ACPSEM position paper: recommendations for a digital general X-ray quality assurance program
Authors:
Open Access
- 12 August 2024
- journal article
- research article
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 47 (3) , 789-812
Abstract
This guideline has been prepared by the ACPSEM to provide a standardised quality assurance program to be used within General X-ray imaging environments. The guideline includes the responsibilities of various multidisciplinary team members within medical imaging facilities. It must be noted that the listed tests and testing frequencies are not intended to replace or become regulatory requirements. Implementing a quality assurance program as outlined in this position paper is there to ensure best practice for imaging facilities by providing a framework to establish and monitor correct equipment performance. The current document has been produced through an extensive review of current international practices and local experience within the Australasian healthcare environment. Due to the constant evolution of digital radiographic equipment, there is no current consensus in international quality assurance guidelines as they continue to be adapted and updated. This document describes the current state of the use of digital General X-ray equipment in the Australasian environment and provides recommendations of test procedures that may be best suited for the current medical imaging climate in Australasia. Due to the everchanging developments in the medical imaging environment and the ability of new technologies to perform more complex tasks it is believed that in the future this document will be further reviewed in the hopes of producing a more globally agreed upon standard quality assurance program. Any such adjustments that are deemed to be necessary to Version 1.0 of this document will be provided in electronic format on the ACPSEM website with a notification to all parties involved in the use of digital General X-ray equipment. This guideline does not provide detailed methodologies for all the quality control tests recommended as it is it is expected that the professionals implementing aspects of this quality assurance program have the working knowledge and access to appropriate resources to develop testing methodologies appropriate for their local imaging environment.Keywords
This publication has 10 references indexed in Scilit:
- Practical application of AAPM Report 270 in display quality assurance: A report of Task Group 270Medical Physics, 2020
- Benchmarking the performance of fixed-image receptor digital radiography systems. Part 2: system performance metricAustralasian Physics & Engineering Sciences in Medicine, 2016
- Temporal stability of digital radiographic detectorsAustralasian Physics & Engineering Sciences in Medicine, 2016
- Medical Electrical Equipment-Part 1-3: General Requirements for Basic Safety and Essential Performance-Collateral Standard : Radiation Protection in Diagnostic X-ray Equipment JIS T 0601-1-3Japanese Journal of Radiological Technology, 2009
- One Year’s Results from a Server-Based System for Performing Reject Analysis and Exposure Analysis in Computed RadiographyJournal of Digital Imaging, 2009
- Digital Radiography Reject Analysis: Data Collection Methodology, Results, and Recommendations from an In-depth Investigation at Two HospitalsJournal of Digital Imaging, 2008
- Digital Repeat Analysis; Setup and OperationJournal of Digital Imaging, 2006
- Is Reject Analysis Necessary after Converting to Computed Radiography?Journal of Digital Imaging, 2002
- Comparative reject analysis in conventional film-screen and digital storage phosphor radiographyEuropean Radiology, 1999