Corrosion Analysis of PMEDM-Modified Ti6Al4V Surfaces: Insights from Potentiodynamic Measurements, Ion Release, KPFM and Crevice Corrosion Evaluation
Authors:
- Adrian BuchholzABAdrian Buchholz
- Vadym VoropaiVVVadym Voropai
- Viet-Duc BuiVBViet-Duc Bui
- Andre MartinAMAndre Martin
- Thomas BergerTBThomas Berger
- Mostafa MohamedMMMostafa Mohamed
- Corina AndronescuCACorina Andronescu
- Joachim DöringJDJoachim Döring
- Janosch SchoonJSJanosch Schoon
- Andreas SchubertASAndreas Schubert
- Jessica BertrandJessica Bertrand
Preprint
- 7 September 2026
- preprint
- Published by Elsevier in SSRN Electronic Journal
Abstract
It has been shown that the incorporation of silver into the surface of a titanium alloy (Ti6Al4V) by powder mixed electrical discharge machining (PMEDM) exhibits an antiadhesive effect against Staphylococcus spp.. This study aims to investigate the electrochemical performance of this modified surface under simulated physiological conditions, mimicking in vivo corrosion-inducing conditions. Electrochemical behavior was analyzed using potentiodynamic polarization measurements, Kelvin probe fore microscope (KPFM) measurements and ion release quantification, while crevice-corrosion mechanisms were evaluated retrospectively by scanning electron microscopy and energy-dispersive X-ray spectroscopy.Corrosion current density showed an inverse association with PMEDM discharge energy, while neither silver content in the modified zone nor the open-circuit potential exhibited a significant association with corrosion activity. Crevice exposure led to Ti-rich, O-poor deposits at the inner end consistent with hydride formation and localized Ag-associated microgalvanic pitting corrosion were observed; which could be confirmed by local Volta potential differences in KPFM measurements. However, no widespread material degradation or propagating crevice corrosion was observed under the investigated conditions. Metal quantification revealed higher absolute release of alloying elements from the rougher PMEDM surfaces and an increase in the Ag release with the Ag content on the surface; the measured released Ag levels were within ranges regarded as antibacterial.Together, these findings indicate that PMEDM processing parameters influence the global electrochemical response, whereas Ag (particles) primarily affect localized surface mechanisms and Ag ion release. Under the investigated conditions, no correlation between Ag and corrosion current nor widespread surface degradation was detected, which could be translated into independent adaptation options for both electrochemical performance (based on discharge energy) and antibacterial properties (based on Ag content).Keywords
This publication has 62 references indexed in Scilit:
- Metal Concentrations in Blood and Cerebrospinal Fluid of Patients With Arthroplasty ImplantsJAMA Network Open, 2025
- Microstructure‐dependent crevice corrosion damage of implant materials CoCr28Mo6, TiAl6V4 and REX 734 under severe inflammatory conditionsJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2022
- The projected volume of primary and revision total knee arthroplasty will place an immense burden on future health care systems over the next 30 yearsKnee Surgery, Sports Traumatology, Arthroscopy, 2020
- Corrosion of the Head-Stem Taper Junction—Are We on the Verge of an Epidemic?HSS Journal®: The Musculoskeletal Journal of Hospital for Special Surgery, 2016
- Potential release of in vivo trace metals from metallic medical implants in the human body: From ions to nanoparticles – A systematic analytical reviewActa Biomaterialia, 2014
- The influence of cathodic polarization and simulated inflammation on titanium electrochemistryJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2014
- In vivo severe corrosion and hydrogen embrittlement of retrieved modular body titanium alloy hip‐implantsJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2008
- Hydride formation under cathodic charging of titanium and TiAl-based alloys in alkaline solutionsMaterials Science, 2008
- A comparison of the surface characteristics and ion release of Ti6Al4V and heat-treated Ti6Al4VJournal of Biomedical Materials Research, 2000
- In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy couplingJournal of Biomedical Materials Research, 1993