Effect of intracardiac blood flow pulsatility during radiofrequency cardiac ablation: computer modeling study
Open Access
- 1 January 2021
- journal article
- research article
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 38 (1) , 316-325
Abstract
To assess the effect of intracardiac blood flow pulsatility on tissue and blood distributions during radiofrequency (RF) cardiac ablation (RFCA). A three-dimensional computer model was used to simulate constant power ablations with an irrigated-tip electrode and three possible catheter orientations (perpendicular, parallel and 45°). Continuous flow and three different pulsatile flow profiles were considered, with four average blood velocity values: 3, 5.5, 8.5 and 24.4 cm/s. The 50 °C contour was used to assess thermal lesion size. The differences in lesion size between continuous flow and the different pulsatile flow profiles were always less than 1 mm. As regards maximum tissue temperature, the differences between continuous and pulsatile flow were always less than 1 °C, with slightly higher differences in maximum blood temperature, but never over 6 °C. While the progress of maximum tissue temperature was identical for continuous and pulsatile flow, maximum blood temperature with the pulsatile profile showed small amplitude oscillations associated with blood flow pulsatility. The findings show that intracardiac blood pulsatility has a negligible effect on lesion size and a very limited impact on maximum tissue and blood temperatures, which suggests that future experimental studies based on ex vivo or in silico models can ignore pulsatility in intracardiac blood flow.Keywords
This publication has 26 references indexed in Scilit:
- Should fluid dynamics be included in computer models of RF cardiac ablation by irrigated-tip electrodes?BioMedical Engineering OnLine, 2018
- Left Atrial 4D Blood Flow Dynamics and Hemostasis following Electrical Cardioversion of Atrial FibrillationFrontiers in Physiology, 2017
- Comparative Analysis of Different Methods of Modeling the Thermal Effect of Circulating Blood Flow During RF Cardiac AblationIEEE Transactions on Biomedical Engineering, 2015
- Effect of electrode thermal conductivity in cardiac radiofrequency catheter ablation: A computational modeling studyInternational Journal of Hyperthermia, 2009
- High Incidence of Thrombus Formation Without Impedance Rise During Radiofrequency Ablation Using Electrode Temperature ControlPacing and Clinical Electrophysiology, 2003
- Guidelines for predicting lesion size at common endocardial locations during radio-frequency ablationIEEE Transactions on Biomedical Engineering, 2001
- In Vitro Temperature Map of Cardiac Ablation Demonstrates the Effect of Flow on Lesion DevelopmentAnnals of Biomedical Engineering, 2000
- A Three-Dimensional Finite Element Model of Radiofrequency Ablation with Blood Flow and its Experimental ValidationAnnals of Biomedical Engineering, 2000
- Temperature measurement within myocardium during in vitro RF catheter ablationIEEE Transactions on Biomedical Engineering, 2000
- Pulmonary venous flow pattern--its relationship to cardiac dynamics. A pulsed Doppler echocardiographic study.Circulation, 1985