Concurrent fNIRS-fMRI measurement to validate a method for separating deep and shallow fNIRS signals by using multidistance optodes
Open Access
- 1 January 2015
- journal article
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 2 (1) , 015003
Abstract
It has been reported that a functional near-infrared spectroscopy (fNIRS) signal can be contaminated by extracerebral contributions. Many algorithms using multidistance separations to address this issue have been proposed, but their spatial separation performance has rarely been validated with simultaneous measurements of fNIRS and functional magnetic resonance imaging (fMRI). We previously proposed a method for discriminating between deep and shallow contributions in fNIRS signals, referred to as the multidistance independent component analysis (MD-ICA) method. In this study, to validate the MD-ICA method from the spatial aspect, multidistance fNIRS, fMRI, and laser-Doppler-flowmetry signals were simultaneously obtained for 12 healthy adult males during three tasks. The fNIRS signal was separated into deep and shallow signals by using the MD-ICA method, and the correlation between the waveforms of the separated fNIRS signals and the gray matter blood oxygenation level–dependent signals was analyzed. A three-way analysis of variance () indicated that the main effect of fNIRS signal depth on the correlation is significant [, ]. This result indicates that the MD-ICA method successfully separates fNIRS signals into spatially deep and shallow signals, and the accuracy and reliability of the fNIRS signal will be improved with the method.
Keywords
Funding Information
- Scientific Research on Innovative Areas (23118001)
- Scientific Research on Innovative Areas (23118004)
- Adolescent Mind & Self-Regulation to KK (32118003)
- Young Scientists (23791309)
- Young Scientists (26860914)
- Scientific Research (23390286)
- Challenging Exploratory Research (22659209)
This publication has 64 references indexed in Scilit:
- Cutaneous Vasoconstriction Affects Near-infrared Spectroscopy Determined Cerebral Oxygen Saturation during Administration of NorepinephrineAnesthesiology, 2012
- Relationship of negative mood with prefrontal cortex activity during working memory tasks: An optical topography studyNeuroscience Research, 2011
- Two-detector Corrected Near Infrared Spectroscopy (C-NIRS) detects hemodynamic activation responses more robustly than single-detector NIRSNeuroImage, 2011
- Correlation of within-individual fluctuation of depressed mood with prefrontal cortex activity during verbal working memory task: optical topography studyJournal of Biomedical Optics, 2011
- Development of wearable optical topography system for mapping the prefrontal cortex activationReview of Scientific Instruments, 2009
- Investigation of Frontal Cortex, Motor Cortex and Systemic Haemodynamic Changes During Anagram Solving2008
- Extracting task-related activation components from optical topography measurement using independent components analysisJournal of Biomedical Optics, 2008
- Circulatory basis of fMRI signals: relationship between changes in the hemodynamic parameters and BOLD signal intensityNeuroImage, 2004
- Clinical Evaluation of Near-Infrared Spectroscopy for Testing Cerebrovascular Reactivity in Patients With Carotid Artery DiseaseStroke, 1997
- Estimation of optical pathlength through tissue from direct time of flight measurementPhysics in Medicine & Biology, 1988