Abstract
Introduction: The incidence of cardiac implantable electronic device (CIED) infections is increasing. Complete device and lead removal are recommended for all patients with definite CIED system infection. In patients with pacemaker dependency, temporary pacing before reimplantation is necessary. In this study, temporary pacing using active fixation leads (TPAFL) was evaluated.Methods: We reviewed data from consecutive patients implanted with TPAFL after transvenous lead extraction at our center between November 2014 and October 2020.Results: TPAFL were placed in 334 patients. The mean age was 64.5 ± 16.4 years and 76.3% were males. Two hundred and forty (72%) were treated due to local pocket infection and 94 (28%) systemic infection. The indication for temporary pacing was sick sinus syndrome in 135 (40.4%) patients and complete or high‐grade atrioventricular (AV) block in 199 (59.6%) patients. The most common access site for lead implantation was the ipsilateral subclavian or axillary vein (78.9%). A new permanent CIED was reimplanted at 10.3 ± 9.2 days (median 10, range: 2–70) after implantation of the temporary pacing. There were five (1.5%) adverse events related to the temporary pacing during hospitalization. The median follow‐up duration was 23.1 months (interquartile range [IQR], 7.2–43.4 months). Only one patient (0.3%) developed recurrent CIED infection.Conclusion: TPAFL is safe and effective in pacemaker‐dependent patients after infected CIED removal. The rate of temporary pacing‐related complications, including lead dislodgment and reinfection of CIED is relatively low.Keywords
This publication has 13 references indexed in Scilit:
- Prevalence and predictor factors of severe venous obstruction after cardiovascular electronic device implantationEP Europace, 2015
- Reuse of Infected Cardiac Rhythm Management Devices in the Same Patients: A Single-Center ExperiencePacing and Clinical Electrophysiology, 2014
- Utility and safety of temporary pacing using active fixation leads and externalized re-usable permanent pacemakers after lead extractionEP Europace, 2013
- Transcutaneous lead implantation connected to an externalized pacemaker in patients with implantable cardiac defibrillator/pacemaker infection and pacemaker dependencyEP Europace, 2013
- 16-Year Trends in the Infection Burden for Pacemakers and Implantable Cardioverter-Defibrillators in the United StatesJACC, 2011
- The 11th World Survey of Cardiac Pacing and Implantable Cardioverter‐Defibrillators: Calendar Year 2009–A World Society of Arrhythmia's ProjectPacing and Clinical Electrophysiology, 2011
- Continued Rise in Rates of Cardiovascular Implantable Electronic Device Infections in the United States: Temporal Trends and Causative InsightsPacing and Clinical Electrophysiology, 2010
- Utility and Cost Effectiveness of Temporary Pacing Using Active Fixation Leads and an Externally Placed Reusable Permanent PacemakerThe American Journal of Cardiology, 2006
- Percutaneous Lead Implantation Connected to an External Device in Stimulation‐Dependent Patients with Systemic Infection—A Prospective and Controlled StudyPacing and Clinical Electrophysiology, 2006
- Rising Rates of Cardiac Rhythm Management Device Infections in the United States: 1996 through 2003JACC, 2006