GyrotronIEEE Transactions on Plasma Science, 2017
- Development of a dummy load and waveguide components for 1 MW CW gyrotronFusion Engineering and Design, 2016
- Recent Advances on the Spherical Tokamak Route to Fusion PowerIEEE Transactions on Plasma Science, 2014
- Design and Operation of a 2-MW CW RF Load for GyrotronsIEEE Transactions on Electron Devices, 2014
- A new CW-load for high power ECRH systems2011
- Characterizations of asymmetric fixtures with a two-gate approach2011
- A Review on the Applications of High Power, High Frequency Microwave Source: GyrotronJournal of Fusion Energy, 2011
- High Power Gyro-Devices for Plasma Heating and Other ApplicationsInternational Journal of Infrared and Millimeter Waves, 2005
- Design of a high-power load for millimetre-wave Gaussian beamsNuclear Fusion, 2003
- TESTS OF COMPACT DUMMY LOADS DESIGNED FOR 1 MW-CW2003