Continuous Glucose Monitoring Sensor Glucose Levels and Insulin Pump Infusion Set Wear-Time During Treatment with Fast-Acting Insulin Aspart: A Post Hoc Analysis of Onset 5
Open Access
- 5 January 2022
- journal article
- research article
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 24 (1) , 10-17
Abstract
Background: In the onset 5 trial, fast-acting insulin aspart (faster aspart) was noninferior to insulin aspart (IAsp) for change from baseline glycated hemoglobin at 16 weeks, when used in continuous subcutaneous insulin infusion by participants with type 1 diabetes. The aim of this post hoc analysis was to investigate whether infusion set wear-time was associated with changes in sensor glucose, measured using continuous glucose monitoring (CGM). Materials and Methods: This was a post hoc analysis of onset 5 data. Mean infusion set wear-time and duration of CGM-wearing period were assessed. Mean CGM sensor glucose 24 h before and 24 h after were used to calculate the before–after difference (CGM sensor glucose drift). Results: Mean infusion set wear-time was 2.9 and 3.0 days in the faster aspart and IAsp arms, respectively. At 16 weeks, the average duration of the CGM wearing period was 13.7 and 13.8 days, respectively. Mean CGM sensor glucose before versus after an infusion set change, at week 16, was 10.14 versus 9.39 mmol/L with faster aspart and 9.48 versus 9.47 mmol/L with IAsp. The estimated treatment difference in CGM sensor glucose drift at 16 weeks for faster aspart versus IAsp was +0.72 mmol/L (95% confidence interval: 0.48–0.96, P < 0.001). Conclusions: Mean infusion set wear-time and duration of CGM-wearing period were similar for faster aspart and IAsp. A significantly greater upward drift in CGM sensor glucose values measured during an infusion set wearing period was observed with faster aspart versus IAsp. Clinical trial registration: NCT02825251.Keywords
This publication has 14 references indexed in Scilit:
- Advances in technology for management of type 1 diabetesThe Lancet, 2019
- Elucidating the Mechanism of Absorption of Fast-Acting Insulin Aspart: The Role of NiacinamidePharmaceutical Research, 2019
- A randomized, multicentre trial evaluating the efficacy and safety of fast‐acting insulin aspart in continuous subcutaneous insulin infusion in adults with type 1 diabetes (onset 5)Diabetes, Obesity and Metabolism, 2018
- A Pooled Analysis of Clinical Pharmacology Trials Investigating the Pharmacokinetic and Pharmacodynamic Characteristics of Fast-Acting Insulin Aspart in Adults with Type 1 DiabetesClinical Pharmacokinetics, 2017
- Effect of Continuous Glucose Monitoring on Glycemic Control in Adults With Type 1 Diabetes Using Insulin InjectionsJAMA, 2017
- Improved Postprandial Glycemic Control with Faster-Acting Insulin Aspart in Patients with Type 1 Diabetes Using Continuous Subcutaneous Insulin InfusionDiabetes Technology & Therapeutics, 2017
- Pharmacological properties of faster‐acting insulin aspart vs insulin aspart in patients with type 1 diabetes receiving continuous subcutaneous insulin infusion: A randomized, double‐blind, crossover trialDiabetes, Obesity and Metabolism, 2016
- Effect of Insulin Catheter Wear-Time on Subcutaneous Adipose Tissue Blood Flow and Insulin Absorption in HumansDiabetes Technology & Therapeutics, 2009
- Hypoglycemia with Intensive Insulin Therapy: A Systematic Review and Meta-Analyses of Randomized Trials of Continuous Subcutaneous Insulin Infusion Versus Multiple Daily InjectionsThe Journal of Clinical Endocrinology & Metabolism, 2009
- Effect of Age of Infusion Site and Type of Rapid-Acting Analog on Pharmacodynamic Parameters of Insulin Boluses in Youth With Type 1 Diabetes Receiving Insulin Pump TherapyDiabetes Care, 2009