Quiet and distortion‐free, whole brain BOLD fMRI using T2‐prepared RUFIS
Open Access
- 12 May 2015
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 75 (4) , 1402-1412
Abstract
Purpose: To develop and evaluate a novel MR method that addresses some of the most eminent technical challenges of current BOLD‐based fMRI in terms of 1) acoustic noise and 2) geometric distortions and signal dropouts.Methods: A BOLD‐sensitive fMRI pulse sequence was designed that first generates T2‐weighted magnetization (using a T2 preparation module) and subsequently undergoes three‐dimensional (3D) radial encoding using a rotating ultrafast imaging sequence (RUFIS). The method was tested on healthy volunteers at 3T with motor, visual, and auditory tasks, and compared relative to standard gradient and spin echo planar imaging (EPI) methods.Results: In combination with parallel imaging the method achieves efficient and robust 3D whole brain coverage (3 mm isotropic resolution in 2.65 s scan time). Compared with standard EPI‐based fMRI, the method demonstrated 1) T2‐weighted imaging clean of geometrical distortions and signal dropout, 2) an acoustic noise reduction of ∼40 dB(A), and 3) a consistent BOLD response that is less sensitive (∼1.3% BOLD change) but spatially more specific.Conclusion: T2‐prepared RUFIS provides quiet and distortion‐free whole brain BOLD fMRI with minimal demands on the gradient performance. In particular, auditory fMRI and/or studies involving brain regions near air–tissue interfaces are expected to greatly benefit from the proposed method, especially if performed at ultrahigh field strengths. Magn Reson Med 75:1402–1412, 2016. © 2015 Wiley Periodicals, Inc.Keywords
Funding Information
- PRONIA (funded by the European Commission within the 7th Framework Programme) (602152)
This publication has 73 references indexed in Scilit:
- In situ active control of noise in a 4 T MRI scannerJournal of Magnetic Resonance Imaging, 2011
- Temporal SNR characteristics in segmented 3D‐EPI at 7TMagnetic Resonance in Medicine, 2011
- Vascular contributions to pattern analysis: Comparing gradient and spin echo fMRI at 3TNeuroImage, 2011
- Evaluating an acoustically quiet EPI sequence for use in fMRI studies of speech and auditory processingNeuroImage, 2010
- Three dimensional echo-planar imaging at 7 TeslaNeuroImage, 2010
- Multiband multislice GE‐EPI at 7 tesla, with 16‐fold acceleration using partial parallel imaging with application to high spatial and temporal whole‐brain fMRIMagnetic Resonance in Medicine, 2010
- T2-weighted 3D fMRI usingS2-SSFP at 7 teslaMagnetic Resonance in Medicine, 2010
- Improvements in parallel imaging accelerated functional MRI using multiecho echo-planar imagingMagnetic Resonance in Medicine, 2010
- Bone matrix imaged in vivo by water‐ and fat‐suppressed proton projection MRI (WASPI) of animal and human subjectsJournal of Magnetic Resonance Imaging, 2010
- Functional neuroimaging correlates of finger-tapping task variations: An ALE meta-analysisNeuroImage, 2008